The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Characterization of Endocardial Electrophysiological Substrate in Patients With Nonischemic Cardiomyopathy and Monomorphic Ventricular Tachycardia
Abstract
Background— Although catheter mapping has been used to define the endocardial electrogram characteristics in patients with ventricular tachycardia (VT) and coronary disease, characterization of the electrophysiological substrate in patients with VT and nonischemic cardiomyopathy is limited. Methods and Results— Left ventricular endocardial electroanatomical mapping was performed in 19 patients with nonischemic cardiomyopathy and monomorphic VT with an average of 178±83 sites per chamber mapped. Abnormal bipolar electrogram was defined as endocardial voltage signal amplitude of <1.8 mV. The extent and location of abnormal endocardium was estimated by measuring areas of abnormal electrogram recordings from 3D voltage maps. The origin of VT was approximated by identifying sites of entrainment with concealed fusion or early presystolic activity and/or by pace mapping. Abnormal electrograms were recorded over a 41±28 cm 2 area that represented 20±12% of total endocardial surface. The majority of patients (14/19 patients) had only a modest area (<25%) of endocardial abnormality. All patients had abnormal low-voltage endocardial areas located near the ventricular base in the perivalvular region. There were 3±1 VT morphologies per patient. The majority (88%) of the 57 mapped VTs originated from the ventricular base, corresponding to regions with abnormal endocardial electrograms. Conclusions— Electroanatomical mapping in patients with monomorphic VT and nonischemic cardiomyopathy typically demonstrates a modest-sized basal area of endocardial electrogram abnormalities. The VT site of origin corresponds to these basal electrogram abnormalities. These findings have important implications regarding strategies for VT ablation in this setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marchlinski, F. E., Callans, D. J., Gottlieb, C. D., & Zado, E. (2000) · Circulation · doi:10.1161/01.cir.101.11.1288 · Cited by 1,220
Self-citationStevenson, W. G., Khan, H., Sager, P., Saxon, L. A., Middlekauff, H. R., Natterson, P. D., & Wiener, I. (1993) · Circulation · doi:10.1161/01.cir.88.4.1647 · Cited by 909
Gepstein, L., Hayam, G., & Ben-Haim, S. A. (1997) · Circulation · doi:10.1161/01.cir.95.6.1611 · Cited by 759
Gardner, P. I., Ursell, P. C., Fenoglio, J. J., & Wit, A. L. (1985) · Circulation · doi:10.1161/01.cir.72.3.596 · Cited by 686
Dillon, S. M., Allessie, M. A., Ursell, P. C., & Wit, A. L. (1988) · Circulation Research · doi:10.1161/01.res.63.1.182 · Cited by 518
Recurrent sustained ventricular tachycardia. 2. Endocardial mapping.
Josephson, M. E., Horowitz, L. N., Farshidi, A., Spear, J. F., Kastor, J. A., & Moore, E. N. (1978) · Circulation · doi:10.1161/01.cir.57.3.440 · Cited by 372
Sosa, E., Scanavacca, M., d’Ávila, A., de Oliveira, F. R. G., & Ramires, J. A. F. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00606-9 · Cited by 309
Buxton, A. E., Waxman, H. L., Marchlinski, F. E., Untereker, W. J., Waspe, L. E., & Josephson, M. E. (1984) · Circulation · doi:10.1161/01.cir.69.3.532 · Cited by 258
Self-citationPogwizd, S. M., McKenzie, J. P., & Cain, M. E. (1998) · Circulation · doi:10.1161/01.cir.98.22.2404 · Cited by 243
Josephson, M. E., Waxman, H. L., CAIN, M. E., Gardner, M. J., & Buxton, A. E. (1982) · The American Journal of Cardiology · doi:10.1016/0002-9149(82)90003-0 · Cited by 229
Cited by
Zeppenfeld, K., Tfelt-Hansen, J., de Riva, M., Winkel, B. G., Behr, E. R., Blom, N. A., Charron, P., Corrado, D., Dagres, N., de Chillou, C., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac262 · Cited by 3,140
EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Della Bella, P., Hindricks, G., Jaïs, P., Josephson, M. E., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.030 · Cited by 770
Self-citationMapping and Ablation of Idiopathic Ventricular Fibrillation
Haïssaguerre, M., Shoda, M., Jaïs, P., Nogami, A., Shah, D. C., Kautzner, J., Arentz, T., Kalushe, D., Lamaison, D., Griffith, M., et al. (2002) · Circulation · doi:10.1161/01.cir.0000027564.55739.b1 · Cited by 686
Soejima, K., Stevenson, W. G., Sapp, J. L., Selwyn, A. P., Couper, G., & Epstein, L. M. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.01.029 · Cited by 485
2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2019.03.002 · Cited by 431
Self-citation
Metadata
- Authors
- Hsia, H. H., Callans, D. J., & Marchlinski, F. E.
- Venue
- Circulation
- Published
- 2003-08-12
- Volume
- 108
- Issue
- 6
- Pages
- 704-710
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2009116109
- Cited by
- 368
- References
- 16
- FWCI
- 5.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization of Endocardial Electrophysiological Substrate in Patients With Nonischemic Cardiomyopathy and Monomorphic Ventricular Tachycardia. https://app.cochat.ai/papers/10.1161/01.cir.0000083725.72693.ea
- The paper
- Hsia, H. H., Callans, D. J., & Marchlinski, F. E. (2003). Characterization of Endocardial Electrophysiological Substrate in Patients With Nonischemic Cardiomyopathy and Monomorphic Ventricular Tachycardia. Circulation. https://doi.org/10.1161/01.cir.0000083725.72693.ea
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.