Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 320

The DOI matches its Crossref record.

Characteristics of patent foramen ovale associated with cryptogenic stroke. A biplane transesophageal echocardiographic study.

Homma, S, Di Tullio, M R, Sacco, R L, Mihalatos, D, Li Mandri, G, Mohr, J P·1994·Stroke

Abstract

Patent foramen ovale is associated with ischemic stroke in patients without a clearly identifiable etiology for stroke (cryptogenic stroke). Paradoxical embolization is thought to be a potential mechanism. However, patent foramen ovale is also found in patients with known cause of stroke. Therefore, using contrast transesophageal echocardiography, we characterized the patent foramen ovale in cryptogenic stroke patients to assess morphological factors that may contribute to paradoxical embolization. Contrast transesophageal echocardiographic studies of 74 consecutive patients referred for ischemic stroke were reviewed. Twenty-three patients with patent foramen ovale were identified. These patients were classified as having strokes of determined origin or cryptogenic strokes according to criteria developed for the Stroke Data Bank of the National Institute of Neurological Disorders and Stroke. Separation of septum primum from secundum and the number of microbubbles appearing in left atrium were then quantitated. These parameters were compared between patients with cryptogenic stroke and those with known cause of stroke. The patent foramen ovale dimension was significantly larger in patients with cryptogenic stroke compared with patients with an identifiable cause of stroke (2.1 +/- 1.7 mm versus 0.57 +/- 0.78 mm [mean +/- SD]; P < .01). The number of microbubbles was also greater in patients with cryptogenic stroke compared with patients with an identifiable cause of stroke (13.9 +/- 10.7 versus 1.6 +/- 0.8 [mean +/- SD]; P < .0005). Patients with cryptogenic stroke have larger patent foramen ovale with more extensive right-to-left interatrial shunting than patients with stroke of determined cause. Transesophageal echocardiographically identifiable characteristics of patent foramen ovale may be important in defining the clinical significance of individual patent foramina.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.25.3.582

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 320

Metadata

Authors
Homma, S., Di Tullio, M. R., Sacco, R. L., Mihalatos, D., Li Mandri, G., & Mohr, J. P.
Venue
Stroke
Published
1994-03
Volume
25
Issue
3
Pages
582-586
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W1997599767
Cited by
320
References
0
FWCI
6.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Characteristics of patent foramen ovale associated with cryptogenic stroke. A biplane transesophageal echocardiographic study. https://app.cochat.ai/papers/10.1161/01.str.25.3.582
The paper
Homma, S., Di Tullio, M. R., Sacco, R. L., Mihalatos, D., Li Mandri, G., & Mohr, J. P. (1994). Characteristics of patent foramen ovale associated with cryptogenic stroke. A biplane transesophageal echocardiographic study. Stroke. https://doi.org/10.1161/01.str.25.3.582

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.