Is There Still a Role for Complex Fractionated Atrial Electrogram Ablation in Addition to Pulmonary Vein Isolation in Patients With Paroxysmal and Persistent Atrial Fibrillation?: Meta-Analysis of 1415 Patients
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Background—: Ablation of complex fractionated atrial electrograms (CFAEs) has been proposed as a strategy to improve outcomes in atrial fibrillation (AF) catheter ablation, but the use of this technique remains contentious. We aimed to assess the impact of CFAE ablation in addition to pulmonary vein isolation (PVI) in patients undergoing ablation for AF. Methods and Results—: We performed a random effects meta-analysis of studies comparing PVI versus PVI+CFAE ablation. The outcomes of freedom from AF/atrial tachycardia after 1 or several ablation procedures and acute procedural–related complications were assessed. Studies were searched on MEDLINE, EMBASE, COCHRANE, and clinicaltrials.gov , and sensitivity analyses were performed. Thirteen studies including a total of 1415 patients were considered eligible. Additional ablation of CFAEs resulted in no improvement in mid-term procedural outcome or freedom from AF or atrial tachycardia (odds ratio [OR], 0.80; 95% confidence interval [CI], 0.58–1.10; P =0.17). Sensitivity analysis of 398 paroxysmal AF ablation procedures showed no incremental benefit of CFAE ablation (OR, 0.80; 95% CI, 0.46–1.38; P =0.42). PVI+CFAE ablation versus PVI alone did not improve the overall rate of freedom from AF or atrial tachycardia in patients with persistent AF (OR, 1.01; 95% CI, 0.63–1.64; P =0.96) or longstanding persistent AF (OR, 0.84; 95% CI, 0.24–2.96; P =0.79). There was no increase in procedural-related adverse events (OR, 1.06; 95% CI, 0.41–2.75; P =0.91). Conclusions—: Despite the apparent safety of this technique, CFAE ablation did not improve freedom from AF/atrial tachycardia in patients with paroxysmal or persistent AF. The role of CFAE ablation in addition to PVI should be questioned and other alternatives assessed to improve the outcome of AF ablation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lang, R. M., Bierig, M., Devereux, R. B., Flachskampf, F. A., Foster, E., Pellikka, P. A., Picard, M. H., Roman, M. J., Seward, J., Shanewise, J. S., et al. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.10.005 · Cited by 11,318
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Approaches to catheter ablation for persistent atrial fibrillation
Verma, A., Jiang, C.-Y., Betts, T. R., Chen, J., Deisenhofer, I., Mantovan, R., Macle, L., Morillo, C. A., Haverkamp, W., Weerasooriya, R., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1408288 · Cited by 2,339
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000040 · Cited by 2,056
Pathak, R. K., Middeldorp, M. E., Lau, D. H., Mehta, A. B., Mahajan, R., Twomey, D., Alasady, M., Hanley, L., Antic, N. A., McEvoy, R. D., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.09.028 · Cited by 949
Mont, L., Bisbal, F., Hernández-Madrid, A., Pérez-Castellano, N., Viñolas, X., Arenal, A., Arribas, F., Fernández-Lozano, I., Bodegas, A., Cobos, A., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht457 · Cited by 394 · cited 1×
“but almost 40% of patients presented with AF or AT relapses in the first 12 months.(27) In this trial, CFAE or linear ablation”
BackgroundScherr, D., Khairy, P., Miyazaki, S., Aurillac-Lavignolle, V., Pascale, P., Wilton, S. B., Ramoul, K., Komatsu, Y., Roten, L., Jadidi, A., et al. (2015) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.114.001943 · Cited by 303 · cited 1×
“Data also suggest that termination of persistent AF during catheter ablation is a predictor of long-term success.(34) It would therefore be expected that CFAE ablation in addition to PVI might result in better long-term outcomes.”
BackgroundRanolazine enhances the efficacy of amiodarone for conversion of recent-onset atrial fibrillation
Koskinas, K. C., Fragakis, N., Katritsis, D., Skeberis, V., & Vassilikos, V. (2014) · Europace · doi:10.1093/europace/eut407 · Cited by 72
Cited by
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · Europace · doi:10.1093/europace/euw295 · Cited by 6,439
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezw313 · Cited by 1,403
Tzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Sepehri Shamloo, A., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Europace · doi:10.1093/europace/euae043 · Cited by 634
Tzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Shamloo, A. S., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.03.017 · Cited by 298
Metadata
- Authors
- Providência, R., Lambiase, P. D., Srinivasan, N., Ganesh Babu, G., Bronis, K., Ahsan, S., Khan, F. Z., Chow, A. W., Rowland, E., Lowe, M., & Segal, O. R.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2015-10
- Volume
- 8
- Issue
- 5
- Pages
- 1017-1029
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2552752550
- Cited by
- 92
- References
- 8
- FWCI
- 10.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.