Efficacy of Antibiotic Prophylaxis Before the Implantation of Pacemakers and Cardioverter-Defibrillators: Results of a Large, Prospective, Randomized, Double-Blinded, Placebo-Controlled Trial
Abstract
Background— Although routinely administered, definitive evidence for the benefits of prophylactic antibiotics before the implantation of permanent pacemakers and implantable cardioverter-defibrillators from a large double-blinded placebo-controlled trial is lacking. The purpose of this study was to determine whether prophylactic antibiotic administration reduces the incidence of infection related to device implantation. Methods and Results— This double blinded study included 1000 consecutive patients who presented for primary device (Pacemaker and implantable cardioverter-defibrillators) implantation or generator replacement randomized in a 1:1 fashion to prophylactic antibiotics or placebo. Intravenous administration of 1 g of cefazolin (group I) or placebo (group 2) was done immediately before the procedure. Follow-up was performed 10 days, 1, 3, and 6 months after discharge. The primary end point was any evidence of infection at the surgical incision (pulse generator pocket), or systemic infection related to be procedure. The safety committee interrupted the trial after 649 patients were enrolled due to a significant difference in favor of the antibiotic arm (group I: 2 of 314 infected patients—0.63%; group II: 11 of 335 to 3.28%; RR=0.19 ; P =0.016). The following risk factors were positively correlated with infection by univariate analysis: nonuse of preventive antibiotic ( P =0.016); implant procedures (versus generator replacement: P =0.02); presence of postoperative hematoma ( P =0.03) and procedure duration ( P =0.009). Multivariable analysis identified nonuse of antibiotic ( P =0.037) and postoperative hematoma ( P =0.023) as independent predictors of infection. Conclusions— Antibiotic prophylaxis significantly reduces infectious complications in patients undergoing implantation of pacemakers or cardioverter-defibrillators.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cazeau, S., Leclercq, C., Lavergne, T., Walker, S., Varma, C., Linde, C., Garrigue, S., Kappenberger, L., Haywood, G. A., Santini, M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200103223441202 · Cited by 2,751
Durack, D. T., Lukes, A. S., Bright, D. K., & Service, D. E. (1994) · The American Journal of Medicine · doi:10.1016/0002-9343(94)90143-0 · Cited by 2,572
Treatment of Infections Associated with Surgical Implants
Darouiche, R. O. (2004) · New England Journal of Medicine · doi:10.1056/nejmra035415 · Cited by 2,257
Mirowski, M., Reid, P. R., Mower, M. M., Watkins, L., Gott, V. L., Schauble, J. F., Langer, A., Heilman, M. S., Kolenik, S. A., Fischell, R. E., et al. (1980) · New England Journal of Medicine · doi:10.1056/nejm198008073030607 · Cited by 1,361
Klug, D., Balde, M., Pavin, D., Hidden-Lucet, F., Clementy, J., Sadoul, N., Rey, J. L., Lande, G., Lazarus, A., Victor, J., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.678664 · Cited by 700
Systemic Infection Related to Endocarditis on Pacemaker Leads: Clinical Presentation and Management
Klug, D., Lacroix, D., Savoye, C., Goullard, L., Grandmougin, D., Hennequin, J. L., Kacet, S., & Lekieffre, J. (1997) · Circulation · doi:10.1161/01.cir.95.8.2098 · Cited by 593
Diagnosis and Management of Infections Involving Implantable Electrophysiologic Cardiac Devices
Chua, J. D., Wilkoff, B. L., Lee, I., Juratli, N., Longworth, D. L., & Gordon, S. M. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-133-8-200010170-00011 · Cited by 511
Implantable Left Ventricular Assist Devices
Goldstein, D. J., Oz, M. C., & Rose, E. A. (1998) · New England Journal of Medicine · doi:10.1056/nejm199811193392107 · Cited by 492
PARTIAL AND COMPLETE PROSTHESES IN AORTIC INSUFFICIENCY
Harken, D. E., Soroff, H. S., Taylor, W. J., Lefemine, A. A., Gupta, S. K., & Lunzer, S. (1960) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)32572-3 · Cited by 403
Increasing rates of cardiac device infections among medicare beneficiaries: 1990–1999
Cabell, C. H., Heidenreich, P. A., Chu, V. H., Moore, C. M., Stryjewski, M. E., Corey, G. R., & Fowler, V. G. (2004) · American Heart Journal · doi:10.1016/j.ahj.2003.06.005 · Cited by 397
Antibiotic Prophylaxis for Permanent Pacemaker Implantation: A Meta-Analysis
Da Costa, A., Kirkorian, G., Cucherat, M., Delahaye, F., Chevalier, P., Cerisier, A., Isaaz, K., & Touboul, P. (1998) · Circulation · doi:10.1161/01.cir.97.18.1796 · Cited by 362
Pacemaker Endocarditis Report of 44 Cases and Review of the Literature
Arber, N., Pras, E., Copperman, Y., Schapiro, J. M., Meiner, V., Lossos, I. S., Militianu, A., Hassin, D., Pras, E., Shai, A., et al. (1994) · Medicine · doi:10.1097/00005792-199411000-00003 · Cited by 251
Nonvalvular Infections of the Cardiovascular System
Kearney, R. A., Eisen, H. J., & Wolf, J. E. (1994) · Annals of Internal Medicine · doi:10.7326/0003-4819-121-3-199408010-00010 · Cited by 143
Hill, P. E. (1987) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1987.tb04521.x · Cited by 137
Ferguson, T. B., Ferguson, C. L., Crites, K., & Crimmins‐Reda, P. (1996) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(96)70334-3 · Cited by 84
Cited by
Habib, G., Lancellotti, P., Antunes, M. J., Bongiorni, M. G., Casalta, J.-P., Del Zotti, F., Dulgheru, R., El Khoury, G., Erba, P. A., Iung, B., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv319 · Cited by 4,997
Clinical practice guidelines for antimicrobial prophylaxis in surgery
Bratzler, D. W., Dellinger, E. P., Olsen, K. M., Perl, T. M., Auwaerter, P. G., Bolon, M. K., Fish, D. N., Napolitano, L. M., Sawyer, R. G., Slain, D., et al. (2013) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp120568 · Cited by 2,591
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
2023 ESC Guidelines for the management of endocarditis
Delgado, V., Ajmone Marsan, N., de Waha, S., Bonaros, N., Brida, M., Burri, H., Caselli, S., Doenst, T., Ederhy, S., Erba, P. A., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad193 · Cited by 1,754
Kusumoto, F. M., Schoenfeld, M. H., Wilkoff, B. L., Berul, C. I., Birgersdotter-Green, U. M., Carrillo, R., Cha, Y.-M., Clancy, J., Deharo, J.-C., Ellenbogen, K. A., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.09.001 · Cited by 1,199
Metadata
- Authors
- de Oliveira, J. C., Martinelli, M., Nishioka, S. A. D., Varejão, T., Uipe, D., Pedrosa, A. A. A., Costa, R., & Danik, S. B.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2009-02
- Volume
- 2
- Issue
- 1
- Pages
- 29-34
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2546704212
- Cited by
- 349
- References
- 15
- FWCI
- 21.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.