Use of an Implantable Monitor to Detect Arrhythmia Recurrences and Select Patients for Early Repeat Catheter Ablation for Atrial Fibrillation: A Pilot Study
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Background—: Catheter ablation of atrial fibrillation (AF) has proved effective in curing highly symptomatic patients with paroxysmal AF. The aim of this prospective, randomized study was to identify the optimal treatment of patients with AF recurrences after the first ablation. Methods and Results—: Two hundred eighty-six patients with paroxysmal AF underwent ablation (circumferential pulmonary vein isolation with linear lesions) and were monitored with an implantable cardiac monitor (Reveal XT, Medtronic). Patients without AF recurrences during the 3-month postablation period were assigned to group 1; those with AF recurrences to group 2. Patients in group 2 were randomly assigned to group 3 or group 4. Group 3 patients were treated only with antiarrhythmic drugs for 6 weeks, with no early reablation during the 3-month postablation period. In the case of AF recurrence after the 3-month postablation period, patients underwent reablation. Group 4 patients were treated according to the onset mechanism of AF recurrences, as detected and stored by the implantable cardiac monitor: antiarrhythmic drug therapy, but no reablation if AF was not preceded by triggers; early reablation if premature atrial beats or atrial tachycardias or flutter triggered AF. All patients were followed up for 1 year to assess maintenance of sinus rhythm in each group. On 12-month follow-up examination, of the 119 (42%) patients in group 1, 112 (94%) had no AF recurrences. Among the 83 patients in group 3, only 27 (33%) had no recurrences. Of the 84 group 4 patients, 67 (80%) had no AF recurrences ( P <0.0001 versus group 3). Conclusions—: Patients with recurrences after the first AF ablation are likely to respond to a second early ablation when AF is triggered by supraventricular arrhythmias or premature contractions. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT01164319.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852 · cited 1×
“Diabetes mellitus, n (%) 7 (6) 14 (8) 0.”
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Wazni, O. M., Marrouche, N. F., Martin, D. O., Verma, A., Bhargava, M., Saliba, W., Bash, D., Schweikert, R., Brachmann, J., Gunther, J., et al. (2005) · JAMA · doi:10.1001/jama.293.21.2634 · Cited by 1,121 · cited 3×
“Inclusion criteria included (1) highly symptomatic patients refractory to at least 2 AADs (class I and class III) and (2) patients with sustained and ECG-documented PAF episodes ( 30 minutes).”
BackgroundGlotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Hilker, C., Miller, C., Qi, D., & Ziegler, P. D. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.849638 · Cited by 879
Calkins, H., Reynolds, M. R., Spector, P., Sondhi, M., Xu, Y., Martin, A., Williams, C. J., & Sledge, I. (2009) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.108.824789 · Cited by 847
Hindricks, G., Piorkowski, C., Tanner, H., Kobza, R., Gerds-Li, J.-H., Carbucicchio, C., & Kottkamp, H. (2005) · Circulation · doi:10.1161/circulationaha.104.518837 · Cited by 506
Hindricks, G., Pokushalov, E., Urban, L., Taborsky, M., Kuck, K.-H., Lebedev, D., Rieger, G., & Pürerfellner, H. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.877852 · Cited by 422
Self-citationBOTTO, G. L., PADELETTI, L., SANTINI, M., CAPUCCI, A., GULIZIA, M., ZOLEZZI, F., FAVALE, S., MOLON, G., RICCI, R., BIFFI, M., et al. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01320.x · Cited by 380
Self-citationSuppression of paroxysmal atrial tachyarrhythmias—results of the SOPAT trial
PATTEN, M., MAAS, R., BAUER, P., LUDERITZ, B., SONNTAG, F., DLUZNIEWSKI, M., HATALA, R., OPOLSKI, G., MULLER, H., & MEINERTZ, T. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.014 · Cited by 157
Hanke, T., Charitos, E. I., Stierle, U., Karluss, A., Kraatz, E., Graf, B., Hagemann, A., Misfeld, M., & Sievers, H. H. (2009) · Circulation · doi:10.1161/circulationaha.108.838474 · Cited by 121
Cited by
Boriani, G., Glotzer, T. V., Santini, M., West, T. M., De Melis, M., Sepsi, M., Gasparini, M., Lewalter, T., Camm, J. A., & Singer, D. E. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht491 · Cited by 427
Charitos, E. I., Stierle, U., Ziegler, P. D., Baldewig, M., Robinson, D. R., Sievers, H.-H., & Hanke, T. (2012) · Circulation · doi:10.1161/circulationaha.112.098079 · Cited by 196
“recently for more accurate detection of AF recurrence after ablation procedures or novel pharmacological strategies.(9) As expected, the sensitivity of these diagnostic modalities is close to 100% and, as such, is much superior to that of the currently employed 24-hour HM strategies.”
Sanders, P., Pürerfellner, H., Pokushalov, E., Sarkar, S., Di Bacco, M., Maus, B., & Dekker, L. R. C. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.03.005 · Cited by 162
Self-citation
Metadata
- Authors
- Pokushalov, E., Romanov, A., Corbucci, G., Artyomenko, S., Turov, A., Shirokova, N., & Karaskov, A.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2011-12
- Volume
- 4
- Issue
- 6
- Pages
- 823-831
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2133369189
- Cited by
- 87
- References
- 10
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of an Implantable Monitor to Detect Arrhythmia Recurrences and Select Patients for Early Repeat Catheter Ablation for Atrial Fibrillation: A Pilot Study. https://app.cochat.ai/papers/10.1161/circep.111.964809
- The paper
- Pokushalov, E., Romanov, A., Corbucci, G., Artyomenko, S., Turov, A., Shirokova, N., & Karaskov, A. (2011). Use of an Implantable Monitor to Detect Arrhythmia Recurrences and Select Patients for Early Repeat Catheter Ablation for Atrial Fibrillation: A Pilot Study. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.111.964809
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.