One-Year Clinical Outcome After Pulmonary Vein Isolation Using the Second-Generation 28-mm Cryoballoon
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Background—: The use of second-generation cryoballoon for pulmonary vein isolation in patients with paroxysmal atrial fibrillation has demonstrated encouraging acute and mid-term results. Long-term outcome data are not yet available. Methods and Results—: Fifty patients (18 women; mean age, 61±11 years; mean left atrial diameter, 43±5 mm) with paroxysmal (36 of 50 patients; 72%) or short-standing (<3-month duration) persistent atrial fibrillation (14 of 50 patients; 28%) underwent cryoballoon-based pulmonary vein isolation. Freeze cycle duration was 240 seconds. After successful pulmonary vein isolation, a bonus freeze was applied. Follow-up was based on outpatient clinic visits at 3, 6, and 12 months including Holter-ECGs and telephonic interviews. Recurrence was defined as a symptomatic or documented arrhythmia episode >30 seconds excluding a 3-month blanking period. A total of 192 pulmonary veins were identified, and 191 of 192 (99%) pulmonary veins were successfully isolated. Phrenic nerve palsy occurred in 1 of 50 (2%) patients. Follow-up was available for 49 of 50 (98%) patients with a mean follow-up duration of 440±39 days. Thirty-nine of 49 (80%) patients remained in stable sinus rhythm. Of 8 of 10 patients with arrhythmia recurrence, a second procedure using radiofrequency ablation demonstrated left atrial to pulmonary vein reconduction. Conclusions—: The use of second-generation 28-mm cryoballoon for pulmonary vein isolation results in an 80% 1-year success rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cryoballoon Ablation of Pulmonary Veins for Paroxysmal Atrial Fibrillation
Packer, D. L., Kowal, R. C., Wheelan, K. R., Irwin, J. M., Champagne, J., Guerra, P. G., Dubuc, M., Reddy, V., Nelson, L., Holcomb, R. G., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.064 · Cited by 899
Andrade, J. G., Khairy, P., Guerra, P. G., Deyell, M. W., Rivard, L., Macle, L., Thibault, B., Talajic, M., Roy, D., & Dubuc, M. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.03.050 · Cited by 360 · cited 1×
“5%(7) and thus comparable to the first-generation cryoballoon.(3) In our electrophysiology laboratories, only the 28-mm cryoballoon is used because of 2 reasons: first, our rate of acute PVI using only the 28-mm cryoballoon is 99%; second, the 28-mm cryoballoon is usually bigger than a normal-sized PV.”
BackgroundChun, K.-R. J., Schmidt, B., Metzner, A., Tilz, R., Zerm, T., Koster, I., Furnkranz, A., Koektuerk, B., Konstantinidou, M., Antz, M., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn570 · Cited by 350 · cited 1×
“However, results are compared with the outcome of a patient cohort from our center previously published using the first-generation 28-mm cryoballoon and a similar ablation protocol (1 bonus freeze cycle, 300-second freeze duration).(11,13)”
ResultSelf-citationFürnkranz, A., Bordignon, S., Schmidt, B., Gunawardene, M., Schulte‐Hahn, B., URBAN, V., Bode, F., Nowak, B., & Chun, J. (2013) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12082 · Cited by 202 · cited 10×
“Applying a single 180-second freeze cycle, 82% of patients remained in sinus rhythm.(4) In the current study, freeze cycle duration was 240 seconds, and after successful PVI, a bonus freeze of the same duration was applied.”
BackgroundMethodResultInfluentialLong-Term Outcomes After Cryoballoon Pulmonary Vein Isolation
Vogt, J., Heintze, J., Gutleben, K. J., Muntean, B. G., Horstkotte, D., & Nölker, G. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.09.033 · Cited by 166
Metzner, A., Rausch, P., Lemeš, C., Reißmann, B., Bardyszewski, A., Tilz, R. R., Rillig, A., Mathew, S., Deiß, S., Kamioka, M., et al. (2014) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12358 · Cited by 124 · cited 1×
“The intraluminal esophageal temperature cut-off was set at 10°C.(7) PVI using the second-generation 28mm CB The 28mm CB was advanced into the LA via the 12F steerable sheath using a spiral mapping catheter (15 mm or 20 mm diameter; Achieve, Medtronic, Inc.”
MethodSelf-citationChun, K. R. J., Fürnkranz, A., Köster, I., Metzner, A., Tönnis, T., Wohlmuth, P., Wißner, E., Schmidt, B., Ouyang, F. O., & Kück, K. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2012.02315.x · Cited by 52
Self-citation
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationCalkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Kuck, K.-H., Hoffmann, B. A., Ernst, S., Wegscheider, K., Treszl, A., Metzner, A., Eckardt, L., Lewalter, T., Breithardt, G., & Willems, S. (2016) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.115.003337 · Cited by 261
“The laser balloon technology has been shown to create durable lesions with a low gap rate at 3 months of only 15%,(30) and the second generation of the cryoballoon also seems to reduce reconduction.(31) Whether this translates into a higher clinical success rate needs further investigation in randomized clinical trial…”
BackgroundSelf-citation
Metadata
- Authors
- Metzner, A., Reissmann, B., Rausch, P., Mathew, S., Wohlmuth, P., Tilz, R., Rillig, A., Lemes, C., Deiss, S., Heeger, C., Kamioka, M., Lin, T., Ouyang, F., Kuck, K.-H., & Wissner, E.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2014-04
- Volume
- 7
- Issue
- 2
- Pages
- 288-292
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2120729749
- Cited by
- 218
- References
- 7
- FWCI
- 26.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.