CoChat

Slow Rhythmic Oscillations of Blood Pressure, Intracranial Pressure, Microcirculation, and Cerebral Oxygenation: Dynamic Interrelation and Time Course in Humans

Steinmeier, Ralf, Bauhuf, Christian, Hübner, Ulrich, Bauer, Rudolf Dietrich, Fahlbusch, Rudolf, Laumer, Rudolf, Bondar, Imre · 1996 · Stroke
Cited by 116

The DOI matches its Crossref record.

Abstract

Background and Purpose Various biological signals show nonpulsatile, slow rhythmic oscillations. These include arterial blood pressure (aBP), blood flow velocity in cerebral arteries, intracranial pressure (ICP), cerebral microflow, and cerebral tissue P o 2 . Generation and interrelations between these rhythmic fluctuations remained unclear. The aim of this study was to analyze whether stable dynamic interrelations in the low-frequency range exist between these different variables, and if they do, to analyze their exact time delay. Methods In a clinical study, 16 comatose patients with either higher-grade subarachnoid hemorrhage or severe traumatic brain injury were examined. A multimodal digital data acquisition system was used to simultaneously monitor aBP, flow velocity in the middle cerebral artery (FV MCA ), ICP, cerebral microflow, and oxygen saturation in the jugular bulb (Sj o 2 ). Cross-correlation as a means to analyze time delay and correlation between two periodic signals was applied to a time series of 30 minutes' duration divided into four segments of 2048 data points (≈436 seconds) each. This resulted in four cross-correlations for each 30-minute time series. If the four cross-correlations were consistent and reproducible, averaging of the original cross-correlations was performed, resulting in a representative time delay and correlation for the complete 30-minute interval. Results Reproducible cross-correlations and stable dynamic interrelations were found between aBP, FV MCA , ICP, and Sj o 2 . The mean time delay between aBP and ICP was 6.89±1.90 seconds, with a negative correlation in 81%. A mean time delay of 1.50±1.29 seconds (median, 0.85 seconds) was found between FV MCA and ICP, with a positive correlation in 94%. The mean delay between ICP and Sj o 2 was 9.47±2.21 seconds, with a positive correlation in 77%. Mean values of aBP and ICP did not influence the time delay and dynamic interrelation between the different parameters. Conclusions These results strongly support Rosner's theory that ICP B-waves are the autoregulatory response of spontaneous fluctuations of cerebral perfusion pressure. There is casuistic evidence that failure of autoregulation significantly modifies time delay and the correlation between aBP and ICP.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.27.12.2236

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Steinmeier, R., Bauhuf, C., Hübner, U., Bauer, R. D., Fahlbusch, R., Laumer, R., & Bondar, I.
Venue
Stroke
Published
1996-12
Volume
27
Issue
12
Pages
2236-2243
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2084441168
Cited by
116
References
0
FWCI
2.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.