The DOI matches its Crossref record.
Hemodynamics of the stage 12 to stage 29 chick embryo.
Abstract
The heart is the first functioning organ in the embryo and provides blood flow during cardiac morphogenesis from a muscle-wrapped tube a few cells thick to the four-chambered pump. We described the hemodynamics of the chick embryo from stage 12 (50 hours of a 21-day incubation) to stage 29 (6 days), during which the embryo weight increased 120-fold. We measured ventricular, embryo and extraembryonic vascular bed wet weights, dorsal aortic blood flow with a directional pulsed-Doppler velocity meter, and ventricular and vitelline arterial blood pressures with a servo-null micropressure system. The data are reported as mean +/- SEM. With rapid development and morphogenesis, dorsal aortic blood flow increased from 0.015 +/- 0.004 to 2.40 +/- 0.20 mm3/sec parallel to the geometric increase of wet embryo weight from 2.22 +/- 0.10 to 267.5 +/- 9.7 mg. Dorsal aortic blood flow normalized for embryo and extraembryonic weight remained relatively constant (Y = 2.13 + 0.02X, r = 0.23, SEE = 0.03). Stroke volume increased from 0.01 +/- 0.003 to 0.69 +/- 0.03 mm3, and heart rate doubled from 103 +/- 2 to 208 +/- 5 beats/min. Systolic, diastolic, and mean vitelline arterial pressure increased linearly from 0.32 +/- 0.01, 0.23 +/- 0.01, and 0.28 +/- 0.01 mm Hg at stage 12 to 2.00 +/- 0.06, 1.22 +/- 0.03, and 1.51 +/- 0.04 mm Hg, respectively, at stage 29. Ventricular peak systolic and end-diastolic pressure increased from 0.95 +/- 0.04 and 0.24 +/- 0.02 at stage 12 to 3.45 +/- 0.10 and 0.82 +/- 0.03 at stage 29, respectively. The hemodynamic waveforms were similar to those found in the four-chamber heart of the mature animal. These data are integral to understanding the interrelation of function and form during cardiac development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Structure and function of the developing zebrafish heart
Hu, N., Sedmera, D., Yost, H. J., & Clark, E. B. (2000) · The Anatomical Record · doi:10.1002/1097-0185(20001001)260:2<148::aid-ar50>3.0.co;2-x · Cited by 314
Self-citationDevelopmental Biology of the Vascular Smooth Muscle Cell: Building a Multilayered Vessel Wall
Hungerford, J., & Little, C. (1999) · Journal of Vascular Research · doi:10.1159/000025622 · Cited by 295
Mechanical regulation of cardiac development
Lindsey, S. E. (2014) · Frontiers in Physiology · doi:10.3389/fphys.2014.00318 · Cited by 159
Biomechanics of early cardiac development
Goenezen, S., Rennie, M. Y., & Rugonyi, S. (2012) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-012-0414-7 · Cited by 94
Hemodynamic patterning of the avian atrioventricular valve
Yalcin, H. C., Shekhar, A., McQuinn, T. C., & Butcher, J. T. (2011) · Developmental Dynamics · doi:10.1002/dvdy.22512 · Cited by 72
Metadata
- Authors
- Hu, N., & Clark, E. B.
- Venue
- Circulation Research
- Published
- 1989-12
- Volume
- 65
- Issue
- 6
- Pages
- 1665-1670
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2097208375
- Cited by
- 213
- References
- 0
- FWCI
- 1.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hemodynamics of the stage 12 to stage 29 chick embryo. https://app.cochat.ai/papers/10.1161/01.res.65.6.1665
- The paper
- Hu, N., & Clark, E. B. (1989). Hemodynamics of the stage 12 to stage 29 chick embryo. Circulation Research. https://doi.org/10.1161/01.res.65.6.1665
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.