Five-year outcome of catheter ablation of persistent atrial fibrillation using termination of atrial fibrillation as a procedural endpoint
Open accessAbstract
BACKGROUND: This study aimed to determine 5-year efficacy of catheter ablation for persistent atrial fibrillation (AF) using AF termination as a procedural end point. METHODS AND RESULTS: One hundred fifty patients (57±10 years) underwent persistent AF ablation using a stepwise ablation approach (pulmonary vein isolation, electrogram-guided, and linear ablation) with the desired procedural end point being AF termination. Repeat ablation was performed for recurrent AF or atrial tachycardia. AF was terminated by ablation in 120 patients (80%). Arrhythmia-free survival rates after a single procedure were 35.3%±3.9%, 28.0%±3.7%, and 16.8%±3.2% at 1, 2, and 5 years, respectively. Arrhythmia-free survival rates after the last procedure (mean 2.1±1.0 procedures) were 89.7%±2.5%, 79.8%±3.4%, and 62.9%±4.5%, at 1, 2, and 5 years, respectively. During a median follow-up of 58 (interquartile range, 43-73) months after the last ablation procedure, 97 of 150 (64.7%) patients remained in sinus rhythm without antiarrhythmic drugs. Another 14 (9.3%) patients maintained sinus rhythm after reinitiation of antiarrhythmic drugs, and an additional 15 (10.0%) patients regressed to paroxysmal recurrences only. Failure to terminate AF during the index procedure (hazard ratio 3.831; 95% confidence interval, 2.070-7.143; P<0.001), left atrial diameter≥50 mm (hazard ratio 2.083; 95% confidence interval, 1.078-4.016; P=0.03), continuous AF duration≥18 months (hazard ratio 1.984; 95% confidence interval, 1.024-3.846; P<0.04), and structural heart disease (hazard ratio 1.874; 95% confidence interval, 1.037-3.388; P=0.04) predicted arrhythmia recurrence. CONCLUSIONS: In patients with persistent AF, an ablation strategy aiming at AF termination is associated with freedom from arrhythmia recurrence in the majority of patients over a 5-year follow-up period. Procedural AF nontermination and specific baseline factors predict long-term outcome after ablation.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
There are insufficient data to guide the use of more extensive ablations in patients with persistent atrial fibrillation.
“More extensive ablations have been used in patients with persistent AF, but there are insufficient data to guide the use of these at present.117,718,719,[735][736][737]”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [719]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins.
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Mouroux, A. L., Métayer, P. L., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 8,040 · see citing works
Self-citation2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H. G., Cigarroa, J. E., Cleveland, J. C., CONTI, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000041 · Cited by 7,119 · see citing works
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852 · cited 1× · see citing works
“sistent with the current worldwide experience with this procedure.(1,22)”
BackgroundCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722 · see citing works
Self-citationNademanee, K., McKenzie, J. P., Kosar, E. M., Schwab, M., Sunsaneewitayakul, B., Vasavakul, T., Khunnawat, C., & Ngarmukos, T. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.12.054 · Cited by 2,004 · see citing works
Treatment of Atrial Fibrillation by the Ablation of Localized Sources
Narayan, S. M., Krummen, D. E., Shivkumar, K., Clopton, P., Rappel, W., & Miller, J. M. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.05.022 · Cited by 1,118 · see citing works
Haı̈ssaguerre, M., Hocini, M., Sanders, P., Sacher, F., Rotter, M., Takahashi, Y., Rostock, T., Hsu, L., Bordachar, P., Reuter, S., et al. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.00308.x · Cited by 755 · see citing works
