Wall shear stress temporal gradient and anastomotic intimal hyperplasia.
The DOI matches its Crossref record.
Abstract
Unusual wall shear stress patterns on the bed of end-to-side arterial anastomoses appear to be the primary factor in the development of intimal hyperplasia that often leads to arterial bypass graft failure. In this in vitro study using the photochromic tracer technique, the shear stress variation on the bed of a 30 degrees anastomosis was examined before and after the development of hyperplasia. With the disease-free model, a rapid downstream shift in the stagnation point was seen on the bed during the systolic phase of the flow cycle, which led to sharp temporal changes in the shear stress from positive to negative values, ie, rapid changes in the direction of the shearing force. The resulting negative temporal gradients were roughly eight times larger than those seen in a straight tube, and it is suggested that this may lead to endothelial deformation or injury and eventually to intimal thickening. With the diseased model, the simulated tissue overgrowth on the bed appeared to act as a flow divider that restricted the motion of the stagnation point, and this drastically reduced the rapid changes in the direction of the shearing forces. Thus, it seems that the development of bed anastomotic intimal hyperplasia may be a response designed to reduce shear-induced endothelial deformation or injury.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chiu, J.-J., & Chien, S. (2011) · Physiological Reviews · doi:10.1152/physrev.00047.2009 · Cited by 2,280
“Using the photochromic tracer technique to visualize the variations of shear stress in a 30° anastomosis in the absence (disease-free model) or presence of intimal hyperplasia (disease model produced by fitting the wall of the native artery with an elliptical plug to simulate the presence of intimal hyperplasia on the…”
MethodThe Mechanical Behavior of Vascular Grafts: A Review
Salacinski, H. J., Goldner, S., Giudiceandrea, A., Hamilton, G., Seifalian, A. M., Edwards, A., & Carson, R. J. (2001) · Journal of Biomaterials Applications · doi:10.1106/na5t-j57a-jtdd-fd04 · Cited by 399
Compliance mismatch may promote graft–artery intimal hyperplasia by altering suture-line stresses
Ballyk, P. D., Walsh, C., Butany, J., & Ojha, M. (1997) · Journal of Biomechanics · doi:10.1016/s0197-3975(97)00111-5 · Cited by 272
Self-citationPuskas, J. E., & Chen, Y. (2004) · Biomacromolecules · doi:10.1021/bm034513k · Cited by 269
Patient-Specific Multiscale Modeling of Blood Flow for Coronary Artery Bypass Graft Surgery
Sankaran, S., Esmaily Moghadam, M., Kahn, A. M., Tseng, E. E., Guccione, J. M., & Marsden, A. L. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0579-3 · Cited by 237
Bao, X., Lu, C., & Frangos, J. A. (1999) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.19.4.996 · Cited by 220
Ene-Iordache, B., & Remuzzi, A. (2012) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfr342 · Cited by 188
“Beside OSI and RRT, which incorporates both OSI and TAWSS, other parameters that were previously proposed to quantify the haemodynamic disturbances as predictors of arterial wall sites at risk, like the WSS spatial gradient [42], the WSS temporal gradient [43] or the WSS angle gradient [44] are worth investigating in…”
BackgroundTemporal Gradients in Shear, but Not Spatial Gradients, Stimulate Endothelial Cell Proliferation
White, C. R., Haidekker, M., Bao, X., & Frangos, J. A. (2001) · Circulation · doi:10.1161/01.cir.103.20.2508 · Cited by 178
“5 seconds, followed by a 15-second ramped decrease and 20 minutes of no flow); (3) step flow (a sudden shear stress increase from 0 to 10 dyne/cm(2), and then steady shear sustained for 20 minutes); (4) ramped flow (a smooth 15-second ramped increase from 0 to 10 dyne/cm(2), and then steady shear sustained for 20 minu…”
Background
Metadata
- Authors
- Ojha, M.
- Venue
- Circulation Research
- Published
- 1994-06
- Volume
- 74
- Issue
- 6
- Pages
- 1227-1231
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W1969706956
- Cited by
- 169
- References
- 0
- FWCI
- 6.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.