The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Measurement of Carotid Plaque Volume by 3-Dimensional Ultrasound
Open accessAbstract
Background and PurposeMeasurement of carotid plaque volume and its progression are important tools for research and patient management. In this study, we investigate the observer variability in the measurement of plaque volume as determined by 3-dimensional (3D) ultrasound (US). We also investigate the effect of interslice distances (ISD) and repeated 3D US scans on measurement variability. Materials and MethodsForty 3D US patient images of plaques (range, 37.43 to 604.1 mm 3) were measured by manual planimetry. We applied ANOVA to determine plaque volume measurement variability and reliability. Plaque volumes were measured with 9 ISDs to determine the effect of ISD on measurement variability. Additional plaque volumes were also measured from multiple 3D US scans to investigate repeated scan acquisition variability. ResultsIntraobserver and interobserver measurement reliabilities were 94% and 93.2%, respectively. Plaque volume measurement variability decreased with increasing plaque volume (range, 27.1% to 2.2%). Measurement precision was constant for ISDs between 1.0 and 3.0 mm, whereas plaque volume measurement variability increased with ISD. Repeated 3D US scan measurements were not different from single-scan measurements (P=0.867). ConclusionsThe coefficient of variation in the measurement of plaque volume decreased with plaque size. The volumetric change that must be observed to establish with 95% confidence that a plaque has undergone change is ≈20% to 35% for plaques <100 mm 3 and ≈10% to 20% for plaques >100 mm 3. Measurement precision was unchanged for ISDs <3.0 mm, whereas measurement variability increased with ISD. Repeated 3D US scans did not affect plaque volume measurement variability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Three-dimensional ultrasound imaging
Fenster, A., Downey, D. B., & Cardinal, H. N. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/5/201 · Cited by 812
Self-citation
Cited by
Johri, A. M., Nambi, V., Naqvi, T. Z., Feinstein, S. B., Kim, E. S. H., Park, M. M., Becher, H., & Sillesen, H. (2020) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2020.04.021 · Cited by 370
Ainsworth, C. D., Blake, C. C., Tamayo, A., Beletsky, V., Fenster, A., & Spence, J. D. (2005) · Stroke · doi:10.1161/01.str.0000178543.19433.20 · Cited by 263
Self-citationGeneral principles of carotid Doppler ultrasonography
Lee, W. (2013) · Ultrasonography · doi:10.14366/usg.13018 · Cited by 134
Short-term progression of multiterritorial subclinical atherosclerosis
López-Melgar, B., Fernández-Friera, L., Oliva, B., García-Ruiz, J. M., Sánchez-Cabo, F., Bueno, H., Mendiguren, J. M., Lara-Pezzi, E., Andrés, V., Ibáñez, B., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.02.026 · Cited by 103
Metadata
- Authors
- Landry, A., Spence, J. D., & Fenster, A.
- Venue
- Stroke
- Published
- 2004-04
- Volume
- 35
- Issue
- 4
- Pages
- 864-869
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2005219553
- Cited by
- 212
- References
- 1
- FWCI
- 9.89
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of Carotid Plaque Volume by 3-Dimensional Ultrasound. https://app.cochat.ai/papers/10.1161/01.str.0000121161.61324.ab
- The paper
- Landry, A., Spence, J. D., & Fenster, A. (2004). Measurement of Carotid Plaque Volume by 3-Dimensional Ultrasound. Stroke. https://doi.org/10.1161/01.str.0000121161.61324.ab
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.