The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
3D Ultrasound Measurement of Change in Carotid Plaque Volume: A Tool for Rapid Evaluation of New Therapies
Open accessAbstract
Background and Purpose— New therapies are being developed that are antiatherosclerotic but that lack intermediate end points, such as changes in plasma lipids, which can be measured to test efficacy. To study such treatments, it will be necessary to directly measure changes in atherosclerosis. The study was designed to determine sample sizes needed to detect effects of treatment using 3D ultrasound (US) measurement of carotid plaque. Methods— In 38 patients with carotid stenosis >60%, age±SD 69.42±7.87 years, 15 female, randomly assigned in a double-blind fashion to 80 mg atorvastatin daily (n=17) versus placebo (n=21), we measured 3D plaque volume at baseline and after 3 months by disc segmentation of voxels representing carotid artery plaque, after 3D reconstruction of parallel transverse duplex US scans into volumetric 3D data sets. Results— There were no significant differences in baseline risk factors. The rate of progression was 16.81±74.10 mm 3 in patients taking placebo versus regression of −90.25±85.12 mm 3 in patients taking atorvastatin ( P <0.0001) Conclusions— 3D plaque volume measurement can show large effects of therapy on atherosclerosis in 3 months in sample sizes of ≈20 patients per group. Sample sizes of 22 per group would be sufficient to show an effect size of 25% that of atorvastatin in 6 months. This technology promises to be very useful in evaluation of new therapies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
O'Leary, D. H., Polak, J. F., Kronmal, R. A., Manolio, T. A., Burke, G. L., & Wolfson, S. K. (1999) · New England Journal of Medicine · doi:10.1056/nejm199901073400103 · Cited by 4,685
Nissen, S. E., Tuzcu, E. M., Schoenhagen, P., Brown, B. G., Ganz, P., Vogel, R. A., Crowe, T., Howard, G., Cooper, C. J., Brodie, B., et al. (2004) · JAMA · doi:10.1001/jama.291.9.1071 · Cited by 2,361
Nissen, S. E., Tsunoda, T., Tuzcu, E. M., Schoenhagen, P., Cooper, C. J., Yasin, M., Eaton, G. M., Lauer, M. A., Sheldon, W. S., Grines, C. L., et al. (2003) · JAMA · doi:10.1001/jama.290.17.2292 · Cited by 1,707
Cai, J.-M., Hatsukami, T. S., Ferguson, M. S., Small, R., Polissar, N. L., & Yuan, C. (2002) · Circulation · doi:10.1161/01.cir.0000028591.44554.f9 · Cited by 817
Carotid Plaque Area: A Tool for Targeting and Evaluating Vascular Preventive Therapy
Spence, J. D., Eliasziw, M., DiCicco, M., Hackam, D. G., Galil, R., & Lohmann, T. (2002) · Stroke · doi:10.1161/01.str.0000042207.16156.b9 · Cited by 587
Self-citationPsychological stress and the progression of carotid artery disease
Barnett, P. A., Spence, J. D., Manuck, S. B., & Jennings, J. R. (1997) · Journal of Hypertension · doi:10.1097/00004872-199715010-00004 · Cited by 418
Self-citationBots, M. L., Evans, G. W., Riley, W. A., & Grobbee, D. E. (2003) · Stroke · doi:10.1161/01.str.0000102044.27905.b5 · Cited by 379
Measurement of Carotid Plaque Volume by 3-Dimensional Ultrasound
Landry, A., Spence, J. D., & Fenster, A. (2004) · Stroke · doi:10.1161/01.str.0000121161.61324.ab · Cited by 212
Self-citationNoninvasive Phenotypes of Atherosclerosis
Spence, J. D., & Hegele, R. A. (2004) · Stroke · doi:10.1161/01.str.0000116103.19029.db · Cited by 154
Self-citationMineral Exploration: Search for the Mechanism of Vascular Calcification and Beyond
Demer, L. L., & Tintut, Y. (2003) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/01.atv.0000093547.63630.0f · Cited by 150
Cited by
Vlachopoulos, C., Xaplanteris, P., Aboyans, V., Brodmann, M., Cífková, R., Cosentino, F., De Carlo, M., Gallino, A., Landmesser, U., Laurent, S., et al. (2015) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2015.05.007 · Cited by 716
Carotid Intima-Media Thickness and Plaque in Cardiovascular Risk Assessment
Naqvi, T. Z., & Lee, M.-S. (2014) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2013.11.014 · Cited by 649
Johri, A. M., Nambi, V., Naqvi, T. Z., Feinstein, S. B., Kim, E. S. H., Park, M. M., Becher, H., & Sillesen, H. (2020) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2020.04.021 · Cited by 370
A Review on Real-Time 3D Ultrasound Imaging Technology
Huang, Q., & Zeng, Z. (2017) · BioMed Research International · doi:10.1155/2017/6027029 · Cited by 334
Carotid plaque, a subclinical precursor of vascular events: The Northern Manhattan Study
Rundek, T., Arif, H., Boden-Albala, B., Elkind, M. S., Paik, M. C., & Sacco, R. L. (2008) · Neurology · doi:10.1212/01.wnl.0000303969.63165.34 · Cited by 302
Metadata
- Authors
- Ainsworth, C. D., Blake, C. C., Tamayo, A., Beletsky, V., Fenster, A., & Spence, J. D.
- Venue
- Stroke
- Published
- 2005-09
- Volume
- 36
- Issue
- 9
- Pages
- 1904-1909
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2021502550
- Cited by
- 263
- References
- 23
- FWCI
- 10.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 3D Ultrasound Measurement of Change in Carotid Plaque Volume: A Tool for Rapid Evaluation of New Therapies. https://app.cochat.ai/papers/10.1161/01.str.0000178543.19433.20
- The paper
- Ainsworth, C. D., Blake, C. C., Tamayo, A., Beletsky, V., Fenster, A., & Spence, J. D. (2005). 3D Ultrasound Measurement of Change in Carotid Plaque Volume: A Tool for Rapid Evaluation of New Therapies. Stroke. https://doi.org/10.1161/01.str.0000178543.19433.20
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.