Systematic Review of Computed Tomographic Angiography for Assessment of Carotid Artery Disease
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Background and Purpose— To review the literature on the diagnostic accuracy of computed tomographic angiography (CTA) compared with arteriography/intra-arterial digital subtraction angiography as reference standard for assessment of symptomatic carotid artery disease. Methods— The PubMed, MEDLINE, PREMEDLINE, EMBASE, and CINAHL databases were searched to retrieve studies published between 1990 and July 2003, comparing CTA and intra-arterial digital subtraction angiography in patients with symptomatic carotid artery disease that presented raw data for detection of a <70% or 70% to 99% stenosis or an occlusion. Two observers independently assessed methodological quality and constructed 2×2 tables for sensitivity and specificity of CTA for detection of a 70% to 99% stenosis versus <70% stenosis or an occlusion, and for <99% stenosis versus occlusion. A bivariate random effects model was used to calculate the pooled sensitivity and specificity of CTA for detection of these lesions. Results— Some 864 patients (66% male) with a mean age of 66 years were studied in the 28 studies included in the meta-analysis. In all studies, a single-slice CT-scan was used. Only 8 studies satisfied all methodological quality criteria. The pooled sensitivity and specificity for detection of a 70% to 99% stenosis were 85% (95% CI, 79% to 89%) and 93% (95% CI, 89% to 96%), respectively. For detection of an occlusion, the sensitivity and specificity were 97% (95% CI, 93% to 99%) and 99% (95% CI, 98% to 100%), respectively. Incomplete reporting of demographic characteristics and technical differences in the individual studies obstructed a meaningful subgroup analysis. Conclusions— CTA is an accurate modality for detection of severe carotid artery disease, especially for detection of occlusions. The fair methodological quality of the included studies must be taken into account when interpreting these results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Self-citationTowards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Self-citationTowards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Self-citationEmpirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861
Rothwell, P., Eliasziw, M., Gutnikov, S., Fox, A., Taylor, D., Mayberg, M., Warlow, C., & Barnett, H. (2003) · The Lancet · doi:10.1016/s0140-6736(03)12228-3 · Cited by 1,696
Advanced methods in meta‐analysis: multivariate approach and meta‐regression
van Houwelingen, H. C., Arends, L. R., & Stijnen, T. (2002) · Statistics in Medicine · doi:10.1002/sim.1040 · Cited by 1,580
Willinsky, R. A., Taylor, S. M., terBrugge, K., Farb, R. I., Tomlinson, G., & Montanera, W. (2003) · Radiology · doi:10.1148/radiol.2272012071 · Cited by 895
McAuley, L., Pham, B., Tugwell, P., & Moher, D. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02786-0 · Cited by 812
Use of methodological standards in diagnostic test research. Getting better but still not good
Reid, M. C. (1995) · JAMA · doi:10.1001/jama.274.8.645 · Cited by 712
Asymmetric funnel plots and publication bias in meta-analyses of diagnostic accuracy
Song, F., Khan, K. S., Dinnes, J., & Sutton, A. J. (2002) · International Journal of Epidemiology · doi:10.1093/ije/31.1.88 · Cited by 484
Cited by
Reitsma, J. B., Glas, A. S., Rutjes, A. W. S., Scholten, R. J. P. M., Bossuyt, P. M., & Zwinderman, A. H. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.02.022 · Cited by 3,369
“Several examples of the bivariate model have already been published [39– 42].”
