The DOI matches its Crossref record.
Transient and Steady-State Effects of Shear Stress on Endothelial Cell Adherens Junctions
Open accessAbstract
Abstract —Endothelial cells exhibit profound changes in cell shape in response to altered shear stress that may require disassembly/reassembly of adherens junction protein complexes that mediate cell-cell adhesion. To test this hypothesis, we exposed confluent porcine aortic endothelial cells to 15 dyne/cm 2 of shear stress for 0, 8.5, 24, or 48 hours, using a parallel plate flow chamber. Cells were fixed and stained with antibodies to vascular endothelial (VE) cadherin, α-catenin, β-catenin, or plakoglobin. Under static conditions, staining for all proteins was intense and peripheral, forming a nearly continuous band around the cells at cell-cell junctions. After 8.5 hours of shear stress, staining was punctate and occurred only at sites of continuous cell attachment. After 24 or 48 hours of shear, staining for VE-cadherin, α-catenin, and β-catenin was intense and peripheral, forming a band of “dashes” (adherens plaques) that colocalized with the ends of stress fibers that inserted along the lateral membranes of cells. Staining for plakoglobin was not observed after 24 hours of shear stress, but returned after 48 hours. Western blot analysis indicated that protein levels of VE-cadherin, α-catenin, and plakoglobin decreased, whereas β-catenin levels increased after 8.5 hours of shear stress. As cell shape change reached completion (24 to 48 hours), all protein levels were upregulated except for plakoglobin, which remained below control levels. The partial disassembly of adherens junctions we have observed during shear induced changes in endothelial cell shape may have important implications for control of the endothelial permeability barrier and other aspects of endothelial cell function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The role of shear stress in the pathogenesis of atherosclerosis
Cunningham, K. S., & Gotlieb, A. I. (2005) · Laboratory Investigation · doi:10.1038/labinvest.3700215 · Cited by 1,151
Self-citationFluid shear stress and the vascular endothelium: for better and for worse
Resnick, N., Yahav, H., Shay-Salit, A., Shushy, M., Schubert, S., Zilberman, L. C. M., & Wofovitz, E. (2003) · Progress in Biophysics and Molecular Biology · doi:10.1016/s0079-6107(02)00052-4 · Cited by 577
Komarova, Y. A., Kruse, K., Mehta, D., & Malik, A. B. (2017) · Circulation Research · doi:10.1161/circresaha.116.306534 · Cited by 503
Primary cilia mediate mechanosensing in bone cells by a calcium-independent mechanism
Malone, A. M. D., Anderson, C. T., Tummala, P., Kwon, R. Y., Johnston, T. R., Stearns, T., & Jacobs, C. R. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0700636104 · Cited by 477
VEGF receptor 2 and the adherens junction as a mechanical transducer in vascular endothelial cells
Shay-Salit, A., Shushy, M., Wolfovitz, E., Yahav, H., Breviario, F., Dejana, E., & Resnick, N. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.142224299 · Cited by 339
Metadata
- Authors
- Noria, S., Cowan, D. B., Gotlieb, A. I., & Langille, B. L.
- Venue
- Circulation Research
- Published
- 1999-09-17
- Volume
- 85
- Issue
- 6
- Pages
- 504-514
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2137186141
- Cited by
- 252
- References
- 0
- FWCI
- 3.45
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transient and Steady-State Effects of Shear Stress on Endothelial Cell Adherens Junctions. https://app.cochat.ai/papers/10.1161/01.res.85.6.504
- The paper
- Noria, S., Cowan, D. B., Gotlieb, A. I., & Langille, B. L. (1999). Transient and Steady-State Effects of Shear Stress on Endothelial Cell Adherens Junctions. Circulation Research. https://doi.org/10.1161/01.res.85.6.504
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.