Self-citationTechnique and Results of Linear Ablation at the Mitral Isthmus
Jaı̈s, P., Hocini, M., Hsu, L., Sanders, P., Scavée, C., Weerasooriya, R., Macle, L., Raybaud, F., Garrigue, S., Shah, D. C., et al. (2004) · Circulation · doi:10.1161/01.cir.0000146917.75041.58 · Cited by 751 · see citing works
Self-citationCatheter Ablation for Atrial Fibrillation
Weerasooriya, R., Khairy, P., Litalien, J., Macle, L., Hocini, M., Sacher, F., Lellouche, N., Knecht, S., Wright, M. J., Nault, I., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.05.061 · Cited by 735 · see citing works
Self-citationLong-Term Results of Catheter Ablation in Paroxysmal Atrial Fibrillation
Ouyang, F. O., Tilz, R. R., Chun, J., Schmidt, B., Wißner, E., Zerm, T., Neven, K. G. E. J., Köktürk, B., Konstantinidou, M., Metzner, A., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.946806 · Cited by 705 · see citing works
Haı̈ssaguerre, M., Sanders, P., Hocini, M., Takahashi, Y., Rotter, M., Sacher, F., Rostock, T., Hsu, L., Bordachar, P., Reuter, S., et al. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.00307.x · Cited by 675 · see citing works
Self-citationFúster, & Westerling, R. (2001) · Circulation · Cited by 607 · see citing works
Fuster, V., Rydén, L., ASINGER, R. W., Cannom, D. S., Crijns, H. J. G. M., Frye, R. L., Halperin, J. L., Kay, G. N., Klein, W. W., Lévy, S., et al. (2001) · Circulation · doi:10.1161/circ.104.17.2118 · Cited by 607 · see citing works
Hocini, M., Jaı̈s, P., Sanders, P., Takahashi, Y., Rotter, M., Rostock, T., Hsu, L., Sacher, F., Reuter, S., Clémenty, J., et al. (2005) · Circulation · doi:10.1161/circulationaha.105.541052 · Cited by 494 · see citing works
Self-citationOutcomes of long-standing persistent atrial fibrillation ablation: A systematic review
Brooks, A. G., Stiles, M. K., Laborderie, J., Lau, D. H., Kuklik, P., SHIPP, N. J., Hsu, L., & Sanders, P. (2010) · Heart Rhythm · doi:10.1016/j.hrthm.2010.01.017 · Cited by 488 · see citing works
Catheter Ablation of Long-Standing Persistent Atrial Fibrillation
Tilz, R. R., Rillig, A., Thum, A.-M., Arya, A., Wohlmuth, P., Metzner, A., Mathew, S., Yoshiga, Y., Wißner, E., Kück, K., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.04.060 · Cited by 468 · see citing works
O'Neill, M. D., Wright, M., Knecht, S., Jais, P., Hocini, M., Takahashi, Y., Jonsson, A., Sacher, F., Matsuo, S., Lim, K. T., et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp063 · Cited by 333 · see citing works
Self-citationElayi, C. S., Verma, A., Biase, L. D., Ching, C. K., Patel, D., Barrett, C. D., Martin, D. O., Bai, R., Fahmy, T. S. E., Khaykin, Y., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.09.016 · Cited by 321 · see citing works
Left atrial linear lesions are required for successful treatment of persistent atrial fibrillation
Knecht, S., Hocini, M., Wright, M. J., Lellouche, N., O'Neill, M. D., Matsuo, S., Nault, I., Chauhan, V. S., Makati, K. J., Bevilacqua, M., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn302 · Cited by 259 · see citing works
Self-citationTakahashi, Y., O'Neill, M. D., Hocini, M., Dubois, R., Matsuo, S., Knecht, S., Mahapatra, S., Lim, K., Jaı̈s, P., Jonsson, A., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.10.056 · Cited by 239 · see citing works
Self-citationNoninvasive Panoramic Mapping of Human Atrial Fibrillation Mechanisms: A Feasibility Report
Haı̈ssaguerre, M., Hocini, M., Shah, A. J., Derval, N., Sacher, F., Jaı̈s, P., & Dubois, R. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12075 · Cited by 220 · see citing works
Self-citationRostock, T., Salukhe, T. V., Steven, D., Drewitz, I., Hoffmann, B. A., Bock, K., Servatius, H., Müllerleile, K., Sultan, A., Gosau, N., et al. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.04.012 · Cited by 209 · see citing works
