Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 191

The DOI matches its Crossref record.

Indexes of Flow and Cross-sectional Area of the Middle Cerebral Artery Using Doppler Ultrasound During Hypoxia and Hypercapnia in Humans

Poulin, Marc J., Robbins, Peter A. · 1996 · Stroke

Abstract

Background and Purpose This study examined changes in cross-sectional area of the middle cerebral artery as assessed by changes in Doppler signal power during hypoxia and hypercapnia. In addition, it examined the degree of consistency among three indexes of cerebral blood flow and velocity: the velocity spectral outline (V̄ P ), the intensity-weighted mean velocity (V̄ IWM ), and an index of middle cerebral artery flow (P·V̄ IWM ). P·V̄ IWM was calculated as the product of V̄ IWM multiplied by the total power signal. Power is proportional to cross-sectional area of the vessel; this calculation therefore allows for any changes in this variable. Methods Four protocols were used, each repeated six times for six healthy adults aged 20.8±1.7 years (mean±SD). The first was a control protocol (A) with end-tidal P o 2 ( et P o 2 ) maintained at 100 mm Hg and et P co 2 at 1 to 2 mm Hg above eucapnia throughout. The second was a hypoxic step protocol (B) with et P o 2 lowered from control values to 50 mm Hg for 20 minutes. The third was a hypercapnic step protocol (C) with et P co 2 elevated from control by 7.5 mm Hg for 20 minutes. The fourth was a combined hypoxic and hypercapnic step protocol (D) lasting 20 minutes. A dynamic end-tidal forcing system was used to control et P co 2 and et P o 2 . Doppler data were collected and stored every 10 milliseconds, and mean values were determined later on a beat-by-beat basis. V̄ P , V̄ IWM , power, and P·V̄ IWM were expressed as a percentage of the average value over a 3-minute period before the step. Results In protocols A and B, there were no changes in power and there were no differences between V̄ P , V̄ IWM , and P·V̄ IWM . In C, at the relief from hypercapnia, there was a transient nonsignificant increase in power and a transient nonsignificant decrease in both V̄ P and V̄ IWM compared with P·V̄ IWM . In D, during the stimulus period, V̄ P was significantly higher than V̄ IWM (paired t test, P <.05), but both indexes were not different from P·V̄ IWM . In the period that followed relief from hypoxia and hypercapnia, the Doppler power signal was significantly increased by 3.8%. During this period, V̄ P and V̄ IWM were significantly lower than P·V̄ IWM . Conclusions At the levels of either hypoxia or hypercapnia used in this study, there were no changes in cross-sectional area of the middle cerebral artery, and changes in both V̄ P and V̄ IWM accurately reflect changes in P·V̄ IWM . With combined hypoxia and hypercapnia, however, at the relief from the stimuli when there is a very large and rapid decrease in P·V̄ IWM , power is increased, suggesting an increase in the cross-sectional area. During this period, changes in V̄ P and V̄ IWM underestimate the changes in P·V̄ IWM .

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.27.12.2244

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 191

Metadata

Authors
Poulin, M. J., & Robbins, P. A.
Venue
Stroke
Published
1996-12
Volume
27
Issue
12
Pages
2244-2250
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2108354433
Cited by
191
References
0
Type
paratext
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Indexes of Flow and Cross-sectional Area of the Middle Cerebral Artery Using Doppler Ultrasound During Hypoxia and Hypercapnia in Humans. https://app.cochat.ai/papers/10.1161/01.str.27.12.2244
The paper
Poulin, M. J., & Robbins, P. A. (1996). Indexes of Flow and Cross-sectional Area of the Middle Cerebral Artery Using Doppler Ultrasound During Hypoxia and Hypercapnia in Humans. Stroke. https://doi.org/10.1161/01.str.27.12.2244

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.