Additional Ablation of Complex Fractionated Atrial Electrograms After Pulmonary Vein Isolation in Patients With Atrial Fibrillation: A Meta-Analysis
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background—: The efficacy of additional complex fractionated atrial electrogram (CFAE) ablation after pulmonary vein antrum isolation (PVAI) in patients with atrial fibrillation (AF) remains controversial. This meta-analysis was performed to assess the additional efficacy of CFAEs ablation after a single procedure without antiarrhythmic drugs. Methods and Results—: Trials were identified in MEDLINE, Cochrane Library, Embase, Google Scholar, reviews, and reference lists of relevant papers. Controlled cohort studies comparing the long-term efficacy of combined CFAEs plus PVAI ablation with PVAI alone were included. The primary end point was the maintenance of sinus rhythm without antiarrhythmic drugs. Seven controlled trials (9 comparisons) with a total of 622 participants (332 patients underwent PVAI plus CFAE ablation and 330 patients underwent PVAI alone) were included in the meta-analysis. In an overall pooled estimate, compared with PVI alone, long-term rates of sinus rhythm maintenance (relative risk, 1.17, 95% confidence interval, 1.03 to 1.33, P =0.019) were increased by additional CFAE ablation. Subgroup analysis demonstrated that additional CFAEs ablation increased rates of sinus rhythm maintenance in nonparoxysmal AF (relative risk, 1.35; 95% confidence interval, 1.04 to 1.75; P =0.022), whereas had no effect on patients with paroxysmal AF (relative risk, 1.04; 95% confidence interval, 0.92 to 1.18; P =0.528). Conclusions—: Adjuvant CFAE ablation in addition to standard PVAI increases the rate of long-term sinus rhythm maintenance in nonparoxysmal AF patients after a single procedure without antiarrhythmic drugs but does not provide additional benefit to sinus rhythm maintenance in paroxysmal AF patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
New ideas about atrial fibrillation 50 years on
Nattel, S. (2002) · Nature · doi:10.1038/415219a · Cited by 1,481
Atrial Tachycardia After Circumferential Pulmonary Vein Ablation of Atrial Fibrillation
Chae, S., Oral, H., Good, E., Dey, S., Wimmer, A., Crawford, T., Wells, D., Sarrazin, J.-F., Chalfoun, N., Kuhne, M., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.07.044 · Cited by 355
Cited by
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Di Biase, L., Mohanty, P., Mohanty, S., Santangeli, P., Trivedi, C., Lakkireddy, D., Reddy, M., Jais, P., Themistoclakis, S., Dello Russo, A., et al. (2016) · Circulation · doi:10.1161/circulationaha.115.019406 · Cited by 867
Ganesan, A. N., Shipp, N. J., Brooks, A. G., Kuklik, P., Lau, D. H., Lim, H. S., Sullivan, T., Roberts‐Thomson, K. C., & Sanders, P. (2013) · Journal of the American Heart Association · doi:10.1161/jaha.112.004549 · Cited by 800
“Comparisons to Previous Meta-analyses Over the years, a number of studies have addressed the shorter-term outcomes, predictors of recurrence,(28,29) or impact of specific types of ablation strategy.(35,36) The current study, for the first time, addresses the significant clinical issue of the long-term clinical outcome…”
Result
Metadata
- Authors
- Li, W.-J., Bai, Y.-Y., Zhang, H.-Y., Tang, R.-B., Miao, C.-L., Sang, C.-H., Yin, X.-D., Dong, J.-Z., & Ma, C.-S.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2011-04
- Volume
- 4
- Issue
- 2
- Pages
- 143-148
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2134740744
- Cited by
- 133
- References
- 2
- FWCI
- 12.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Additional Ablation of Complex Fractionated Atrial Electrograms After Pulmonary Vein Isolation in Patients With Atrial Fibrillation: A Meta-Analysis. https://app.cochat.ai/papers/10.1161/circep.110.958405
- The paper
- Li, W.-J., Bai, Y.-Y., Zhang, H.-Y., Tang, R.-B., Miao, C.-L., Sang, C.-H., Yin, X.-D., Dong, J.-Z., & Ma, C.-S. (2011). Additional Ablation of Complex Fractionated Atrial Electrograms After Pulmonary Vein Isolation in Patients With Atrial Fibrillation: A Meta-Analysis. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.110.958405
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.