Self-citationElayi, C. S., Biase, L. D., Barrett, C. D., et al. (2010) · Heart Rhythm · doi:10.1016/j.hrthm.2010.01.038 · Cited by 146 · see citing works
Hocini, M., Nault, I., Wright, M. J., Veenhuyzen, G. D., Narayan, S. M., Jaı̈s, P., Lim, K., Knecht, S., Matsuo, S., Forclaz, A., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.09.060 · Cited by 131 · see citing works
Self-citationOral, H., Chugh, A., Good, E. D., Crawford, T. C., SARRAZIN, J., Kühne, M., Chalfoun, N. T., Wells, D., Boonyapisit, W., Gadeela, N., et al. (2008) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.107.748780 · Cited by 90 · see citing works
Estner, H., Hessling, G., Ndrepepa, G., et al. (2007) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2007.08.053 · Cited by 76 · see citing works
Heist, E. K., Chalhoub, F. M., Barrett, C. D., Danik, S. B., Ruskin, J. N., & MANSOUR, M. C. (2012) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2012.04.028 · Cited by 67 · see citing works
Circumferential Ablation With Pulmonary Vein Isolation in Permanent Atrial Fibrillation
Cheema, A., Dong, J., Dalal, D., et al. (2007) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.12.073 · Cited by 66 · see citing works
Importance of Sinus Rhythm as Endpoint of Persistent Atrial Fibrillation Ablation
Ammar, S., Hessling, G., Reents, T., PAULIK, M., Fichtner, S., Schön, P., Dillier, R., Kathan, S., Jilek, C., Kolb, C., et al. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12045 · Cited by 51 · see citing works
PARK, Y. M., Choi, J., Lim, H. E., Park, S. W., & Kim, Y. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2012.02370.x · Cited by 47 · see citing works
Flagged first, then by citations
Research works printed but not linked: 7
- Calkins H, Kuck KH,Cappato R, Brugada J, Camm AJ, Chen SA, Crijns HJ, Damiano RJ Jr, Davies DW, DiMarco J, Edgerton J, Ellenbogen K, Ezekowitz MD, Haines DE, Haissaguerre M, Hindricks G, Iesaka Y, Jackman W, Jalife J, Jais P, Kalman J, Keane D, Kim YH, Kirchhof P, Klein G, Kottkamp H, Kumagai K, Lindsay BD, Mansour M, Marchlinski FE, McCarthy PM, Mont JL, Morady F, Nademanee K, Nakagawa H, Natale A, Nattel S, Packer DL, Pappone C, Prystowsky E, Raviele A, Reddy V, Ruskin JN, Shemin RJ, Tsao HM, Wilber D. HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation. Europace. 2012;14:528-606.
- Fuster V, Rydén LE, Asinger RW, Cannom DS, Crijns HJ, Frye RL, Halperin JL, Kay GN, Klein WW, Lévy S, McNamara RL, PrystowskyEN, Wann LS, Wyse DG. ACC/AHA/ESC Guidelines for the Management of Patients with Atrial Fibrillation. Circulation. 2001;104:2118- 2150.
- Haïssaguerre M, Sanders P, Hocini M, Takahashi Y, Rotter M, Sacher F, Rostock T, Hsu LF, Bordachar P, Reuter S, Roudaut R, Clémenty J, Jaïs P. Catheter ablation of long- lasting persistent atrial fibrillation: critical structures for termination. J Cardiovasc Electrophysiol. 2005;16:1125-1137.
- Haïssaguerre M, Hocini M, Sanders P, Sacher F, Rotter M, Takahashi Y, Rostock T, Hsu LF, Bordachar P, Reuter S, Roudaut R, Clémenty J, Jaïs P. Catheter ablation of long-lasting persistent atrial fibrillation: clinical outcome and mechanisms of subsequent arrhythmias. J Cardiovasc Electrophysiol. 2005;16:1138-1147.
- O'Neill MD, Wright M, Knecht S, Jaïs P, Hocini M, Takahashi Y, Jönsson A, Sacher F, Matsuo S, Lim KT, Arantes L, Derval N, Lellouche N, Nault I, Bordachar P, Clémenty J, Haïssaguerre M. Long-term follow-up of persistent atrial fibrillation ablation using termination as a procedural endpoint. Eur Heart J. 2009;30:1105-1112.
- Hocini M, Nault I, Wright M, Veenhuyzen G, Narayan SM, Jaïs P, Lim KT, Knecht S, Matsuo S, Forclaz A, Miyazaki S, Jadidi A, O'Neill MD, Sacher F, Clémenty J, Haïssaguerre M. Disparate evolution of right and left atrial rate during ablation of long- lasting persistent atrial fibrillation. J Am Coll Cardiol. 2010;55:1007-1016.
