The DOI matches its Crossref record.
Characterization and localization of endothelin receptor subtypes in the human atrioventricular conducting system and myocardium.
Abstract
The characterization and localization of endothelin A (ETA) and endothelin B (ETB) receptors have been determined in tissue sections of the human atrioventricular conducting system, surrounding regions of atrial and ventricular myocardium, and the left ventricular free wall by use of radioligand binding, polymerase chain reaction, and in situ hybridization. Selective ETA (BQ123) and ETB (BQ3020) compounds in conjunction with [125I]endothelin-1 revealed the presence of ETA and ETB receptors in the left ventricular free wall (BQ123: 57 +/- 5% ETA, 43 +/- 2% ETB, n = 3; BQ3020: 67 +/- 3% ETA, 33 +/- 3% ETB, n = 3). Autoradiography using [125I]endothelin-1 in the absence or presence of BQ3020, BQ123, or endothelin-1 showed ETA and ETB receptors localized to atrial and ventricular myocardium, the atrioventricular conducting system, and endocardial cells. There was a higher proportion of ETB receptors in the atrioventricular node and the penetrating and branching bundles of His than in the surrounding interventricular and interatrial septa (p < 0.0001). There was a lower density of ETB receptors in the interventricular septum compared with the interatrial septum and the atrioventricular conducting system (p = 0.009) and a lower density of ETA receptors in the atrioventricular conducting system compared with interatrial and interventricular septa (p = 0.008). Isolated right atrial myocytes showed a higher proportion of ETA receptors (91 +/- 12%, n = 3). Amplification of left ventricular free wall cDNA by polymerase chain reaction revealed the presence of ETA and ETB receptor mRNA. mRNA for both subtypes was detected in isolated atrial myocytes. In situ hybridization showed ETA and ETB receptor mRNA localization to atrial and ventricular myocardium, the atrioventricular conducting system, and endocardial cells. These studies demonstrate the presence of ETA and ETB receptors in human myocardium and the atrioventricular conducting system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Davenport, A. P., Hyndman, K. A., Dhaun, N., Southan, C., Kohan, D. E., Pollock, J. S., Pollock, D. M., Webb, D. J., & Maguire, J. J. (2016) · Pharmacological Reviews · doi:10.1124/pr.115.011833 · Cited by 772
Self-citationBrutsaert, D. L. (2003) · Physiological Reviews · doi:10.1152/physrev.00017.2002 · Cited by 697
Inhibition of myocardial endothelin pathway improves long-term survival in heart failure
Sakai, S., Miyauchi, T., Kobayashi, M., Yamaguchi, I., Goto, K., & Sugishita, Y. (1996) · Nature · doi:10.1038/384353a0 · Cited by 622
Regulation of Blood Pressure and Salt Homeostasis by Endothelin
Kohan, D. E., Rossi, N. F., Inscho, E. W., & Pollock, D. M. (2011) · Physiological Reviews · doi:10.1152/physrev.00060.2009 · Cited by 433
Ruskoaho, H., Leskinen, H., Magga, J., Taskinen, P., Mäntymaa, P., Vuolteenaho, O., & Leppäluoto, J. (1997) · Journal of Molecular Medicine · doi:10.1007/s001090050179 · Cited by 324
Metadata
- Authors
- Molenaar, P., O'Reilly, G., Sharkey, A., Kuc, R. E., Harding, D. P., Plumpton, C., Gresham, G. A., & Davenport, A. P.
- Venue
- Circulation Research
- Published
- 1993-03
- Volume
- 72
- Issue
- 3
- Pages
- 526-538
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2073467418
- Cited by
- 255
- References
- 0
- FWCI
- 11.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization and localization of endothelin receptor subtypes in the human atrioventricular conducting system and myocardium. https://app.cochat.ai/papers/10.1161/01.res.72.3.526
- The paper
- Molenaar, P., O'Reilly, G., Sharkey, A., Kuc, R. E., Harding, D. P., Plumpton, C., Gresham, G. A., & Davenport, A. P. (1993). Characterization and localization of endothelin receptor subtypes in the human atrioventricular conducting system and myocardium. Circulation Research. https://doi.org/10.1161/01.res.72.3.526
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.