The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
ECG Criteria to Identify Epicardial Ventricular Tachycardia in Nonischemic Cardiomyopathy
Abstract
Background— ECG criteria identifying epicardial (EPI) origin for ventricular tachycardia (VT) in nonischemic cardiomyopathy have not been determined. Endocardial (ENDO) and EPI basal left ventricle fibrosis characterizes the VT substrate. Methods and Results— We assessed the QRS from 102 basal-superior/lateral EPI and 67 comparable ENDO pace maps in 14 patients with nonischemic cardiomyopathy. Pace mapping focused on low bipolar voltage areas. Published morphology criteria: q wave in lead I (QWLI) and no q waves in inferior leads and interval criteria: pseudo-delta wave ≥34 ms, intrinsicoid deflection time ≥85 ms, shortest RS complex ≥121 ms, and maximum deflection index ≥0.55 were assessed for ability to identify EPI origin. Sixteen EPI and 8 ENDO of the 34 mapped VTs (71%) in the study population and 14 EPI and 7 ENDO VTs from an 11-patient validation cohort were localized to basal-superior/lateral left ventricle and corroborated pacing data. A QWL1 was seen in EPI but not ENDO pace maps (91% versus 4%; P <0.001), identified 14 of 16 EPI VTs (sensitivity, 88%), and was seen in 1 of 8 ENDO VTs (specificity, 88%). None of the remaining criteria achieved similar sensitivity without specificity <50%. We identified 4 criteria (q waves in inferior leads, pseudo-delta wave ≥75 ms, maximum deflection index ≥0.59, and QWL1) having ≥95% specificity and ≥20% sensitivity in identifying EPI/ENDO origin for pace maps. This 4-step algorithm identified the origin in 109 of 115 pace maps (95%), 21 of 24 VTs (88%) in the study population, and 19 of 21 VTs (90%) in validation cohort. Conclusions— Morphological ECG features that describe the initial QRS vector can help identify basal-superior/lateral EPI VTs in nonischemic cardiomyopathy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Technique to Perform Epicardial Mapping in the Electrophysiology Laboratory
SOSA, E., SCANAVACCA, M., D'AVILA, A., & PILLEGGI, E. (1996) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1996.tb00559.x · Cited by 876
Soejima, K., Stevenson, W. G., Sapp, J. L., Selwyn, A. P., Couper, G., & Epstein, L. M. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.01.029 · Cited by 485
Daniels, D. V., Lu, Y.-Y., Morton, J. B., Santucci, P. A., Akar, J. G., Green, A., & Wilber, D. J. (2006) · Circulation · doi:10.1161/circulationaha.105.611640 · Cited by 380
Electrocardiographic Recognition of the Epicardial Origin of Ventricular Tachycardias
Berruezo, A., Mont, L., Nava, S., Chueca, E., Bartholomay, E., & Brugada, J. (2004) · Circulation · doi:10.1161/01.cir.0000125525.04081.4b · Cited by 368
Hsia, H. H., Callans, D. J., & Marchlinski, F. E. (2003) · Circulation · doi:10.1161/01.cir.0000083725.72693.ea · Cited by 368
Self-citationCano, O., Hutchinson, M., Lin, D., Garcia, F., Zado, E., Bala, R., Riley, M., Cooper, J., Dixit, S., Gerstenfeld, E., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.05.032 · Cited by 350
Self-citationSOSA, E., SCANAVACCA, M., D'AVILA, A., PICCIONI, J., SANCHEZ, O., VELARDE, J. L., SILVA, M., & REOLÃO, B. (1998) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1998.tb00907.x · Cited by 330
Bazan, V., Gerstenfeld, E. P., Garcia, F. C., Bala, R., Rivas, N., Dixit, S., Zado, E., Callans, D. J., & Marchlinski, F. E. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.07.004 · Cited by 185
Self-citationBazán, V., Bala, R., Garcia, F. C., SUSSMAN, J. S., Gerstenfeld, E. P., Dixit, S., Callans, D. J., Zado, E. S., & Marchlinski, F. E. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.06.024 · Cited by 129
Self-citationSwarup, V., Morton, J. B., Arruda, M., & Wilber, D. J. (2002) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2002.01164.x · Cited by 55
Cited by
Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
(2015) · Europace · doi:10.1093/europace/euv319 · Cited by 1,592
Jaïs, P., Maury, P., Khairy, P., Sacher, F., Nault, I., Komatsu, Y., Hocini, M., Forclaz, A., Jadidi, A. S., Weerasooryia, R., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.043216 · Cited by 645
2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2019) · EP Europace · doi:10.1093/europace/euz132 · Cited by 475
Self-citation2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2019.03.002 · Cited by 431
Self-citation
Metadata
- Authors
- Vallès, E., Bazan, V., & Marchlinski, F. E.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2010-02
- Volume
- 3
- Issue
- 1
- Pages
- 63-71
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2135819128
- Cited by
- 266
- References
- 11
- FWCI
- 9.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ECG Criteria to Identify Epicardial Ventricular Tachycardia in Nonischemic Cardiomyopathy. https://app.cochat.ai/papers/10.1161/circep.109.859942
- The paper
- Vallès, E., Bazan, V., & Marchlinski, F. E. (2010). ECG Criteria to Identify Epicardial Ventricular Tachycardia in Nonischemic Cardiomyopathy. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.109.859942
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.