The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Duplex Ultrasound and Magnetic Resonance Angiography Compared With Digital Subtraction Angiography in Carotid Artery Stenosis: A Systematic Review
Open accessAbstract
Background and Purpose— The purpose of this work was to review and compare published data on the diagnostic value of duplex ultrasonography (DUS), MR angiography (MRA), and conventional digital subtraction angiography (DSA) for the diagnosis of carotid artery stenosis. Methods— We performed a systematic review of published studies retrieved through PUBMED, from bibliographies of review papers, and from experts. The English-language medical literature was searched for studies that met the selection criteria: (1) The study was published between 1994 and 2001; (2) MRA and/or DUS was performed to estimate the severity of carotid artery stenosis; (3) DSA was used as the standard of reference; and (4) the absolute numbers of true positives, false negatives, true negatives, and false positives were available or derivable for at least one definition of disease (degree of stenosis). Results— Sixty-three publications on duplex, MRA, or both were included in the analysis, yielding the test results of 64 different patient series on DUS and 21 on MRA. For the diagnosis of 70% to 99% versus <70% stenosis, MRA had a pooled sensitivity of 95% (95% CI, 92 to 97) and a pooled specificity of 90% (95% CI, 86 to 93). These numbers were 86% (95% CI, 84 to 89) and 87% (95% CI, 84 to 90) for DUS, respectively. For recognizing occlusion, MRA yielded a sensitivity of 98% (95% CI, 94 to 100) and a specificity of 100% (95% CI, 99 to 100), and DUS had a sensitivity of 96% (95% CI, 94 to 98) and a specificity of 100% (95% CI, 99 to 100). A multivariable summary receiver-operating characteristic curve (ROC) analysis for diagnosing 70% to 99% stenosis demonstrated that the type of MR scanner predicted the performance of MRA, whereas the presence of verification bias predicted the performance of DUS. For diagnosing occlusion, no significant heterogeneity was found for MRA; for DUS, the presence of verification bias and type of DUS scanner were explanatory variables. MRA had a significantly better discriminatory power than DUS in diagnosing 70% to 99% stenosis (regression coefficient, 1.6; 95% CI, 0.37 to 2.77). No significant difference was found in detecting occlusion (regression coefficient, 0.73; 95% CI, −2.06 to 3.51). Conclusions— These results suggest that MRA has a better discriminatory power compared with DUS in diagnosing 70% to 99% stenosis and is a sensitive and specific test compared with DSA in the evaluation of carotid artery stenosis. For detecting occlusion, both DUS and MRA are very accurate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moher, D., Cook, D. J., Eastwood, S., Olkin, I., Rennie, D., & Stroup, D. F. (1999) · The Lancet · doi:10.1016/s0140-6736(99)04149-5 · Cited by 4,826
Benefit of Carotid Endarterectomy in Patients with Symptomatic Moderate or Severe Stenosis
