Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 218

The DOI matches its Crossref record.

One-Year Clinical Outcome After Pulmonary Vein Isolation Using the Second-Generation 28-mm Cryoballoon

Metzner, Andreas, Reissmann, Bruno, Rausch, Peter, Mathew, Shibu, Wohlmuth, Peter, Tilz, Roland, Rillig, Andreas, Lemes, Christine, Deiss, Sebastian, Heeger, Christian, Kamioka, Masashi, Lin, Tina, Ouyang, Feifan, Kuck, Karl-Heinz, Wissner, Erik · 2014 · Circulation: Arrhythmia and Electrophysiology

Abstract

Background—: The use of second-generation cryoballoon for pulmonary vein isolation in patients with paroxysmal atrial fibrillation has demonstrated encouraging acute and mid-term results. Long-term outcome data are not yet available. Methods and Results—: Fifty patients (18 women; mean age, 61±11 years; mean left atrial diameter, 43±5 mm) with paroxysmal (36 of 50 patients; 72%) or short-standing (<3-month duration) persistent atrial fibrillation (14 of 50 patients; 28%) underwent cryoballoon-based pulmonary vein isolation. Freeze cycle duration was 240 seconds. After successful pulmonary vein isolation, a bonus freeze was applied. Follow-up was based on outpatient clinic visits at 3, 6, and 12 months including Holter-ECGs and telephonic interviews. Recurrence was defined as a symptomatic or documented arrhythmia episode >30 seconds excluding a 3-month blanking period. A total of 192 pulmonary veins were identified, and 191 of 192 (99%) pulmonary veins were successfully isolated. Phrenic nerve palsy occurred in 1 of 50 (2%) patients. Follow-up was available for 49 of 50 (98%) patients with a mean follow-up duration of 440±39 days. Thirty-nine of 49 (80%) patients remained in stable sinus rhythm. Of 8 of 10 patients with arrhythmia recurrence, a second procedure using radiofrequency ablation demonstrated left atrial to pulmonary vein reconduction. Conclusions—: The use of second-generation 28-mm cryoballoon for pulmonary vein isolation results in an 80% 1-year success rate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.114.001473

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 218

Metadata

Authors
Metzner, A., Reissmann, B., Rausch, P., Mathew, S., Wohlmuth, P., Tilz, R., Rillig, A., Lemes, C., Deiss, S., Heeger, C., Kamioka, M., Lin, T., Ouyang, F., Kuck, K.-H., & Wissner, E.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2014-04
Volume
7
Issue
2
Pages
288-292
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W2120729749
Cited by
218
References
0
FWCI
26.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: One-Year Clinical Outcome After Pulmonary Vein Isolation Using the Second-Generation 28-mm Cryoballoon. https://app.cochat.ai/papers/10.1161/circep.114.001473
The paper
Metzner, A., Reissmann, B., Rausch, P., Mathew, S., Wohlmuth, P., Tilz, R., Rillig, A., Lemes, C., Deiss, S., Heeger, C., Kamioka, M., Lin, T., Ouyang, F., Kuck, K.-H., & Wissner, E. (2014). One-Year Clinical Outcome After Pulmonary Vein Isolation Using the Second-Generation 28-mm Cryoballoon. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.114.001473

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.