Outcomes in Advanced Heart Failure Patients With Left Ventricular Assist Devices for Destination Therapy
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Background—: The HeartMate II (HMII) destination therapy (DT) trial demonstrated significant improvements in outcomes in continuous-flow left ventricular assist devices compared with patients implanted with the pulsatile-flow HeartMate XVE. The primary hypothesis of the current study is that trial patients enrolled after the initial data cohort would have better clinical outcomes. Methods and Results—: Two hundred eighty-one patients who underwent HMII for DT from May 2007 to March 2009 (Mid Trial [MT] group) were compared with the initial 133 HMII patients from March 2005 to May 2007 (Early Trial [ET] group). Patient entry criteria were the same during the 2 time periods. Survival, adverse events, and quality of life were compared between the 2 groups. Baseline characteristics were similar between the groups. Compared with the ET group, patients in the MT group had reduced adverse event rates for bleeding requiring transfusions (1.66 versus 1.13 events per patient-year, P <0.001), sepsis (0.38 versus 0.27, P =0.025), device-related infections (0.47 versus 0.27, P <0.001), and hemorrhagic stroke (0.07 versus 0.03, P =0.01). Other event rates were similar between groups including ischemic stroke (0.06 versus 0.05 events per patient-year, P =0.57). Survival at 1 year in the MT group was 73% versus 68% in the ET group ( P =0.21). Additionally, there was a significant reduction in deaths caused by hemorrhagic stroke ( P =0.01). Quality of life improvements were significant in both the groups ( P <0.001). Conclusions—: The benefit of DT therapy with the HMII is confirmed in subsequent trial patients, with improved adverse event rates and a strong trend for improvements in survival. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT00121485.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2013 ACCF/AHA Guideline for the Management of Heart Failure
Yancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Drazner, M. H., Fonarow, G. C., Geraci, S. A., Horwich, T., Januzzi, J. L., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.05.019 · Cited by 12,536
Long-Term Use of a Left Ventricular Assist Device for End-Stage Heart Failure
Rose, E. A., Gelijns, A. C., Moskowitz, A. J., Heitjan, D. F., Stevenson, L. W., Dembitsky, W., Long, J. W., Ascheim, D. D., Tierney, A. R., Levitan, R. G., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa012175 · Cited by 3,977
2005 WRITING COMMITTEE MEMBERS, Hunt, S. A., Abraham, W. T., Chin, M. H., Feldman, A. M., Francis, G. S., Ganiats, T. G., Jessup, M., Konstam, M. A., Mancini, D. M., et al. (2009) · Circulation · doi:10.1161/circulationaha.109.192065 · Cited by 3,720
Advanced heart failure treated with continuous-flow left ventricular assist device
Slaughter, M. S., Rogers, J. G., Milano, C. A., Russell, S. D., Conte, J. V., Feldman, D., Sun, B., Tatooles, A. J., Delgado, R. M., Long, J. W., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0909938 · Cited by 3,063
Self-citationThe Seattle Heart Failure Model: Prediction of Survival in Heart Failure
Levy, W. C., Mozaffarian, D., Linker, D. T., Sutradhar, S. C., Anker, S. D., Cropp, A. B., Anand, I., Maggioni, A., Burton, P., Sullivan, M. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.584102 · Cited by 2,021
Use of a Continuous-Flow Device in Patients Awaiting Heart Transplantation
Miller, L. W., Pagani, F. D., Russell, S. D., John, R., Boyle, A. J., Aaronson, K. D., Conte, J. V., Naka, Y., Mancini, D., Delgado, R. M., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067758 · Cited by 1,733
Self-citationClinical management of continuous-flow left ventricular assist devices in advanced heart failure
