Anisotropy of water diffusion in the myocardium of the rat.
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Pulsed field gradient nuclear magnetic resonance methods combined with nuclear magnetic resonance imaging were used to determine the water diffusion anisotropy in perfused rat hearts at 37 degrees C. It was found that the observed diffusion coefficient D(app) (apparent diffusion coefficient) depends on the orientation of the applied gradient g. When g is parallel to the epicardial surface, the observed diffusivity is D(app) parallel = 1.8 +/- 0.4 x 10(-9) m2.s-1, whereas when g is perpendicular to it, diffusivity is D(app) perpendicular = 2.5 +/- 0.5 x 10(-9) m2.s-1. To better characterize this directional dependence, images of the second-order diffusion tensor D of the myocardium were obtained. These data demonstrate several essential features of cardiac myoarchitecture, including the helicity of fiber orientation with respect to the ventricular axis and the variation of fiber pitch angle with transmural depth. Diffusion anisotropy may be quantified in a coordinate-independent manner by the eigenvalues of the diffusion tensor. In the myocardial midwall, these eigenvalues were E1 = 3.29 +/- 0.57, E2 = 2.01 +/- 0.42, and E3 = 0.77 +/- 0.58 x 10(-9) m2.s-1 (mean +/- SD). These data suggest that myocardial water diffusion is essentially unrestricted parallel to the myofibers. They further show that failure to measure the complete diffusion tensor may lead to substantial underestimates of diffusion anisotropy in the myocardium.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Cited by
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
Toward a quantitative assessment of diffusion anisotropy
Pierpaoli, C., & Basser, P. J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360612 · Cited by 2,405
High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity
Tuch, D. S., Reese, T. G., Wiegell, M. R., Makris, N., Belliveau, J. W., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10268 · Cited by 1,548
Self-citationBasser, P. J. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080707 · Cited by 1,519
Diffusion‐tensor MRI: theory, experimental design and data analysis – a technical review
Basser, P. J., & Jones, D. K. (2002) · NMR in Biomedicine · doi:10.1002/nbm.783 · Cited by 1,478
Metadata
- Authors
- Garrido, L., Wedeen, V. J., Kwong, K. K., Spencer, U. M., & Kantor, H. L.
- Venue
- Circulation Research
- Published
- 1994-05
- Volume
- 74
- Issue
- 5
- Pages
- 789-793
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2163277230
- Cited by
- 137
- References
- 1
- FWCI
- 5.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Anisotropy of water diffusion in the myocardium of the rat. https://app.cochat.ai/papers/10.1161/01.res.74.5.789
- The paper
- Garrido, L., Wedeen, V. J., Kwong, K. K., Spencer, U. M., & Kantor, H. L. (1994). Anisotropy of water diffusion in the myocardium of the rat. Circulation Research. https://doi.org/10.1161/01.res.74.5.789
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.