CoChat

The Mechanically Active Domain of Titin in Cardiac Muscle

Trombitás, Károly, Jin, Jian-Ping, Granzier, Henk · 1995 · Circulation Research
Cited by 133

The DOI matches its Crossref record.

Abstract

Abstract One of the main contributors to passive tension of the myocardium is titin. However, it is not exactly known what portions of this ≈1 μm-long molecule are anchored in the sarcomere (hence, are rendered inelastic) and what portions are elastic (hence, are mechanically active in developing passive tension). We assessed the length of the elastic domain of cardiac titin by ultrastructural and mechanical methods. Single cardiac myocytes were stretched by various amounts, and while in the stretched state, they were processed for immunoelectron microscopy. Several monoclonal anti-titin antibodies were used, and the locations of the titin epitopes in the sarcomere were studied as a function of sarcomere length. Only a small fraction (5% to 10%) of the ≈1000-nm-long molecule behaved elastically under physiological conditions. This mechanically active domain is located close to the A/I junction, and its contour length when unstretched is estimated at ≈50 to 100 nm. In sarcomeres that are slack (length ≈1.85 μm), the mechanically active domain is folded on top of itself, and the length of the domain reaches an elastic limit of ≈550 nm in sarcomeres that are ≈2.9 μm long.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.77.4.856

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Trombitás, K., Jin, J.-P., & Granzier, H.
Venue
Circulation Research
Published
1995-10
Volume
77
Issue
4
Pages
856-861
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2089940478
Cited by
133
References
0
FWCI
7.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.