Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 187

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Heart Failure Care in the Outpatient Cardiology Practice Setting: Findings From IMPROVE HF

Fonarow, Gregg C., Yancy, Clyde W., Albert, Nancy M., Curtis, Anne B., Stough, Wendy Gattis, Gheorghiade, Mihai, Heywood, J. Thomas, McBride, Mark L., Mehra, Mandeep R., O'Connor, Christopher M., Reynolds, Dwight, Walsh, Mary Norine · 2008 · Circulation: Heart Failure

Abstract

Background— Few data exist regarding contemporary care patterns for heart failure (HF) in the outpatient setting. IMPROVE HF is a prospective cohort study designed to characterize current management of patients with chronic HF and ejection fraction ≤35% in a national registry of 167 US outpatient cardiology practices. Methods and Results— Baseline patient characteristics and data on care of 15381 patients with diagnosed HF or prior myocardial infarction and left ventricular dysfunction were collected by chart abstraction. To quantify use of therapies, 7 individual metrics (use of angiotensin-converting enzyme inhibitor/angiotensin receptor blocker, β-blocker, aldosterone antagonist, anticoagulation, implantable cardioverter defibrillator, cardiac resynchronization therapy, and HF education) and composite metrics were assessed. Care metrics include only patients documented to be eligible and without contraindications or intolerance. Among practices, 69% were nonteaching. Patients were 71% male, with a median age of 70 years, and a median ejection fraction of 25%. Use of angiotensin-converting enzyme inhibitor/angiotensin receptor blocker (80%) and β-blocker (86%) was relatively high in eligible patients in the outpatient cardiology setting; other metrics, such as aldosterone antagonist (36%), device therapy (implantable cardioverter defibrillator/cardiac resynchronization therapy with defibrillator, 51%; cardiac resynchronization therapy, 39%), and education (61%), showed lower rates of use. A median 27% of patients received all HF therapies for which they were potentially eligible on the basis of chart documentation. Use of guideline-recommended therapies by practices varied widely. Conclusions— These data are among the first to assess treatment in the outpatient setting since the release of the latest national HF guidelines and to demonstrate substantial variation among cardiology practices in the documented therapies provided to HF patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circheartfailure.108.772228

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 187

Metadata

Authors
Fonarow, G. C., Yancy, C. W., Albert, N. M., Curtis, A. B., Stough, W. G., Gheorghiade, M., Heywood, J. T., McBride, M. L., Mehra, M. R., O'Connor, C. M., Reynolds, D., & Walsh, M. N.
Venue
Circulation: Heart Failure
Published
2008-07
Volume
1
Issue
2
Pages
98-106
ISSN
  • 1941-3289 (ISSN-L)
  • 1941-3297
OpenAlex
W2548066759
Cited by
187
References
8
FWCI
11.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Heart Failure Care in the Outpatient Cardiology Practice Setting: Findings From IMPROVE HF. https://app.cochat.ai/papers/10.1161/circheartfailure.108.772228
The paper
Fonarow, G. C., Yancy, C. W., Albert, N. M., Curtis, A. B., Stough, W. G., Gheorghiade, M., Heywood, J. T., McBride, M. L., Mehra, M. R., O'Connor, C. M., Reynolds, D., & Walsh, M. N. (2008). Heart Failure Care in the Outpatient Cardiology Practice Setting: Findings From IMPROVE HF. Circulation: Heart Failure. https://doi.org/10.1161/circheartfailure.108.772228

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.