Synthetic Strands of Neonatal Mouse Cardiac Myocytes: Structural and Electrophysiological Properties
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Abstract —The aim of the present study was to morphologically and electrically characterize synthetic strands of mouse ventricular myocytes. Linear strands of mouse ventricular myocytes with widths of 34.7±4.4 μm (W 1 ), 57.9±2.5 μm (W 2 ), and 86.4±3.6 μm (W 3 ) and a length of 10 mm were produced on glass coverslips with a photolithographic technique. Action potentials (APs) were measured from individual cells within the strands with cell-attached microelectrodes. Impulse propagation and AP upstrokes were measured with multisite optical mapping (RH237). Immunostaining was performed to assess cell-cell connections and myofibril arrangement with polyclonal antisera against connexin43 and N-cadherins and monoclonal antibodies against cardiac myosin. Light microscopy and myosin staining showed dense growth of well-developed elongated myocytes with lengths of 34.2±4.2 μm (W 1 ), 36.9±5.8 μm (W 2 ), and 43.7±6.9 μm (W 3 ), and length/width ratios of 3.9±0.2. Gap junctions were distributed around the cell borders (3 to 4 junctions/μm 2 cell area). Each cell was connected by gap junctions to 6.5±1.1 neighboring cells. AP duration shortened with time in culture (action potential duration at 50% repolarization: day 4, 103±34 ms; day 8, 16±3 ms; P <0.01). Minimum diastolic potential and AP amplitude were 71±5 and 97.2±7.6 mV, respectively. Conduction velocity and the maximum dV/dt of the AP upstroke were 43.9±13.6 cm/s and 196±67 V/s, respectively. Thus, neonatal ventricular mouse myocytes can be grown in continuous synthetic strands. Gap junction distribution is similar to the neonatal pattern observed in the hearts of larger mammals. Conduction velocity is in the range observed in adult mice and in the higher range for mammalian species probably due to the higher dV/dt max . This technique will permit the study of propagation, AP, and structure-function relations at cellular resolution in genetically modified mice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
[6] Correction for liquid junction potentials in patch clamp experiments
Neher, E. (1992) · Methods in Enzymology · doi:10.1016/0076-6879(92)07008-c · Cited by 1,132
Rohr, S., Kucera, J. P., & Kléber, A. G. (1998) · Circulation Research · doi:10.1161/01.res.83.8.781 · Cited by 271
Cited by
Basic Mechanisms of Cardiac Impulse Propagation and Associated Arrhythmias
KLÉBER, A. G., & RUDY, Y. (2004) · Physiological Reviews · doi:10.1152/physrev.00025.2003 · Cited by 1,083
Self-citationEnsembles of engineered cardiac tissues for physiological and pharmacological study: Heart on a chip
Grosberg, A., Alford, P. W., McCain, M. L., & Parker, K. K. (2011) · Lab on a Chip · doi:10.1039/c1lc20557a · Cited by 544
Nanotopography-guided tissue engineering and regenerative medicine
Kim, H. N., Jiao, A., Hwang, N. S., Kim, M. S., Kang, D. H., Kim, D.-H., & Suh, K.-Y. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.07.014 · Cited by 404
Kehat, I., Gepstein, A., Spira, A., Itskovitz-Eldor, J., & Gepstein, L. (2002) · Circulation Research · doi:10.1161/01.res.0000039084.30342.9b · Cited by 298
Tissue Engineering Approaches in the Design of Healthy and Pathological In Vitro Tissue Models
Caddeo, S., Boffito, M., & Sartori, S. (2017) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2017.00040 · Cited by 285
“For instance, aligned murine CMs showed calcium handling, action potentials and conductivity more similar to adult mouse heart, with respect to the same cells cultivated on randomly oriented substrates (Thomas et al., 2000; Pong et al., 2011).”
BackgroundAsimaki, A., Kapoor, S., Plovie, E., Karin Arndt, A., Adams, E., Liu, Z., James, C. A., Judge, D. P., Calkins, H., Churko, J., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008008 · Cited by 274
Self-citationEschenhagen, T., & Zimmermann, W. H. (2005) · Circulation Research · doi:10.1161/01.res.0000196562.73231.7d · Cited by 261
Controlling the contractile strength of engineered cardiac muscle by hierarchal tissue architecture
Feinberg, A. W., Alford, P. W., Jin, H., Ripplinger, C. M., Werdich, A. A., Sheehy, S. P., Grosberg, A., & Parker, K. K. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.04.043 · Cited by 240
“of a custom-built optical mapping system integrated into an inverted epifluorescence microscope (Axiovert 200, Carl Zeiss Microimaging, Thornwood, NY, USA), similar to previously published methods [19].”
Microfluidic patterning for fabrication of contractile cardiac organoids
Khademhosseini, A., Eng, G., Yeh, J., Kucharczyk, P. A., Langer, R., Vunjak-Novakovic, G., & Radisic, M. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9013-7 · Cited by 202
“Elongated phenotype was achieved by patterning photoresist lanes on glass substrate and growing the myocytes onto the exposed glass (Rohr et al., 1991; Thomas et al., 2000).”
MethodIn vitro generation of differentiated cardiac myofibers on micropatterned laminin surfaces
McDevitt, T. C., Angello, J. C., Whitney, M. L., Reinecke, H., Hauschka, S. D., Murry, C. E., & Stayton, P. S. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1292 · Cited by 197
“A recent study by Thomas et al.(15) reported on the electrophysiological properties of neonatal mouse cardiomyocytes grown in strands 35–86 m in diameter, guided by photolithographic patterning of coverslips that directed subsequent serum protein adsorption.”
In vitro cardiac tissue models: Current status and future prospects
Mathur, A., Ma, Z., Loskill, P., Jeeawoody, S., & Healy, K. E. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.09.011 · Cited by 187
“Significant observations in calcium handling, action potentials, and conductional velocities were more similar to adult mouse myocardium in aligned CMs as compared to those grown in randomly oriented cultures [60, 61].”
ResultBiology on a Chip: Microfabrication for Studying the Behavior of Cultured Cells
Li, N., Tourovskaia, A., & Folch, A. (2003) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v31.i56.20 · Cited by 186
A photolithographic method to create cellular micropatterns
Karp, J. M., Yeo, Y., Geng, W., Cannizarro, C., Yan, K., Kohane, D. S., Vunjak-Novakovic, G., Langer, R. S., & Radisic, M. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.04.028 · Cited by 134
“For physiological studies, elongated phenotype was achieved by patterning photoresist lanes on glass substrate and growing the myocytes on the exposed glass [2,3].”
Background
Metadata
- Authors
- Thomas, S. P., Bircher-Lehmann, L., Thomas, S. A., Zhuang, J., Saffitz, J. E., & Kléber, A. G.
- Venue
- Circulation Research
- Published
- 2000-09-15
- Volume
- 87
- Issue
- 6
- Pages
- 467-473
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2165677217
- Cited by
- 84
- References
- 2
- FWCI
- 1.88
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.