CoChat

Computerized Measurement of Motor Performance After Stroke

Cramer, Steven C., Nelles, Gereon, Schaechter, Judith D., Kaplan, Jill D., Finklestein, Seth P. · 1997 · Stroke
Cited by 42

The DOI matches its Crossref record.

Abstract

Background and Purpose Stroke scales usually convert motor status to a score along an ordinal scale and do not provide a permanent recording of motor performance. Computerized methods sensitive to small changes in neurological status may be of value for studying and measuring stroke recovery. Methods We developed a computerized dynamometer and tested 23 stroke subjects and 12 elderly control subjects on three motor tasks: sustained squeezing, repetitive squeezing, and index finger tapping. For each subject, scores on the Fugl-Meyer and National Institutes of Health stroke scales were also obtained. Results Sustained squeezing by the paretic hand of stroke subjects was weaker (9.2 kg) than the unaffected hand (20.2 kg; P <.0005), as well as control dominant (23.1 kg; P <.0005) and nondominant (19.9 kg; P <.005) hands. Paretic index finger tapping was slower (2.5 Hz) than the unaffected hand (4.2 Hz; P <.01), as well as control dominant (4.7 Hz; P <.0005) and nondominant (4.9 Hz; P <.0005) hands. Many features of dynamometer data correlated significantly with stroke subjects’ Fugl-Meyer scores, including sustained squeeze maximum force (ρ=.91) and integral of force over 5 seconds (ρ=.91); repetitive squeeze mean force (ρ=.92) and mean frequency (ρ=.73); and index finger tap mean frequency (ρ=.83). Correlation of these motor parameters with National Institutes of Health stroke scale score was weaker in all cases, a consequence of the scoring of nonmotor deficits on this scale. Dynamometer measurements showed excellent interrater ( r =.99) and intrarater ( r =.97) reliability. Conclusions The degree of motor deficit quantitated with the dynamometer is strongly associated with the extent of neurological abnormality measured with the use of two standardized stroke scales. The computerized dynamometer rapidly measures motor function along a continuous, linear scale and produces a permanent recording of hand motor performance accessible for subsequent analyses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.28.11.2162

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Cramer, S. C., Nelles, G., Schaechter, J. D., Kaplan, J. D., & Finklestein, S. P.
Venue
Stroke
Published
1997-11
Volume
28
Issue
11
Pages
2162-2168
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2160874724
Cited by
42
References
0
FWCI
1.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.