- Dallas, TX 75231 is published by the American Heart Association, 7272 Greenville Avenue, Circulation: Arrhythmia and Electrophysiology published online December 20, 2014; Circ Arrhythm Electrophysiol. http://circep.ahajournals.org/content/early/2014/12/20/CIRCEP.114.001943 World Wide Web at: The online version of this article, along with updated information and services, is located on the http://circep.ahajournals.org/content/suppl/2014/12/20/CIRCEP.114.001943.DC1.html Data Supplement (unedited) at: http://circep.ahajournals.org//subscriptions/ is online at: Circulation: Arrhythmia and Electrophysiology Information about subscribing to Subscriptions: http://www.lww.com/reprints Information about reprints can be found online at: Reprints: document. Permissions and Rights Question and Answer information about this process is available in the requested is located, click Request Permissions in the middle column of the Web page under Services. Further
Cited by
Sorted by citations
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418 · see citing works
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezw313 · Cited by 1,403 · see citing works
Pulmonary Vein Isolation Versus Defragmentation
Vogler, J., Willems, S., Sultan, A., Schreiber, D., Lüker, J., Servatius, H., Schäffer, B., Moser, J., Hoffmann, B. A., & Steven, D. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.09.088 · Cited by 349 · see citing works
Schreiber, D., Rostock, T., Fröhlich, M., Sultan, A., Servatius, H., Hoffmann, B. A., Lüker, J., Berner, I., Schäffer, B., Wegscheider, K., et al. (2015) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.114.001672 · Cited by 175 · see citing works
Self-citation
- Authors
- Scherr, D., Khairy, P., Miyazaki, S., Aurillac-Lavignolle, V., Pascale, P., Wilton, S. B., Ramoul, K., Komatsu, Y., Roten, L., Jadidi, A., Linton, N., Pedersen, M., Daly, M., O’Neill, M., Knecht, S., Weerasooriya, R., Rostock, T., Manninger, M., Cochet, H., Shah, A. J., Yeim, S., Denis, A., Derval, N., Hocini, M., Sacher, F., Haissaguerre, M., & Jais, P.
- Affiliations
- Hôpital Cardiologique du Haut-Lévêque (FR)
- From the Hôpital Cardiologique du Haut Lévêque, Université Victor-Segalen Bordeaux, Pessac, France (D.S., P.K., S.M., V.A.-L., P.P., S.B.W., K.R., Y.K., L.R., A.J., N.L., M.P., M.D., M.O’N., S.K., R.W., T.R., H.C., A.J.S., S.Y., A.D., N.D., M.H., F.S., M.H., P.J.); and Division of Cardiology, Department of Medicine, Medical University of Graz, Austria (D.S., M.M.).
- ORCID
- Venue
- Circulation Arrhythmia and Electrophysiology
- Published
- 2015-02
- Volume
- 8
- Issue
- 1
- Pages
- 18-24
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2106377001
- Cited by
- 303
- References
- 30
- Citations by year
- 2026: 9 · 2025: 10 · 2024: 25 · 2023: 23 · 2022: 20 · 2021: 20 · 2020: 33 · 2019: 31 · 2018: 33 · 2017: 43 · 2016: 34 · 2015: 20
- FWCI
- 22.22
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Circulation Arrhythmia and Electrophysiology (publishedVersion)
- PubMed (publishedVersion)
- UWA Profiles and Research Repository (UWA) (submittedVersion)
- Bern Open Repository and Information System (University of Bern) (submittedVersion, other-oa)
- IRIS (submittedVersion)
- SERVAL (Université de Lausanne) (submittedVersion)
- Open Access CRIS of the University of Bern
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- persistent atrial fibrillation, catheter ablation, pulmonary vein isolation, linear ablation, arrhythmia-free survival, repeat ablation, left atrial diameter, structural heart disease, atrial tachycardia, long-term outcomes, procedural endpoint, antiarrhythmic drugs, sinus rhythm
- MeSH terms
- Aged, Anti-Arrhythmia Agents, Atrial Fibrillation, Female, Humans, Male, Middle Aged, Predictive Value of Tests, Prospective Studies, Pulmonary Veins, Recurrence, Reoperation, Risk Factors, Tachycardia, Supraventricular, Time Factors, Proportional Hazards Models, Treatment Outcome, Catheter Ablation, Disease-Free Survival, Electrophysiologic Techniques, Cardiac, Kaplan-Meier Estimate
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review