Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 209

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Reproducibility of Computer-Quantified Carotid Plaque Echogenicity: Can We Overcome the Subjectivity?

Open access
Sabetai, M.M., Tegos, T.J., Nicolaides, A.N., Dhanjil, S., Pare, G.J., Stevens, J.M.·2000·Stroke

Abstract

Background and Purpose —We sought to assess the reproducibility, interobserver variability, and application to clinical studies of a new method for the quantitative assessment of carotid plaque echogenicity. Methods —Carotid plaques were scanned with the use of ultrasound, and their images were stored in a computer. They were normalized by assigning certain gray values to blood and adventitia, and the gray scale median (GSM) was used to quantify their echogenicity. The variability between storage media, between degrees of magnification, and between probes was assessed. The method was applied to 232 asymptomatic carotid plaques causing 60% to 99% stenosis in relation to the presence of ipsilateral CT-demonstrated brain infarcts. In all parts of the study the plaque GSM was measured before and after normalization to evaluate its effect. Interobserver agreement for the scanning process was assessed. Results —The GSM mean difference before and after normalization for variability studies of storage media, degrees of magnification, and probes was −14.5 and −0.12, 2.24 and 1.68, and −8.3 and −0.7, respectively. The median GSM of plaques associated with ipsilateral nonlacunar silent CT-demonstrated brain infarcts was 14, and that of plaques that were not so associated was 30 ( P =0.003). The interobserver GSM difference was −0.05 (95% CI, −1.7 to 1.6). Conclusions —Our method decreases the variability between storage media and between probes but not the variability between degrees of magnification. It separates echomorphologically the carotid plaques associated with silent nonlacunar CT-demonstrated brain infarcts from plaques that are not so associated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.31.9.2189

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 209

Metadata

Authors
Sabetai, M. M., Tegos, T. J., Nicolaides, A. N., Dhanjil, S., Pare, G. J., & Stevens, J. M.
Venue
Stroke
Published
2000-09
Volume
31
Issue
9
Pages
2189-2196
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2135493488
Cited by
209
References
2
FWCI
4.01
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reproducibility of Computer-Quantified Carotid Plaque Echogenicity: Can We Overcome the Subjectivity? https://app.cochat.ai/papers/10.1161/01.str.31.9.2189
The paper
Sabetai, M. M., Tegos, T. J., Nicolaides, A. N., Dhanjil, S., Pare, G. J., & Stevens, J. M. (2000). Reproducibility of Computer-Quantified Carotid Plaque Echogenicity: Can We Overcome the Subjectivity? Stroke. https://doi.org/10.1161/01.str.31.9.2189

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.