Anisotropy of water diffusion in the myocardium of the rat.
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Pulsed field gradient nuclear magnetic resonance methods combined with nuclear magnetic resonance imaging were used to determine the water diffusion anisotropy in perfused rat hearts at 37 degrees C. It was found that the observed diffusion coefficient D(app) (apparent diffusion coefficient) depends on the orientation of the applied gradient g. When g is parallel to the epicardial surface, the observed diffusivity is D(app) parallel = 1.8 +/- 0.4 x 10(-9) m2.s-1, whereas when g is perpendicular to it, diffusivity is D(app) perpendicular = 2.5 +/- 0.5 x 10(-9) m2.s-1. To better characterize this directional dependence, images of the second-order diffusion tensor D of the myocardium were obtained. These data demonstrate several essential features of cardiac myoarchitecture, including the helicity of fiber orientation with respect to the ventricular axis and the variation of fiber pitch angle with transmural depth. Diffusion anisotropy may be quantified in a coordinate-independent manner by the eigenvalues of the diffusion tensor. In the myocardial midwall, these eigenvalues were E1 = 3.29 +/- 0.57, E2 = 2.01 +/- 0.42, and E3 = 0.77 +/- 0.58 x 10(-9) m2.s-1 (mean +/- SD). These data suggest that myocardial water diffusion is essentially unrestricted parallel to the myofibers. They further show that failure to measure the complete diffusion tensor may lead to substantial underestimates of diffusion anisotropy in the myocardium.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Cited by
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
Toward a quantitative assessment of diffusion anisotropy
Pierpaoli, C., & Basser, P. J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360612 · Cited by 2,405
High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity
Tuch, D. S., Reese, T. G., Wiegell, M. R., Makris, N., Belliveau, J. W., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10268 · Cited by 1,548
Self-citationBasser, P. J. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080707 · Cited by 1,519
Diffusion‐tensor MRI: theory, experimental design and data analysis – a technical review
Basser, P. J., & Jones, D. K. (2002) · NMR in Biomedicine · doi:10.1002/nbm.783 · Cited by 1,478
Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo
Reese, T. G., Heid, O., Weisskoff, R. M., & Wedeen, V. J. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10308 · Cited by 1,227
Self-citationPajevic, S., & Pierpaoli, C. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200006)43:6<921::aid-mrm23>3.0.co;2-i · Cited by 763
Pajevic, S., & Pierpaoli, C. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<526::aid-mrm15>3.0.co;2-j · Cited by 640
A simplified method to measure the diffusion tensor from seven MR images
Basser, P. J., & Pierpaoli, C. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390610 · Cited by 583
Scollan, D. F., Holmes, A., Winslow, R., & Forder, J. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.275.6.h2308 · Cited by 457
Magnetic resonance myocardial fiber-orientation mapping with direct histological correlation
Hsu, E. W., Muzikant, A. L., Matulevicius, S. A., Penland, R. C., & Henriquez, C. S. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.5.h1627 · Cited by 386
Makris, N., Worth, A. J., Papadimitriou, G. M., Stakes, J. W., Caviness, V. S., Kennedy, D. N., Pandya, D. N., Kaplan, E., Sorensen, A. G., Wu, O., et al. (1997) · Annals of Neurology · doi:10.1002/ana.410420617 · Cited by 380
Self-citationCharacterization of and correction for eddy current artifacts in echo planar diffusion imaging
Jezzard, P., Barnett, A. S., & Pierpaoli, C. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390518 · Cited by 352
Statistical artifacts in diffusion tensor MRI (DT-MRI) caused by background noise
Basser, P. J., & Pajevic, S. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200007)44:1<41::aid-mrm8>3.0.co;2-o · Cited by 318
