CoChat

Carotid Plaque Surface Irregularity Predicts Ischemic Stroke: The Northern Manhattan Study

Open access
Prabhakaran, Shyam, Rundek, Tatjana, Ramas, Romel, Elkind, Mitchell S.V., Paik, Myunghee Cho, Boden-Albala, Bernadette, Sacco, Ralph L. · 2006 · Stroke
Cited by 223

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

Abstract

Background and Purpose— There is scant population-based evidence regarding extracranial carotid plaque surface irregularity and ischemic stroke. Using a prospective cohort design, we evaluated the association of carotid plaque surface irregularity and the risk of ischemic stroke in a multiethnic population. Methods— High-resolution B-mode ultrasound of the carotid arteries was performed in 1939 stroke-free subjects (mean age 69±10.0 years; 59% women; 53% Hispanic, 25% black, 22% white). Plaque was defined as a focal protrusion 50% greater than the surrounding area and localized along the extracranial carotid tree (internal carotid artery/bifurcation vs common carotid artery). Plaque surface was categorized as regular or irregular. Cox proportional hazard models were used to assess the association of surface characteristics and the risk of ischemic stroke. Results— Among 1939 total subjects, carotid plaque was visualized in 56.3% (1 plaque: 21.6%, >1 plaque: 34.7%, irregular plaque: 5.5%). During a mean follow up of 6.2 years after ultrasound examination, 69 ischemic strokes occurred. Unadjusted cumulative 5-year risks of ischemic stroke were: 1.3%, 3.0%, and 8.5% for no plaque, regular plaque, and irregular plaque, respectively. After adjusting for demographics, traditional vascular risk factors, degree of stenosis, and plaque thickness, presence of irregular plaque (vs no plaque) was independently associated with ischemic stroke (Hazard ratio, 3.1; 95% CI, 1.1 to 8.5). Conclusions— The presence of irregular carotid plaque independently predicted ischemic stroke in a multiethnic cohort. Plaque surface irregularities assessed by B-mode ultrasonography may help identify intermediate- to high-risk individuals beyond their vascular risk assessed by the presence of traditional risk factors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.0000244780.82190.a4

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 223

Metadata

Authors
Prabhakaran, S., Rundek, T., Ramas, R., Elkind, M. S. V., Paik, M. C., Boden-Albala, B., & Sacco, R. L.
Venue
Stroke
Published
2006-11
Volume
37
Issue
11
Pages
2696-2701
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2133250075
Cited by
223
References
39
FWCI
8.86
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.