Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 162

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Diagnosis-to-Ablation Time and Recurrence of Atrial Fibrillation Following Catheter Ablation: A Systematic Review and Meta-Analysis of Observational Studies

Open access
Chew, Derek S., Black-Maier, Eric, Loring, Zak, Noseworthy, Peter A., Packer, Douglas L., Exner, Derek V., Mark, Daniel B., Piccini, Jonathan P. · 2020 · Circulation: Arrhythmia and Electrophysiology

Abstract

Background: The optimal timing of catheter ablation for atrial fibrillation (AF) in reference to the time of diagnosis is unknown. We sought to assess the impact of the duration between first diagnosis of AF and ablation, or diagnosis-to-ablation time (DAT), on AF recurrence following catheter ablation. Methods: We conducted a systematic electronic search for observational studies reporting the outcomes associated with catheter ablation for atrial fibrillation stratified by diagnosis-to-ablation time. The primary meta-analysis using a random effects model assessed AF recurrence stratified by DAT ≤1 year versus >1 year. A secondary analysis assessed outcomes stratified by DAT ≤3 years versus >3 years. Results: Of the 632 screened studies, 6 studies met inclusion criteria for a total of 4950 participants undergoing AF ablation for symptomatic AF. A shorter DAT ≤1 year was associated with a lower relative risk of AF recurrence compared with DAT >1 year (relative risk, 0.73 [95% CI, 0.65–0.82]; P <0.001). Heterogeneity was moderate (I 2 =51%). When excluding the one study consisting of only patients with persistent AF, the heterogeneity improved substantially (I 2 =0%, Cochran’s Q P =0.55) with a similar estimate of effect (relative risk, 0.78 [95% CI, 0.71–0.85]; P <0.001). Conclusions: Shorter duration between time of first AF diagnosis and AF ablation is associated with an increased likelihood of ablation procedural success. Additional study is required to confirm these results and to explore implementation of earlier catheter AF ablation and patient outcomes within the current AF care pathway. Visual Overview: A visual overview is available for this article.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.119.008128

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 162

Metadata

Authors
Chew, D. S., Black-Maier, E., Loring, Z., Noseworthy, P. A., Packer, D. L., Exner, D. V., Mark, D. B., & Piccini, J. P.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2020-04
Volume
13
Issue
4
Pages
e008128-e008128
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W3012123000
Cited by
162
References
3
FWCI
10.61
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnosis-to-Ablation Time and Recurrence of Atrial Fibrillation Following Catheter Ablation: A Systematic Review and Meta-Analysis of Observational Studies. https://app.cochat.ai/papers/10.1161/circep.119.008128
The paper
Chew, D. S., Black-Maier, E., Loring, Z., Noseworthy, P. A., Packer, D. L., Exner, D. V., Mark, D. B., & Piccini, J. P. (2020). Diagnosis-to-Ablation Time and Recurrence of Atrial Fibrillation Following Catheter Ablation: A Systematic Review and Meta-Analysis of Observational Studies. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.119.008128

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.