Patterned growth of neonatal rat heart cells in culture. Morphological and electrophysiological characterization.
The DOI matches its Crossref record.
Abstract
A culture method was developed that permits patterning of the growth of ventricular myocytes of neonatal rats. Regions were created on the culture substrate that either prevented (photoresist coat) or supported (glass surface) attachment of cells. In this way the geometry of interconnecting growth channels could be specified. Single-layered myocyte strands of variable length and with widths of as little as 65 micron (three to four cells wide) were obtained. The shape and orientation of the individual myocytes were a function of growth-channel width: the narrower the channel, the more elongated the cells and the more likely was the long axis to be oriented along the channel axis. In channels with width of 100 micron or less, cells were aligned longitudinally and cross-striated as in vivo. A high degree of morphological cell differentiation required the presence of contractile activity. Maximal diastolic potential (-71 mV), action potential amplitude (93 mV), and maximal upstroke velocity (140 V/sec) did not change with increasing culture age. Mean longitudinal conduction velocity was 0.39 m/sec. No electrophysiological or morphological evidence of photoresist toxicity was seen, and the data indicate a high degree of cell differentiation in the patterned cell cultures. The method thus is suitable for the study of the relation between impulse propagation and structure at a cellular level in artificial networks of predefined shape.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Advances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
Microengineering of Cellular Interactions
Folch, A., & Toner, M. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.227 · Cited by 602
Controlling cell interactions by micropatterning in co-cultures: Hepatocytes and 3T3 fibroblasts
Bhatia, S. N., Yarmush, M. L., & Toner, M. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199702)34:2<189::aid-jbm8>3.0.co;2-m · Cited by 547
Ensembles of engineered cardiac tissues for physiological and pharmacological study: Heart on a chip
Grosberg, A., Alford, P. W., McCain, M. L., & Parker, K. K. (2011) · Lab on a Chip · doi:10.1039/c1lc20557a · Cited by 544
Role of gap junctions in the propagation of the cardiac action potential
Rohr, S. (2004) · Cardiovascular Research · doi:10.1016/j.cardiores.2003.11.035 · Cited by 465
Self-citationRotors and the Dynamics of Cardiac Fibrillation
Pandit, S. V., & Jalife, J. (2013) · Circulation Research · doi:10.1161/circresaha.111.300158 · Cited by 404
Nanotopography-guided tissue engineering and regenerative medicine
Kim, H. N., Jiao, A., Hwang, N. S., Kim, M. S., Kang, D. H., Kim, D.-H., & Suh, K.-Y. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.07.014 · Cited by 404
Electrotonic Modulation of Cardiac Impulse Conduction by Myofibroblasts
Miragoli, M., Gaudesius, G., & Rohr, S. (2006) · Circulation Research · doi:10.1161/01.res.0000214537.44195.a3 · Cited by 390
Self-citationBio-inspired intelligent structural color materials
Shang, L., Zhang, W., Xu, K., & Zhao, Y. (2019) · Materials Horizons · doi:10.1039/c9mh00101h · Cited by 301
Optical Imaging of Voltage and Calcium in Cardiac Cells & Tissues
Herron, T. J., Lee, P., & Jalife, J. (2012) · Circulation Research · doi:10.1161/circresaha.111.247494 · Cited by 289
Rohr, S., Kucera, J. P., & Kléber, A. G. (1998) · Circulation Research · doi:10.1161/01.res.83.8.781 · Cited by 271
Self-citationCellular Micropatterns on Biocompatible Materials
Folch, A., & Toner, M. (1998) · Biotechnology Progress · doi:10.1021/bp980037b · Cited by 270
Role of wavefront curvature in propagation of cardiac impulse
Fast, V. G., & Kléber, A. G. (1997) · Cardiovascular Research · doi:10.1016/s0008-6363(96)00216-7 · Cited by 269
Self-citationBursac, N., Parker, K. K., Iravanian, S., & Tung, L. (2002) · Circulation Research · doi:10.1161/01.res.0000047530.88338.eb · Cited by 268
Maleki, A., Ghomi, M., Nikfarjam, N., Akbari, M., Sharifi, E., Shahbazi, M., Kermanian, M., Seyedhamzeh, M., Nazarzadeh Zare, E., Mehrali, M., et al. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202203430 · Cited by 262
Controlling the contractile strength of engineered cardiac muscle by hierarchal tissue architecture
Feinberg, A. W., Alford, P. W., Jin, H., Ripplinger, C. M., Werdich, A. A., Sheehy, S. P., Grosberg, A., & Parker, K. K. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.04.043 · Cited by 240
“Previous work in modeling cardiac microenvironments experimentally by Kleber and colleagues demonstrated that patterned, in vitro cardiac myocyte cultures that constrain the cell monolayer in two dimensions (2D) can regulate sourceesink relationships, resulting in unique propagation of action potential wavefronts [9].”
