CoChat

Characteristics of flow-mediated brachial artery vasodilation in human subjects.

Sinoway, L I, Hendrickson, C, Davidson, W R, Prophet, S, Zelis, R · 1989 · Circulation Research
Cited by 135

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

In an effort to determine whether arterial conductance vessels dilate in response to increased blood flow stimuli, brachial artery area (cm2) and diameter (cm) were derived by simultaneous measurement of forearm blood flow (ml/min.100 ml) and brachial artery blood flow velocity (cm/sec) following the release of arterial occlusion. Measurements were made at rest and at the time of maximal flow after the release of graded periods of forearm arterial occlusion (20 seconds to 10 minutes). These studies showed a graded large vessel dilation following occlusions of up to 1 minute (baseline diameter, 0.33 +/- 0.01; after 1 minute occlusion, 0.45 +/- 0.02 cm; p less than 0.05) after which time diameter plateaued (after 10 minutes of occlusion, 0.48 +/- 0.02 cm). In addition, the time course of diameter and flow changes after 3 minutes of arterial occlusion were examined. Flow was maximal at 5 seconds but diameter was maximal at 15-30 seconds after release. Furthermore, the half time for the return of diameter to baseline was longer than that for blood flow. We also measured the diameter after forearm heating (42 degrees C) and noted a substantial increase in diameter (before heating, 0.32 +/- 0.01; after heating, 0.39 +/- 0.02 cm; p less than 0.05). Finally, we applied pressure to the venous side of arteriovenous fistulae in five hemodialysis patients. This maneuver was associated with large reductions in forearm blood flow (baseline flow, 63.3 +/- 10.6; venous compression flow, 36.0 +/- 4.4 ml/min.100 ml; p less than 0.05) and a decrease in brachial artery size (baseline diameter, 0.63 +/- 0.07; venous compression diameter, 0.58 +/- 0.06 cm; p less than 0.05). We conclude that 1) the human brachial artery size changes in response to changes in blood flow, and 2) the maximal dilation occurs after maximal flow is noted. Although alternate explanations are possible for each of our observations, our results are most consistent with a flow-mediated, localized vasodilating process.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.64.1.32

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 135

Metadata

Authors
Sinoway, L. I., Hendrickson, C., Davidson, W. R., Prophet, S., & Zelis, R.
Venue
Circulation Research
Published
1989-01
Volume
64
Issue
1
Pages
32-42
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2139654614
Cited by
135
References
1
FWCI
2.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.