Esophageal Injury and Temperature Monitoring During Atrial Fibrillation Ablation
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
BACKGROUND: It is common practice to empirically limit the radiofrequency (RF) power when ablating the posterior left atrium during atrial fibrillation ablation to avoid thermal injury to the esophagus. The objective of this study was to determine whether RF energy delivery limited by luminal esophageal temperature (LET) monitoring is associated with a reduction in esophageal injury compared with a strategy of RF power limitation alone. METHODS AND RESULTS: Eighty-one consecutive patients who underwent atrial fibrillation ablation followed by esophageal endoscopy were included in this observational study. All patients underwent extraostial electric pulmonary vein isolation by using an electroanatomic mapping system and irrigated RF ablation. All RF applications on the posterior left atrium were limited to 35 W. A commercially available, single-thermocouple esophageal probe was used to monitor LET in a subset of patients (n=67). In these cases, applications were promptly interrupted when LET was > or =38.5 degrees C; further applications were performed at reduced power to obtain a LET < 38.5 degrees C. Esophageal endoscopy was performed 1 to 3 days after the procedure. Ablation-related esophageal ulcerations were identified in 9 of 81 (11%) patients. All patients were asymptomatic. Of these 81 patients, LET monitoring during ablation occurred in 67 (83%) of patients. Esophageal injury was observed more frequently (36% versus 6%, P<0.006) in the group without LET monitoring. CONCLUSIONS: These data suggest that LET monitoring may be associated with a reduction in esophageal injury compared with power limitation alone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pappone, C., Oral, H., Santinelli, V., Vicedomini, G., Lang, C. C., Manguso, F., Torracca, L., Benussi, S., Alfieri, O., Hong, R., et al. (2004) · Circulation · doi:10.1161/01.cir.0000131866.44650.46 · Cited by 871
Sánchez-Quintana, D., Cabrera, J. A., Climent, V., Farré, J., de Mendonça, M. C., & Ho, S. Y. (2005) · Circulation · doi:10.1161/circulationaha.105.551291 · Cited by 320 · cited 1×
“A major limitation of this approach is that it fails to account for the variability in the thickness of the posterior LA wall and the presence of peri-esophageal connective tissue – important determinants of esophageal heating (7, 14, 15).”
BackgroundLeft Atrial–Esophageal Fistula Following Radiofrequency Catheter Ablation of Atrial Fibrillation
SCANAVACCA, M. I., D'ÁVILA, A., PARGA, J., & SOSA, E. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.04083.x · Cited by 313 · cited 3×
“RF lesions extending beyond the atrial myocardium may result in collateral damage to adjacent structures, including the esophagus (2-7).”
BackgroundEsophageal perforation during left atrial radiofrequency ablation: Is the risk too high?
Doll, N., Borger, M. A., Fabricius, A., Stephan, S., Gummert, J., Mohr, F. W., Hauss, J., Kottkamp, H., & Hindricks, G. (2003) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2003.165 · Cited by 313
Esophageal injury during radiofrequency ablation for atrial fibrillation
Gillinov, A. M., Pettersson, G., & Rice, T. W. (2001) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2001.118041 · Cited by 293 · cited 1×
“While the pathophysiology is not fully understood, it is clear that thermal injury to the esophagus during ablation of the LA posterior wall plays a crucial role in triggering the cascade of events which eventually result in the development of LA-Eso fistula (8-10).”
BackgroundMohr, F. W., Fabricius, A. M., Falk, V., Autschbach, R., Doll, N., von Oppell, U., Diegeler, A., Kottkamp, H., & Hindricks, G. (2002) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2002.120730 · Cited by 268 · cited 1×
“While the pathophysiology is not fully understood, it is clear that thermal injury to the esophagus during ablation of the LA posterior wall plays a crucial role in triggering the cascade of events which eventually result in the development of LA-Eso fistula (8-10).”
BackgroundAutonomic nerve activity and atrial fibrillation
Chen, P.-S., & Tan, A. Y. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2006.12.006 · Cited by 231
Brief Communication: Atrial–Esophageal Fistulas after Radiofrequency Ablation
Cummings, J. E., Schweikert, R. A., Saliba, W. I., Burkhardt, J. D., Kilikaslan, F., Saad, E., & Natale, A. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-144-8-200604180-00007 · Cited by 212
Cummings, J. E., Schweikert, R. A., Saliba, W. I., Burkhardt, J. D., Brachmann, J., Gunther, J., Schibgilla, V., Verma, A., Dery, M., Drago, J. L., et al. (2005) · Circulation · doi:10.1161/circulationaha.104.509612 · Cited by 203 · cited 4×
“Similar to conclusions obtained by other investigators (11, 13), no relationship between RF power and LET was present.”
BackgroundMethodResultInfluentialAcute Pyloric Spasm and Gastric Hypomotility
Shah, D., Dumonceau, J.-M., Burri, H., Sunthorn, H., Schroft, A., Gentil-Baron, P., Yokoyama, Y., & Takahashi, A. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.04.030 · Cited by 171 · cited 1×
“which is difficult to ensure during the procedure; and (2)”
BackgroundEsophageal Temperature Monitoring During Radiofrequency Ablation of Atrial Fibrillation
Redfearn, D., Trim, G., Skanes, A. C., Petrellis, B., Krahn, A. D., Yee, R. K., & Klein, G. J. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.40825.x · Cited by 157 · cited 3×
“Similar to conclusions obtained by other investigators (11, 13), no relationship between RF power and LET was present.”
BackgroundResultTsuchiya, T., Ashikaga, K., Nakagawa, S., HAYASHIDA, K., & Kugimiya, H. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00693.x · Cited by 112
Cury, R. C., Abbara, S., Schmidt, S., Malchano, Z. J., Neužil, P., Weichet, J., Ferencik, M., Hoffmann, U., Ruskin, J. N., Brady, T. J., et al. (2005) · Heart Rhythm · doi:10.1016/j.hrthm.2005.09.012 · Cited by 108
Self-citationRipley, K. L., Gage, A. A., Olsen, D. B., Vleet, J. F. V., Lau, C., & Tse, H. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00790.x · Cited by 93 · cited 1×
“Alternative esophageal protective strategies: Alternative strategies described to avoid esophageal injury during AF ablation have included visualization of the esophagus with an enteral feeding tube, barium paste or electroanatomic mapping (19, 20), cooling of the esophagus to counter RF ablation-associated increases…”
Aupperle, H., Doll, N., Walther, T., Kornherr, P., Ullmann, C., Schoon, H., & Mohr, F. W. (2005) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2005.06.052 · Cited by 85 · cited 5×
“Currently, the most commonly employed clinical strategy to minimize esophageal thermal injury during AF ablation involves limiting the magnitude of power (25-35 Watts), as well as the duration (< 30 seconds), of RF applications placed along the posterior wall of the LA (11-13).”
BackgroundInfluentialMarrouche, N. F., Günther, J., Segerson, N. M., Daccarett, M., Rittger, H., Marschang, H., Schibgilla, V., Schmidt, M. U., Ritscher, G., Noelker, G., et al. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00879.x · Cited by 82
Perzanowski, C. A., Teplitsky, L., Hranitzky, P. M., & Bahnson, T. D. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.00333.x · Cited by 80
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Self-citationCalkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Metadata
- Authors
- Singh, S. M., d'Avila, A., Doshi, S. K., Brugge, W. R., Bedford, R. A., Mela, T., Ruskin, J. N., & Reddy, V. Y.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2008-08-01
- Volume
- 1
- Issue
- 3
- Pages
- 162-168
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2045142331
- Cited by
- 207
- References
- 17
- FWCI
- 9.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.