The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Objective Measurement of Functional Upper-Extremity Movement Using Accelerometer Recordings Transformed With a Threshold Filter
Abstract
Background and Purpose —The consensus is that the most important outcome for rehabilitation is functional activity in the life situation. Constraint-Induced Movement Therapy, a new treatment that transfers in-clinic gains to the life situation, demands objective measurement of real-world movement. However, direct, objective, and accurate measures of arm use in the real world are not available. Previous attempts to use accelerometry to measure extremity movement have failed because of unacceptable variability. This problem has been addressed here by use of a threshold filter. Methods —Nine stroke patients and 1 healthy individual wearing accelerometers were videotaped while they carried out their usual activities at home or in the clinic; the duration of their arm, torso, and ambulatory movements was judged by 2 observation teams. In addition, 11 college students performed 5 standardized activities of daily living for varying durations in the laboratory. The accelerometer data were transformed; the raw value recorded for a given epoch was set to a constant if it exceeded a low threshold. Results —The threshold-filtered recordings measured the duration of movement accurately and with very little variability. Correlations between the threshold-filtered recordings and the observer ratings of the duration of arm, torso, and ambulatory movements were 0.93, 0.93 and 0.99, respectively; the corresponding correlations for the raw values were −0.17, 0.34, and 0.85. Conclusions —These results present initial evidence for the validity of threshold-filtered accelerometer recordings for objectively measuring the amount of real-world upper-extremity movement as an index of treatment outcome for rehabilitation patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Cited by
Haghi, M., Thurow, K., & Stoll, R. (2017) · Healthcare Informatics Research · doi:10.4258/hir.2017.23.1.4 · Cited by 711
Measuring orientation of human body segments using miniature gyroscopes and accelerometers
Luinge, H. J., & Veltink, P. H. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345966 · Cited by 647
Activity identification using body-mounted sensors—a review of classification techniques
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., Howard, D., Meijer, K., & Crompton, R. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/4/r01 · Cited by 600
The Motor Activity Log-28: Assessing daily use of the hemiparetic arm after stroke
Uswatte, G., Taub, E., Morris, D., Light, K., & Thompson, P. A. (2006) · Neurology · doi:10.1212/01.wnl.0000238164.90657.c2 · Cited by 459
Self-citationvan der Lee, J. H., Beckerman, H., Knol, D. L., de Vet, H. C. W., & Bouter, L. M. (2004) · Stroke · doi:10.1161/01.str.0000126900.24964.7e · Cited by 456
Estimating Minimal Clinically Important Differences of Upper-Extremity Measures Early After Stroke
Lang, C. E., Edwards, D. F., Birkenmeier, R. L., & Dromerick, A. W. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2008.02.022 · Cited by 405
Lang, C. E., Bland, M. D., Bailey, R. R., Schaefer, S. Y., & Birkenmeier, R. L. (2013) · Journal of Hand Therapy · doi:10.1016/j.jht.2012.06.005 · Cited by 385
Ambulatory measurement of arm orientation
Luinge, H. J., Veltink, P. H., & Baten, C. T. M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.11.011 · Cited by 356
Inclination measurement of human movement using a 3-D accelerometer with autocalibration
Luinge, H. J., & Veltink, P. H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.822759 · Cited by 307
Monitoring of Physical Activity after Stroke: A Systematic Review of Accelerometry-Based Measures
Gebruers, N., Vanroy, C., Truijen, S., Engelborghs, S., & De Deyn, P. P. (2010) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2009.10.025 · Cited by 293
Winstein, C. J., Miller, J. P., Blanton, S., Taub, E., Uswatte, G., Morris, D., Nichols, D., & Wolf, S. (2003) · Neurorehabilitation and Neural Repair · doi:10.1177/0888439003255511 · Cited by 266
Self-citationHaaland, K. Y., Elsinger, C. L., Mayer, A. R., Durgerian, S., & Rao, S. M. (2004) · Journal of Cognitive Neuroscience · doi:10.1162/089892904323057344 · Cited by 260
Uswatte, G., Giuliani, C., Winstein, C., Zeringue, A., Hobbs, L., & Wolf, S. L. (2006) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2006.06.006 · Cited by 241
Self-citationUswatte, G., Foo, W. L., Olmstead, H., Lopez, K., Holand, A., & Simms, L. B. (2005) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2005.01.010 · Cited by 233
Self-citationUpper Extremity Use in People with Hemiparesis in the First Few Weeks After Stroke
Lang, C. E., Wagner, J. M., Edwards, D. F., & Dromerick, A. W. (2007) · Journal of Neurologic Physical Therapy · doi:10.1097/npt.0b013e31806748bd · Cited by 216
Michielsen, M. E., Selles, R. W., Stam, H. J., Ribbers, G. M., & Bussmann, J. B. (2012) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2012.03.016 · Cited by 139
Assessment of Arm Activity Using Triaxial Accelerometry in Patients With a Stroke
van der Pas, S. C., Verbunt, J. A., Breukelaar, D. E., van Woerden, R., & Seelen, H. A. (2011) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2011.02.021 · Cited by 131
de Niet, M., Bussmann, J. B., Ribbers, G. M., & Stam, H. J. (2007) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.06.005 · Cited by 94
Thrane, G., Emaus, N., Askim, T., & Anke, A. (2011) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0676 · Cited by 89
Measuring functional arm movement after stroke using a single wrist-worn sensor and machine learning
Bochniewicz, E. M., Emmer, G., McLeod, A., Barth, J., Dromerick, A. W., & Lum, P. (2017) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2017.07.004 · Cited by 73
Actigraphic Measurement of Motor Deficits in Acute Ischemic Stroke
Gebruers, N., Truijen, S., Engelborghs, S., Nagels, G., Brouns, R., & De Deyn, P. P. (2008) · Cerebrovascular Diseases · doi:10.1159/000160210 · Cited by 61
Predictive value of upper-limb accelerometry in acute stroke with hemiparesis
Gebruers, N., Truijen, S., Engelborghs, S., & De Deyn, P. P. (2013) · Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2012.09.0166 · Cited by 24
Tran, T., Chang, L.-C., Almubark, I., Bochniewicz, E. M., Shu, L., Lum, P. S., & Dromerick, A. (2018) · 2018 IEEE International Conference on Big Data (Big Data) · doi:10.1109/bigdata.2018.8622620 · Cited by 10
Metadata
- Authors
- Uswatte, G., Miltner, W. H. R., Foo, B., Varma, M., Moran, S., & Taub, E.
- Venue
- Stroke
- Published
- 2000-03
- Volume
- 31
- Issue
- 3
- Pages
- 662-667
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2107795307
- Cited by
- 232
- References
- 1
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.