Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 303

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Assessment of middle cerebral artery diameter during hypocapnia and hypercapnia in humans using ultra-high-field MRI

Verbree, Jasper, Bronzwaer, Anne-Sophie G. T., Ghariq, Eidrees, Versluis, Maarten J., Daemen, Mat J. A. P., van Buchem, Mark A., Dahan, Albert, van Lieshout, Johannes J., van Osch, Matthias J. P.·2014·Journal of Applied Physiology

Abstract

In the evaluation of cerebrovascular CO 2 reactivity measurements, it is often assumed that the diameter of the large intracranial arteries insonated by transcranial Doppler remains unaffected by changes in arterial CO 2 partial pressure. However, the strong cerebral vasodilatory capacity of CO 2 challenges this assumption, suggesting that there should be some changes in diameter, even if very small. Data from previous studies on effects of CO 2 on cerebral artery diameter [middle cerebral artery (MCA)] have been inconsistent. In this study, we examined 10 healthy subjects (5 women, 5 men, age 21–30 yr). High-resolution (0.2 mm in-plane) MRI scans at 7 Tesla were used for direct observation of the MCA diameter during hypocapnia, −1 kPa (−7.5 mmHg), normocapnia, 0 kPa (0 mmHg), and two levels of hypercapnia, +1 and +2 kPa (7.5 and 15 mmHg), with respect to baseline. The vessel lumen was manually delineated by two independent observers. The results showed that the MCA diameter increased by 6.8 ± 2.9% in response to 2 kPa end-tidal Pco 2 (Pet CO 2 ) above baseline. However, no significant changes in diameter were observed at the −1 kPa (−1.2 ± 2.4%), and +1 kPa (+1.4 ± 3.2%) levels relative to normocapnia. The nonlinear response of the MCA diameter to CO 2 was fitted as a continuous calibration curve. Cerebral blood flow changes measured by transcranial Doppler could be corrected by this calibration curve using concomitant Pet CO 2 measurements. In conclusion, the MCA diameter remains constant during small deviations of the Pet CO 2 from normocapnia, but increases at higher Pet CO 2 values.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00651.2014

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 303

Metadata

Authors
Verbree, J., Bronzwaer, A.-S. G. T., Ghariq, E., Versluis, M. J., Daemen, M. J. A. P., van Buchem, M. A., Dahan, A., van Lieshout, J. J., & van Osch, M. J. P.
Venue
Journal of Applied Physiology
Published
2014-11-15
Volume
117
Issue
10
Pages
1084-1089
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2154423320
Cited by
303
References
26
FWCI
19.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of middle cerebral artery diameter during hypocapnia and hypercapnia in humans using ultra-high-field MRI. https://app.cochat.ai/papers/10.1152/japplphysiol.00651.2014
The paper
Verbree, J., Bronzwaer, A.-S. G. T., Ghariq, E., Versluis, M. J., Daemen, M. J. A. P., van Buchem, M. A., Dahan, A., van Lieshout, J. J., & van Osch, M. J. P. (2014). Assessment of middle cerebral artery diameter during hypocapnia and hypercapnia in humans using ultra-high-field MRI. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.00651.2014

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.