Comprehensive Analysis of Protein Modifications by Top-Down Mass Spectrometry
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Mass spectrometry (MS)-based proteomics is playing an increasingly important role in cardiovascular research. Proteomics includes identification and quantification of proteins and the characterization of protein modifications, such as posttranslational modifications and sequence variants. The conventional bottom-up approach, involving proteolytic digestion of proteins into small peptides before MS analysis, is routinely used for protein identification and quantification with high throughput and automation. Nevertheless, it has limitations in the analysis of protein modifications, mainly because of the partial sequence coverage and loss of connections among modifications on disparate portions of a protein. An alternative approach, top-down MS, has emerged as a powerful tool for the analysis of protein modifications. The top-down approach analyzes whole proteins directly, providing a "bird's-eye" view of all existing modifications. Subsequently, each modified protein form can be isolated and fragmented in the mass spectrometer to locate the modification site. The incorporation of the nonergodic dissociation methods, such as electron-capture dissociation (ECD), greatly enhances the top-down capabilities. ECD is especially useful for mapping labile posttranslational modifications that are well preserved during the ECD fragmentation process. Top-down MS with ECD has been successfully applied to cardiovascular research, with the unique advantages in unraveling the molecular complexity, quantifying modified protein forms, complete mapping of modifications with full-sequence coverage, discovering unexpected modifications, identifying and quantifying positional isomers, and determining the order of multiple modifications. Nevertheless, top-down MS still needs to overcome some technical challenges to realize its full potential. Herein, we reviewed the advantages and challenges of the top-down method, with a focus on its application in cardiovascular research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370
Mass spectrometry–based proteomics turns quantitative
Ong, S.-E., & Mann, M. (2005) · Nature Chemical Biology · doi:10.1038/nchembio736 · Cited by 1,572
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
Automated reduction and interpretation of
Horn, D. M., Zubarev, R. A., & McLafferty, F. W. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00157-9 · Cited by 507
Decoding protein modifications using top-down mass spectrometry
Siuti, N., & Kelleher, N. L. (2007) · Nature Methods · doi:10.1038/nmeth1097 · Cited by 503
Extending Top-Down Mass Spectrometry to Proteins with Masses Greater Than 200 Kilodaltons
Han, X., Jin, M., Breuker, K., & McLafferty, F. W. (2006) · Science · doi:10.1126/science.1128868 · Cited by 328
Tran, J. C., & Doucette, A. A. (2008) · Analytical Chemistry · doi:10.1021/ac702197w · Cited by 206
Processing Complex Mixtures of Intact Proteins for Direct Analysis by Mass Spectrometry
Meng, F., Cargile, B. J., Patrie, S. M., Johnson, J. R., McLoughlin, S. M., & Kelleher, N. L. (2002) · Analytical Chemistry · doi:10.1021/ac020049i · Cited by 183
Ge, Y., Rybakova, I. N., Xu, Q., & Moss, R. L. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0813369106 · Cited by 154
Self-citation
Cited by
Beyond mass spectrometry, the next step in proteomics
Timp, W., & Timp, G. (2020) · Science Advances · doi:10.1126/sciadv.aax8978 · Cited by 302
Mass Spectrometry-Based Detection and Assignment of Protein Posttranslational Modifications
Doll, S., & Burlingame, A. L. (2015) · ACS Chemical Biology · doi:10.1021/cb500904b · Cited by 261
Top‐down proteomics in health and disease: Challenges and opportunities
Gregorich, Z. R., & Ge, Y. (2014) · PROTEOMICS · doi:10.1002/pmic.201300432 · Cited by 217
“Top-down MS can provide relative quantification of modified versus unmodified proteoforms (or proteoforms with minor sequence variations) due to the fact that the addition of modifying groups to intact proteins has minimal influence on the overall physicochemical properties of the proteins [15]; and, thus, the effect…”
BackgroundSelf-citationTop-Down Proteomics: Ready for Prime Time?
Chen, B., Brown, K. A., Lin, Z., & Ge, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04747 · Cited by 210
Self-citationTop-down proteomics: challenges, innovations, and applications in basic and clinical research
Brown, K. A., Melby, J. A., Roberts, D. S., & Ge, Y. (2020) · Expert Review of Proteomics · doi:10.1080/14789450.2020.1855982 · Cited by 152
Self-citation
Metadata
- Authors
- Zhang, H., & Ge, Y.
- Venue
- Circulation: Cardiovascular Genetics
- Published
- 2011-12
- Volume
- 4
- Issue
- 6
- Pages
- 711-711
- ISSN
- 1942-325X (ISSN-L)
- 1942-3268
- OpenAlex
- W2152791704
- Cited by
- 148
- References
- 11
- FWCI
- 5.61
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comprehensive Analysis of Protein Modifications by Top-Down Mass Spectrometry. https://app.cochat.ai/papers/10.1161/circgenetics.110.957829
- The paper
- Zhang, H., & Ge, Y. (2011). Comprehensive Analysis of Protein Modifications by Top-Down Mass Spectrometry. Circulation: Cardiovascular Genetics. https://doi.org/10.1161/circgenetics.110.957829
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.