Barnett, H. J. M., Taylor, D. W., Eliasziw, M., Fox, A. J., Ferguson, G. G., Haynes, R. B., Rankin, R. N., Clagett, G. P., Hachinski, V. C., Sackett, D. L., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199811123392002 · Cited by 3,594
Guidelines for Meta-analyses Evaluating Diagnostic Tests
Irwig, L., Tosteson, A. N. A., Gatsonis, C., Lau, J., Colditz, G., Chalmers, T. C., & Mosteller, F. (1994) · Annals of Internal Medicine · doi:10.7326/0003-4819-120-8-199404150-00008 · Cited by 753
Assessment of diagnostic tests when disease verification is subject to selection bias
Begg, C. B., & Greenes, R. A. (1983) · Biometrics · doi:10.2307/2530820 · Cited by 708
Bendszus, M., Koltzenburg, M., Burger, R., Warmuth-Metz, M., Hofmann, E., & Solymosi, L. (1999) · The Lancet · doi:10.1016/s0140-6736(99)07083-x · Cited by 528
Estimating Diagnostic Accuracy from Multiple Conflicting Reports: A New Meta-analytic Method
Littenberg, B., & Moses, L. E. (1993) · Medical Decision Making · doi:10.1177/0272989x9301300408 · Cited by 434
Randoux, B., Marro, B., Koskas, F., Duyme, M., Sahel, M., Zouaoui, A., & Marsault, C. (2001) · Radiology · doi:10.1148/radiology.220.1.r01jl35179 · Cited by 300
Moneta, G. L., Edwards, J. M., Papanicolaou, G., Hatsukami, T., Taylor, L. M., Strandness, D. E., & Porter, J. M. (1995) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(95)70228-8 · Cited by 218
Noninvasive Carotid Artery Testing: A Meta-analytic Review
Blakeley, D. D., Oddone, E. Z., Hasselblad, V., Simel, D. L., & Matchar, D. B. (1995) · Annals of Internal Medicine · doi:10.7326/0003-4819-122-5-199503010-00007 · Cited by 215
Eliasziw, M., Rankin, R. N., Fox, A. J., Haynes, R. B., & Barnett, H. J. M. (1995) · Stroke · doi:10.1161/01.str.26.10.1747 · Cited by 202
Hankey, G. J., Warlow, C. P., & Molyneux, A. J. (1990) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.53.7.542 · Cited by 184
Prospective evaluation of new duplex criteria to identify 70% internal carotid artery stenosis
Hood, D. B., Mattos, M. A., Mansour, A., Ramsey, D. E., Hodgson, K. J., Barkmeier, L. D., & Sumner, D. S. (1996) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(96)70269-0 · Cited by 164
Kent, K. C. (1995) · JAMA · doi:10.1001/jama.1995.03530110050035 · Cited by 161
Pan, X. M., Saloner, D., Reilly, L. M., Bowersox, J. C., Murray, S. P., Anderson, C. M., Gooding, G. A. W., & Rapp, J. H. (1995) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(95)70246-6 · Cited by 140
Mittl, R. L., Broderick, M., Carpenter, J. P., Goldberg, H. I., Listerud, J., Mishkin, M. M., Berkowitz, H. D., & Atlas, S. W. (1994) · Stroke · doi:10.1161/01.str.25.1.4 · Cited by 126
AbuRahma, A. F., Robinson, P. A., Strickler, D. L., Alberts, S., & Young, L. (1998) · Annals of Vascular Surgery · doi:10.1007/s100169900166 · Cited by 114
Serfaty, J., Chirossel, P., Chevallier, J. M., Écochard, R., Froment, J. C., & Douek, P. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.175.2.1750455 · Cited by 113
de Vries, S. O., Hunink, M. G. M., & Polak, J. F. (1996) · Academic Radiology · doi:10.1016/s1076-6332(96)80257-1 · Cited by 107
Self-citationDiagnosis of internal carotid artery stenosis greater than 70% with power Doppler duplex sonography.
