CoChat

Left Atrial Size and Function in Hypertrophic Cardiomyopathy Patients and Risk of New-Onset Atrial Fibrillation

Debonnaire, Philippe, Joyce, Emer, Hiemstra, Yasmine, Mertens, Bart J., Atsma, Douwe E., Schalij, Martin J., Bax, Jeroen J., Delgado, Victoria, Marsan, Nina Ajmone · 2017 · Circulation: Arrhythmia and Electrophysiology
Cited by 192

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background—: The value of left atrial (LA) diameter, volume, and strain to risk stratify hypertrophic cardiomyopathy patients for new-onset atrial fibrillation (AF) was explored. Methods and Results—: A total of 242 hypertrophic cardiomyopathy patients without AF history were evaluated by (speckle-tracking) echocardiography. During mean follow-up of 4.8±3.7 years, 41 patients (17%) developed new-onset AF. Multivariable analysis showed LA volume (≥37 mL/m 2 ; hazard ratio, 2.68; 95% confidence interval, 1.30–5.54; P =0.008) and LA strain (≤23.4%; hazard ratio, 3.22; 95% confidence interval, 1.50–6.88; P =0.003), but not LA diameter (≥45 mm; hazard ratio, 1.67; 95% confidence interval, 0.84–3.32; P =0.145), as independent AF correlates. Importantly, 59% (n=24) of AF events occurred despite a baseline LA diameter <45 mm, observed in 185 patients. In this patient subset, LA strain (area under the curve 0.73) and LA volume (area under the curve 0.83) showed good predictive value for new-onset AF. Furthermore, patients with LA volume <37 versus ≥37 mL/m 2 and LA strain >23.4% versus ≤23.4% had superior 5-year AF-free survival of 93% versus 80% ( P =0.003) and 98% versus 74% ( P =0.002), respectively. Importantly, LA volume <37 mL/m 2 and strain >23.4% yielded high negative predictive value (93% and 98%, respectively) for new-onset AF. Likelihood ratio test indicated incremental value of LA volume assessment ( P =0.011) on top of LA diameter to predict new-onset AF in hypertrophic cardiomyopathy patients with LA diameter <45 mm, which tended to increase further by addition of LA strain ( P =0.126). Conclusions—: LA diameter, volume, and strain all relate to new-onset AF in hypertrophic cardiomyopathy patients. In patients with normal LA size, however, both LA volume and strain further refine risk stratification for new-onset AF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.116.004052

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • 2014 ESC Guidelines on diagnosis and management of hypertrophic cardiomyopathy

    Authors/Task Force members, Elliott, P. M., Anastasakis, A., Borger, M. A., Borggrefe, M., Cecchi, F., Charron, P., Hagege, A. A., Lafont, A., Limongelli, G., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu284 · Cited by 4,332 · cited 9×

    “Similar statistical analysis was performed, restricting the study population to patients with LA diameter <45 mm, generally regarded as being at low risk for newonset AF.(2) SPSS version 20.”
    BackgroundMethodInfluentialSelf-citation

Cited by

See all 192

Metadata

Authors
Debonnaire, P., Joyce, E., Hiemstra, Y., Mertens, B. J., Atsma, D. E., Schalij, M. J., Bax, J. J., Delgado, V., & Marsan, N. A.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2017-02
Volume
10
Issue
2
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W2587575268
Cited by
192
References
1
FWCI
7.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.