Organ‐on‐chip models: Implications in drug discovery and clinical applications
Mittal, R., Woo, F. W., Castro, C. S., Cohen, M. A., Karanxha, J., Mittal, J., Chhibber, T., & Jhaveri, V. M. (2019) · Journal of Cellular Physiology · doi:10.1002/jcp.27729 · Cited by 234
Additive Manufacturing of Precision Biomaterials
Guzzi, E. A., & Tibbitt, M. W. (2020) · Advanced Materials · doi:10.1002/adma.201901994 · Cited by 234
Sarcomere alignment is regulated by myocyte shape
Bray, M., Sheehy, S. P., & Parker, K. K. (2008) · Cell Motility · doi:10.1002/cm.20290 · Cited by 228
“, 1992] Systematic alteration of the ECM microenvironment has been primarily concerned with tissue-level electrophysiology [Rohr et al., 1991; Bursac et al., 2004] and the response to mechanical stretch [Simpson et al.”
BackgroundA tissue-engineered scale model of the heart ventricle
MacQueen, L. A., Sheehy, S. P., Chantre, C. O., Zimmerman, J. F., Pasqualini, F. S., Liu, X., Goss, J. A., Campbell, P. H., Gonzalez, G. M., Park, S.-J., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0271-5 · Cited by 227
Biocompatible Carbon Nanotube–Chitosan Scaffold Matching the Electrical Conductivity of the Heart
Pok, S., Vitale, F., Eichmann, S. L., Benavides, O. M., Pasquali, M., & Jacot, J. G. (2014) · ACS Nano · doi:10.1021/nn503693h · Cited by 225
“Furthermore, SWNT incorporation also caused a decrease of actionpotential duration (APD) at both 50% (APD50) and 80% (APD80) of repolarization and had similar APD to native neonatal cardiomyocytes (∼120 ms of APD80).(63) Both APD50 and APD80 of engineered tissues containing SWNTs were significantly reduced compared to…”
BackgroundIn vitro generation of differentiated cardiac myofibers on micropatterned laminin surfaces
McDevitt, T. C., Angello, J. C., Whitney, M. L., Reinecke, H., Hauschka, S. D., Murry, C. E., & Stayton, P. S. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1292 · Cited by 197
Biology on a Chip: Microfabrication for Studying the Behavior of Cultured Cells
Li, N., Tourovskaia, A., & Folch, A. (2003) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v31.i56.20 · Cited by 186
Gopalan, S. M., Flaim, C., Bhatia, S. N., Hoshijima, M., Knoell, R., Chien, K. R., Omens, J. H., & McCulloch, A. D. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10506 · Cited by 183
“Rohr et al. (1991) grew neonatal rat ventricular myocytes on photoetched glass to control cell shape, alignment, and contact for studying action potential propagation.”
BackgroundDarrow, B. J., Fast, V. G., Kléber, A. G., Beyer, E. C., & Saffitz, J. E. (1996) · Circulation Research · doi:10.1161/01.res.79.2.174 · Cited by 169
Biohybrid thin films for measuring contractility in engineered cardiovascular muscle
Alford, P. W., Feinberg, A. W., Sheehy, S. P., & Parker, K. K. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.079 · Cited by 168
“Kleber and colleagues [1,2] first developed patterned cell cultures of ventricular myocytes to study the physics of excitation wave front propagation through custom designed microenvironments.”
Fast, V. G., & Kleber, A. G. (1995) · Cardiovascular Research · doi:10.1016/s0008-6363(96)88643-3 · Cited by 164
Rohr, S., & Salzberg, B. M. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80602-2 · Cited by 161
Self-citationA photolithographic method to create cellular micropatterns
Karp, J. M., Yeo, Y., Geng, W., Cannizarro, C., Yan, K., Kohane, D. S., Vunjak-Novakovic, G., Langer, R. S., & Radisic, M. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.04.028 · Cited by 134
“For physiological studies, elongated phenotype was achieved by patterning photoresist lanes on glass substrate and growing the myocytes on the exposed glass [2,3].”
BackgroundBiomechanics of Cardiac Electromechanical Coupling and Mechanoelectric Feedback
Pfeiffer, E. R., Tangney, J. R., Omens, J. H., & McCulloch, A. D. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4026221 · Cited by 131
“Working with neonatal cardiomyocytes, which are capable of forming mechanoelectric junctions in culture, geometrical cues presenting extracellular matrix protein have been found to guide cells into anisotropic and aligned morphology similar to that of developing myocardium [125–130].”
BackgroundMethodResult
Metadata
- Authors
- Rohr, S., Schölly, D. M., & Kléber, A. G.
- Venue
- Circulation Research
- Published
- 1991-01
- Volume
- 68
- Issue
- 1
- Pages
- 114-130
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2012933077
- Cited by
- 217
- References
- 0
- FWCI
- 1.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.