MethodSelf-citationMeschia, J. F., Bushnell, C., Boden-Albala, B., Braun, L. T., Bravata, D. M., Chaturvedi, S., Creager, M. A., Eckel, R. H., Elkind, M. S. V., Fornage, M., et al. (2014) · Stroke · doi:10.1161/str.0000000000000046 · Cited by 2,650
Goldstein, L. B., Bushnell, C. D., Adams, R. J., Appel, L. J., Braun, L. T., Chaturvedi, S., Creager, M. A., Culebras, A., Eckel, R. H., Hart, R. G., et al. (2011) · Stroke · doi:10.1161/str.0b013e3181fcb238 · Cited by 1,306
Updated Society for Vascular Surgery guidelines for management of extracranial carotid disease
Ricotta, J. J., AbuRahma, A., Ascher, E., Eskandari, M., Faries, P., & Lal, B. K. (2011) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2011.07.031 · Cited by 611
Brott, T. G., Halperin, J. L., Abbara, S., Bacharach, J. M., Barr, J. D., Bush, R. L., Cates, C. U., Creager, M. A., Fowler, S. B., Friday, G., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.11.006 · Cited by 447
Wardlaw, J., Chappell, F., Best, J., Wartolowska, K., & Berry, E. (2006) · The Lancet · doi:10.1016/s0140-6736(06)68650-9 · Cited by 375
ACCF/SCAI/SVMB/SIR/ASITN 2007 Clinical Expert Consensus Document on Carotid Stenting
Bates, E. R., Babb, J. D., Casey, D. E., Cates, C. U., Duckwiler, G. R., Feldman, T. E., Gray, W. A., Ouriel, K., Peterson, E. D., Rosenfield, K., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.10.021 · Cited by 310
Aetiological diagnosis of ischaemic stroke in young adults
Ferro, J. M., Massaro, A. R., & Mas, J.-L. (2010) · The Lancet Neurology · doi:10.1016/s1474-4422(10)70251-9 · Cited by 277
de Weert, T. T., Ouhlous, M., Meijering, E., Zondervan, P. E., Hendriks, J. M., van Sambeek, M. R. H. M., Dippel, D. W. J., & van der Lugt, A. (2006) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000240518.90124.57 · Cited by 231
“(4) Because the resolution of histological sections ( 7 7 5 m) cannot be achieved with MDCT ( 0.”
BackgroundCryptogenic Stroke: Research and Practice
Yaghi, S., Bernstein, R. A., Passman, R., Okin, P. M., & Furie, K. L. (2017) · Circulation Research · doi:10.1161/circresaha.116.308447 · Cited by 195
A review and critique of modelling in prioritising and designing screening programmes
Karnon, J., Goyder, E., Tappenden, P., McPhie, S., Towers, I., Brazier, J., & Madan, J. (2007) · Health Technology Assessment · doi:10.3310/hta11520 · Cited by 184
Vessel Wall Imaging of the Intracranial and Cervical Carotid Arteries
Choi, Y. J., Jung, S. C., & Lee, D. H. (2015) · Journal of Stroke · doi:10.5853/jos.2015.17.3.238 · Cited by 177
“org 247 accurate when diagnosing the degree of carotid occlusion (97% sensitivity and 99% specificity).(109) In terms of plaque morphology, the most relevant surface alteration that may be detected on CT angiography is ulceration (Figure 10).”
BackgroundImaging modalities to diagnose carotid artery stenosis: progress and prospect
Saxena, A., Ng, E. Y. K., & Lim, S. T. (2019) · BioMedical Engineering OnLine · doi:10.1186/s12938-019-0685-7 · Cited by 177
Writing Committee Members, Brott, T. G., Halperin, J. L., Abbara, S., Bacharach, J. M., Barr, J. D., Bush, R. L., Cates, C. U., Creager, M. A., Fowler, S. B., et al. (2011) · Stroke · doi:10.1161/str.0b013e3182112cc2 · Cited by 174
Mendrinos, E., Machinis, T. G., & Pournaras, C. J. (2010) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2009.02.024 · Cited by 169
Metadata
- Authors
- Koelemay, M. J. W., Nederkoorn, P. J., Reitsma, J. B., & Majoie, C. B.
- Venue
- Stroke
- Published
- 2004-10
- Volume
- 35
- Issue
- 10
- Pages
- 2306-2312
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2116353870
- Cited by
- 316
- References
- 24
- FWCI
- 2.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.