CoChat

The Stroke Prognosis Instrument II (SPI-II): A Clinical Prediction Instrument for Patients With Transient Ischemia and Nondisabling Ischemic Stroke

Kernan, Walter N., Viscoli, Catherine M., Brass, Lawrence M., Makuch, Robert W., Sarrel, Philip M., Roberts, Robin S., Gent, Michael, Rothwell, Peter, Sacco, Ralph L., Liu, Ruei-Che, Boden-Albala, Bernadette, Horwitz, Ralph I. · 2000 · Stroke
Cited by 206

The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.

Abstract

Background and Purpose —In 1991 we developed the Stroke Prognosis Instrument (SPI-I) to stratify patients with transient ischemic attack or ischemic stroke by prognosis for stroke or death in 2 years. In this article we validate and improve SPI-I (creating SPI-II). Methods —To validate SPI-I, we applied it to 4 test cohorts and calculated pooled outcome rates. To create SPI-II, we incorporated new predictive variables identified in 1 of the test cohorts and validated it in the other 3 cohorts. Results —For SPI-I, pooled rates (all 4 test cohorts) of stroke or death within 2 years in risk groups I, II, and III were 9%, 17%, and 24%, respectively ( P <0.01, log-rank test). SPI-II was created by adding congestive heart failure and prior stroke to SPI-I. Each patient’s risk group was determined by the total score for 7 factors: congestive heart failure (3 points); diabetes (3 points); prior stroke (3 points); age >70 years (2 points); stroke for the index event (not transient ischemic attack) (2 points); hypertension (1 point); and coronary artery disease (1 point). Risk groups I, II, and III comprised patients with 0 to 3, 4 to 7, and 8 to 15 points, respectively. For SPI-I, pooled rates (3 cohorts excluding the SPI-II development cohort) of stroke or death within 2 years in risk groups I, II, and III were 9%, 17%, and 23%, respectively. For SPI-II, pooled rates were 10%, 19%, and 31%, respectively. In receiver operator characteristic analysis, the area under the curve was 0.59 (95% CI, 0.57 to 0.60) for SPI-I and 0.63 (95% CI, 0.62 to 0.65) for SPI-II, confirming the better performance of the latter. Conclusions —Compared with SPI-I, SPI-II achieves greater discrimination in outcome rates among risk groups. SPI-II is ready for use in research design and may have a role in patient counseling.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.31.2.456

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 40 references

Cited by

See all 206

Metadata

Authors
Kernan, W. N., Viscoli, C. M., Brass, L. M., Makuch, R. W., Sarrel, P. M., Roberts, R. S., Gent, M., Rothwell, P., Sacco, R. L., Liu, R.-C., Boden-Albala, B., & Horwitz, R. I.
Venue
Stroke
Published
2000-02
Volume
31
Issue
2
Pages
456-462
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2016114416
Cited by
206
References
40
FWCI
2.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Stroke Prognosis Instrument II (SPI-II): A Clinical Prediction Instrument for Patients With Transient Ischemia and Nondisabling Ischemic Stroke. https://app.cochat.ai/papers/10.1161/01.str.31.2.456
The paper
Kernan, W. N., Viscoli, C. M., Brass, L. M., Makuch, R. W., Sarrel, P. M., Roberts, R. S., Gent, M., Rothwell, P., Sacco, R. L., Liu, R.-C., Boden-Albala, B., & Horwitz, R. I. (2000). The Stroke Prognosis Instrument II (SPI-II): A Clinical Prediction Instrument for Patients With Transient Ischemia and Nondisabling Ischemic Stroke. Stroke. https://doi.org/10.1161/01.str.31.2.456

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.