The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Objective Measurement of Functional Upper-Extremity Movement Using Accelerometer Recordings Transformed With a Threshold Filter
Abstract
Background and Purpose —The consensus is that the most important outcome for rehabilitation is functional activity in the life situation. Constraint-Induced Movement Therapy, a new treatment that transfers in-clinic gains to the life situation, demands objective measurement of real-world movement. However, direct, objective, and accurate measures of arm use in the real world are not available. Previous attempts to use accelerometry to measure extremity movement have failed because of unacceptable variability. This problem has been addressed here by use of a threshold filter. Methods —Nine stroke patients and 1 healthy individual wearing accelerometers were videotaped while they carried out their usual activities at home or in the clinic; the duration of their arm, torso, and ambulatory movements was judged by 2 observation teams. In addition, 11 college students performed 5 standardized activities of daily living for varying durations in the laboratory. The accelerometer data were transformed; the raw value recorded for a given epoch was set to a constant if it exceeded a low threshold. Results —The threshold-filtered recordings measured the duration of movement accurately and with very little variability. Correlations between the threshold-filtered recordings and the observer ratings of the duration of arm, torso, and ambulatory movements were 0.93, 0.93 and 0.99, respectively; the corresponding correlations for the raw values were −0.17, 0.34, and 0.85. Conclusions —These results present initial evidence for the validity of threshold-filtered accelerometer recordings for objectively measuring the amount of real-world upper-extremity movement as an index of treatment outcome for rehabilitation patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Cited by
Measuring orientation of human body segments using miniature gyroscopes and accelerometers
Luinge, H. J., & Veltink, P. H. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345966 · Cited by 647
Activity identification using body-mounted sensors—a review of classification techniques
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., Howard, D., Meijer, K., & Crompton, R. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/4/r01 · Cited by 600
Estimating Minimal Clinically Important Differences of Upper-Extremity Measures Early After Stroke
Lang, C. E., Edwards, D. F., Birkenmeier, R. L., & Dromerick, A. W. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2008.02.022 · Cited by 405
Lang, C. E., Bland, M. D., Bailey, R. R., Schaefer, S. Y., & Birkenmeier, R. L. (2013) · Journal of Hand Therapy · doi:10.1016/j.jht.2012.06.005 · Cited by 385
Ambulatory measurement of arm orientation
Luinge, H. J., Veltink, P. H., & Baten, C. T. M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.11.011 · Cited by 356
Metadata
- Authors
- Uswatte, G., Miltner, W. H. R., Foo, B., Varma, M., Moran, S., & Taub, E.
- Venue
- Stroke
- Published
- 2000-03
- Volume
- 31
- Issue
- 3
- Pages
- 662-667
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2107795307
- Cited by
- 232
- References
- 1
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Objective Measurement of Functional Upper-Extremity Movement Using Accelerometer Recordings Transformed With a Threshold Filter. https://app.cochat.ai/papers/10.1161/01.str.31.3.662
- The paper
- Uswatte, G., Miltner, W. H. R., Foo, B., Varma, M., Moran, S., & Taub, E. (2000). Objective Measurement of Functional Upper-Extremity Movement Using Accelerometer Recordings Transformed With a Threshold Filter. Stroke. https://doi.org/10.1161/01.str.31.3.662
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.