Koga, M., Kimura, K., Minematsu, K., & Yamaguchi, T. (2001) · PubMed Central · Cited by 105
Rothwell, P. M., Pendlebury, S. T., Wardlaw, J. M., & Warlow, C. P. (2000) · Stroke · doi:10.1161/01.str.31.6.1444 · Cited by 104
Redefined Duplex Ultrasonographic Criteria for Diagnosis of Carotid Artery Stenosis
Huston, J., James, E. M., Brown, R. D., Lefsrud, R. D., Ilstrup, D. M., Robertson, E. F., Meyer, F. B., & Hallett, J. W. (2000) · Mayo Clinic Proceedings · doi:10.4065/75.11.1133 · Cited by 100
Kagawa, R., Moritake, K., Shima, T., et al. (1996) · Stroke · doi:10.1161/01.str.27.4.700 · Cited by 93
Duplex Ultrasound Criteria for the Identification of Carotid Stenosis Should Be Laboratory Specific
Kuntz, K. M., Polak, J. F., Whittemore, A. D., Skillman, J. J., & Kent, K. C. (1997) · Stroke · doi:10.1161/01.str.28.3.597 · Cited by 91
Young, G. R., Humphrey, P. R. D., Shaw, M. D. M., Nixon, T. E., & Smith, E. (1994) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.57.12.1466 · Cited by 86
Jackson, M. R., Chang, A. S., Robles, H. A., Gillespie, D. L., Olsen, S. B., Kaiser, W. J., Goff, J. M., O'Donnell, S. D., & Rich, N. M. (1998) · Annals of Vascular Surgery · doi:10.1007/s100169900146 · Cited by 75
Qureshi, A. I., Suri, M. F. K., Ali, Z., Kim, S. H., Fessler, R. D., Ringer, A. J., Guterman, L. R., Budny, J. L., & Hopkins, L. N. (2001) · Stroke · doi:10.1161/hs1001.096613 · Cited by 74
Nederkoorn, P. J., Elgersma, O. E. H., Mali, W. P. T. M., Eikelboom, B. C., Kappelle, L. J., & van der Graaf, Y. (2002) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(02)00137-4 · Cited by 73
Self-citationAccuracy of duplex sonography before carotid endarterectomy — A comparison with angiography
Hansen, F., Bergqvist, D., Lindblad, B., Lindh, M., Mätzsch, T., & Länne, T. (1996) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/s1078-5884(96)80252-8 · Cited by 54
Cinà, C. S., Clase, C. M., & Haynes, B. R. (1999) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(99)70100-x · Cited by 47
Dippel, D. W. J., de Kinkelder, A., Bakker, S. L. M., van Kooten, F., van Overhagen, H., & Koudstaal, P. J. (1999) · Neuroradiology · doi:10.1007/s002340050694 · Cited by 16
Magnetic resonance angiography or IADSA for diagnosis of carotid pseudo occlusion?
Currie, I. C., Murphy, K., Jones, A. J., Cole, S. E. A., Wakeley, C. J., Wilson, Y. G., Baird, R. N., & Lamont, P. M. (1994) · European Journal of Vascular Surgery · doi:10.1016/s0950-821x(05)80591-2 · Cited by 11
Comparison of MR angiography with contrast angiography for the diagnosis of carotid artery stenosis.
Dadachanji, M. C., Shroff, M. M., Modi, D., et al. (1995) · PubMed · Cited by 6
Explaining heterogeneity in meta-analysis: a comparison of methods
Thompson, S. G., & Sharp, S. J. (1999) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19991030)18:20
Cited by
Guidelines for Management of Ischaemic Stroke and Transient Ischaemic Attack 2008
(2008) · Cerebrovascular Diseases · doi:10.1159/000131083 · Cited by 2,489
Updated Society for Vascular Surgery guidelines for management of extracranial carotid disease
Ricotta, J. J., AbuRahma, A., Ascher, E., Eskandari, M., Faries, P., & Lal, B. K. (2011) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2011.07.031 · Cited by 611
Evidence of bias and variation in diagnostic accuracy studies
Rutjes, A. W. S., Reitsma, J. B., Di Nisio, M., Smidt, N., van Rijn, J. C., & Bossuyt, P. M. M. (2006) · Canadian Medical Association Journal · doi:10.1503/cmaj.050090 · Cited by 611
Alberts, M. J., Latchaw, R. E., Selman, W. R., Shephard, T., Hadley, M. N., Brass, L. M., Koroshetz, W., Marler, J. R., Booss, J., Zorowitz, R. D., et al. (2005) · Stroke · doi:10.1161/01.str.0000170622.07210.b4 · Cited by 585
Metadata
- Authors
- Nederkoorn, P. J., van der Graaf, Y., & Hunink, M. G. M.
- Venue
- Stroke
- Published
- 2003-05
- Volume
- 34
- Issue
- 5
- Pages
- 1324-1331
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2044717438
- Cited by
- 382
- References
- 35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.