Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 160

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Redefining the Blanking Period After Catheter Ablation for Paroxysmal Atrial Fibrillation: Insights From the ADVICE (Adenosine Following Pulmonary Vein Isolation to Target Dormant Conduction Elimination) Trial

Willems, Stephan, Khairy, Paul, Andrade, Jason G., Hoffmann, Boris A., Levesque, Sylvie, Verma, Atul, Weerasooriya, Rukshen, Novak, Paul, Arentz, Thomas, Deisenhofer, Isabel, Rostock, Thomas, Steven, Daniel, Rivard, Lena, Guerra, Peter G., Dyrda, Katia, Mondesert, Blandine, Dubuc, Marc, Thibault, Bernard, Talajic, Mario, Roy, Denis, Nattel, Stanley, Macle, Laurent · 2016 · Circulation: Arrhythmia and Electrophysiology

Abstract

Background—: Early recurrences (ERs) of atrial tachyarrhythmia are common after catheter ablation of atrial fibrillation. A 3-month blanking period is recommended by current guidelines. This study sought to investigate the significance of ER during the first 3 months post ablation in predicting late recurrences and determine whether it varies according to timing. Methods and Results—: A total of 401 patients with paroxysmal atrial fibrillation undergoing pulmonary vein isolation were followed for 12 months with transtelephonic monitoring in the ADVICE (Adenosine Following Pulmonary Vein Isolation to Target Dormant Conduction Elimination) trial. Patients with atrial tachyarrhythmia ≥30 s within the 3-month blanking period were stratified according to the timing of ER. A total of 179 patients (44.6%) experienced their last episode of ER during the first (n=53), second (n=44), or third (n=82) month of the 3-month blanking period. One-year freedom from symptomatic atrial tachyarrhythmia was 77.2% in patients without ER compared with 62.6%, 36.4%, and 7.8% in patients with ER 1, 2, and 3 months post ablation, respectively ( P <0.0001). Receiver operating curve analyses revealed a strong correlation between the timing of ER and late recurrence (area under the curve 0.82, P <0.0001). Corresponding hazard ratios for ER during the first, second, and third months were 1.84, 4.45, and 9.64, respectively. Conclusions—: This study validates the use of a blanking period after catheter ablation for paroxysmal atrial fibrillation but calls into question the 90-day cut-off value. In particular, >90% of patients with ER during the third month post ablation experience late recurrence by 1 year. However, pending further study, repeat ablation before 90 days cannot be routinely advocated. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT01058980.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.115.003909

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 160

Metadata

Authors
Willems, S., Khairy, P., Andrade, J. G., Hoffmann, B. A., Levesque, S., Verma, A., Weerasooriya, R., Novak, P., Arentz, T., Deisenhofer, I., Rostock, T., Steven, D., Rivard, L., Guerra, P. G., Dyrda, K., Mondesert, B., Dubuc, M., Thibault, B., Talajic, M., Roy, D., Nattel, S., & Macle, L.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2016-08
Volume
9
Issue
8
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W2548666065
Cited by
160
References
3
FWCI
8.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.