Conturo, T. E., McKinstry, R. C., Akbudak, E., & Robinson, B. H. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350319 · Cited by 300
Imaging myocardial fiber architecture in vivo with magnetic resonance
Reese, T. G., Weisskoff, R. M., Smith, R. N., Rosen, B. R., Dinsmore, R. E., & Wedeen, V. J. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340603 · Cited by 292
Self-citationWu, M.-T., Tseng, W.-Y. I., Su, M.-Y. M., Liu, C.-P., Chiou, K.-R., Wedeen, V. J., Reese, T. G., & Yang, C.-F. (2006) · Circulation · doi:10.1161/circulationaha.105.545863 · Cited by 291
Self-citationNielles-Vallespin, S., Khalique, Z., Ferreira, P. F., de Silva, R., Scott, A. D., Kilner, P., McGill, L.-A., Giannakidis, A., Gatehouse, P. D., Ennis, D., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.11.051 · Cited by 267
Automatic segmentation of thalamic nuclei from diffusion tensor magnetic resonance imaging
Wiegell, M. R., Tuch, D. S., Larsson, H. B. W., & Wedeen, V. J. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00044-2 · Cited by 258
Self-citationEx vivo 3D diffusion tensor imaging and quantification of cardiac laminar structure
Helm, P. A., Tseng, H., Younes, L., McVeigh, E. R., & Winslow, R. L. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20622 · Cited by 227
“tertiary eigenvalues) also introduces a bias in the mean and variance of the sample eigenvectors (principle directions), and degrades the characterization of tissue anisotropy (14,15).”
BackgroundThe Biological Basis of Diffusion Anisotropy
Beaulieu, C. (2009) · Diffusion MRI · doi:10.1016/b978-0-12-374709-9.00006-7 · Cited by 217
Norris, D. G. (2001) · NMR in Biomedicine · doi:10.1002/nbm.682 · Cited by 213
“The primary application for this methodology is in the early detection of cerebral ischemia, although the advent of diffusion tensor imaging (DTI) has also made it possible to image the fiber tracts in white matter of the brain and potentially in other organs such as the heart.(21) Furthermore, diffusion-weighted imag…”
BackgroundGeerts, L., Bovendeerd, P., Nicolay, K., & Arts, T. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00968.2001 · Cited by 200
“In our experiments, Jones’ condition was met with b values, as defined by others (8), of 0 and 1,763 s/mm2.”
MethodNielles‐Vallespin, S., Mekkaoui, C., Gatehouse, P., Reese, T. G., Keegan, J., Ferreira, P. F., Collins, S., Speier, P., Feiweier, T., de Silva, R., et al. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24488 · Cited by 181
Costa, K. D., Hunter, P. J., Wayne, J. S., Waldman, L. K., Guccione, J. M., & McCulloch, A. D. (1996) · Journal of Biomechanical Engineering · doi:10.1115/1.2796032 · Cited by 172
Diffusion MR tractography of the heart
Sosnovik, D. E., Wang, R., Dai, G., Reese, T. G., & Wedeen, V. J. (2009) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-11-47 · Cited by 168
Self-citationDiffusion tensor imaging in biomechanical studies of skeletal muscle function
VAN DONKELAAR, C. C., KRETZERS, L. J. G., BOVENDEERD, P. H. M., LATASTER, L. M. A., NICOLAY, K., JANSSEN, J. D., & DROST, M. R. (1999) · Journal of Anatomy · doi:10.1046/j.1469-7580.1999.19410079.x · Cited by 141
The Biological Basis of Diffusion Anisotropy
Beaulieu, C. (2014) · Diffusion MRI · doi:10.1016/b978-0-12-396460-1.00008-1 · Cited by 66
Small animal cardiovascular MR imaging and spectroscopy
Bakermans, A. J., Abdurrachim, D., Moonen, R. P. M., Motaal, A. G., Prompers, J. J., Strijkers, G. J., Vandoorne, K., & Nicolay, K. (2015) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2015.03.001 · Cited by 35
Metadata
- Authors
- Garrido, L., Wedeen, V. J., Kwong, K. K., Spencer, U. M., & Kantor, H. L.
- Venue
- Circulation Research
- Published
- 1994-05
- Volume
- 74
- Issue
- 5
- Pages
- 789-793
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2163277230
- Cited by
- 137
- References
- 1
- FWCI
- 5.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.