Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 225

The DOI matches its Crossref record.

Spatiotemporal Heterogeneity in the Induction of Ventricular Fibrillation by Rapid Pacing: Importance of Cardiac Restitution Properties

Open access
Cao, Ji-Min, Qu, Zhilin, Kim, Young-Hoon, Wu, Tsu-Juey, Garfinkel, Alan, Weiss, James N., Karagueuzian, Hrayr S., Chen, Peng-Sheng · 1999 · Circulation Research

Abstract

Abstract —The mechanism by which rapid pacing induces ventricular fibrillation (VF) is unclear. We performed computerized epicardial mapping studies in 10 dogs, using 19-beat pacing trains. The pacing interval (PI) of the first train was 300 ms and then was progressively shortened until VF was induced. For each PI, we constructed restitution curves for the effective refractory period (ERP). When the PI was long, the activation cycle length (CL) was constant throughout the mapped region. However, as the PI shortened, there was an increase in the spatiotemporal complexity of the CL variations and an increase in the slope of the ERP restitution curve. In 5 dogs, we documented the initiation of VF by wavebreak at the site of long-short CL variations. Computer simulation studies using the Luo-Rudy I ventricular action potential model in simulated 2-dimensional tissue reproduced the experimental results when normal ERP and conduction velocity (CV) restitution properties were intact. By altering CV and ERP restitutions in this model, we found that CV restitution creates spatial CL variations, whereas ERP restitution underlies temporal, beat-to-beat variations in refractoriness during rapid pacing. Together, the interaction of CV and ERP restitutions produces spatiotemporal oscillations in cardiac activation that increase in amplitude as the PI decreases, ultimately causing wavebreak at the site of intrinsic heterogeneity. This initial wavebreak then leads to the formation of spiral waves and VF. These findings support a key role for both CV and ERP restitutions in the initiation of VF by rapid pacing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.84.11.1318

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 225

Metadata

Authors
Cao, J.-M., Qu, Z., Kim, Y.-H., Wu, T.-J., Garfinkel, A., Weiss, J. N., Karagueuzian, H. S., & Chen, P.-S.
Venue
Circulation Research
Published
1999-06-11
Volume
84
Issue
11
Pages
1318-1331
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2156291625
Cited by
225
References
0
FWCI
5.88
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Spatiotemporal Heterogeneity in the Induction of Ventricular Fibrillation by Rapid Pacing: Importance of Cardiac Restitution Properties. https://app.cochat.ai/papers/10.1161/01.res.84.11.1318
The paper
Cao, J.-M., Qu, Z., Kim, Y.-H., Wu, T.-J., Garfinkel, A., Weiss, J. N., Karagueuzian, H. S., & Chen, P.-S. (1999). Spatiotemporal Heterogeneity in the Induction of Ventricular Fibrillation by Rapid Pacing: Importance of Cardiac Restitution Properties. Circulation Research. https://doi.org/10.1161/01.res.84.11.1318

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.