Slaughter, M. S., Pagani, F. D., Rogers, J. G., Miller, L. W., Sun, B., Russell, S. D., Starling, R. C., Chen, L., Boyle, A. J., Chillcott, S., et al. (2010) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2010.01.011 · Cited by 874
Self-citationExtended Mechanical Circulatory Support With a Continuous-Flow Rotary Left Ventricular Assist Device
Pagani, F. D., Miller, L. W., Russell, S. D., Aaronson, K. D., John, R., Boyle, A. J., Conte, J. V., Bogaev, R. C., MacGillivray, T. E., Naka, Y., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.03.055 · Cited by 869
Self-citationLietz, K., Long, J. W., Kfoury, A. G., Slaughter, M. S., Silver, M. A., Milano, C. A., Rogers, J. G., Naka, Y., Mancini, D., & Miller, L. W. (2007) · Circulation · doi:10.1161/circulationaha.107.691972 · Cited by 755
Self-citationRogers, J. G., Aaronson, K. D., Boyle, A. J., Russell, S. D., Milano, C. A., Pagani, F. D., Edwards, B. S., Park, S., John, R., Conte, J. V., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.12.052 · Cited by 586
Self-citationStarling, R. C., Naka, Y., Boyle, A. J., Gonzalez-Stawinski, G., John, R., Jorde, U., Russell, S. D., Conte, J. V., Aaronson, K. D., McGee, E. C., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.10.062 · Cited by 452
Self-citationBoyle, A. J., Russell, S. D., Teuteberg, J. J., Slaughter, M. S., Moazami, N., Pagani, F. D., Frazier, O. H., Heatley, G., Farrar, D. J., & John, R. (2009) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2009.05.018 · Cited by 300
Self-citationTopkara, V. K., Kondareddy, S., Malik, F., Wang, I.-W., Mann, D. L., Ewald, G. A., & Moazami, N. (2010) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2010.04.093 · Cited by 281
Self-citationBoyle, A. J., Ascheim, D. D., Russo, M. J., Kormos, R. L., John, R., Naka, Y., Gelijns, A. C., Hong, K. N., & Teuteberg, J. J. (2011) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2010.10.016 · Cited by 272
Left Ventricular Assist Device Therapy in Patients With Restrictive and Hypertrophic Cardiomyopathy
Topilsky, Y., Pereira, N. L., Shah, D. K., Boilson, B., Schirger, J. A., Kushwaha, S. S., Joyce, L. D., & Park, S. J. (2011) · Circulation: Heart Failure · doi:10.1161/circheartfailure.110.959288 · Cited by 191
Self-citationAdamson, R. M., Stahovich, M. J., Chillcott, S. R., Baradarian, S., Chammas, J. H., Jaski, B. E., Hoagland, P. M., & Dembitsky, W. P. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.01.043 · Cited by 118
Self-citation
Cited by
Feldman, D., Pamboukian, S. V., Teuteberg, J. J., Birks, E., Lietz, K., Moore, S. A., Morgan, J. A., Arabia, F., Bauman, M. E., Buchholz, H. W., et al. (2013) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2012.09.013 · Cited by 1,368
Self-citationIntrapericardial Left Ventricular Assist Device for Advanced Heart Failure
Rogers, J. G., Pagani, F. D., Tatooles, A. J., Bhat, G., Slaughter, M. S., Birks, E. J., Boyce, S. W., Najjar, S. S., Jeevanandam, V., Anderson, A. S., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1602954 · Cited by 758
Self-citationBraunwald, E. (2013) · JACC: Heart Failure · doi:10.1016/j.jchf.2012.10.002 · Cited by 730
Najjar, S. S., Slaughter, M. S., Pagani, F. D., Starling, R. C., McGee, E. C., Eckman, P., Tatooles, A. J., Moazami, N., Kormos, R. L., Hathaway, D. R., et al. (2014) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2013.12.001 · Cited by 460
Self-citation2019 EACTS Expert Consensus on long-term mechanical circulatory support
Potapov, E. V., Antonides, C., Crespo-Leiro, M. G., Combes, A., Färber, G., Hannan, M. M., Kukucka, M., de Jonge, N., Loforte, A., Lund, L. H., et al. (2019) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezz098 · Cited by 399
Metadata
- Authors
- Park, S. J., Milano, C. A., Tatooles, A. J., Rogers, J. G., Adamson, R. M., Steidley, D. E., Ewald, G. A., Sundareswaran, K. S., Farrar, D. J., Slaughter, M. S., & for the HeartMate II Clinical Investigators†
- Venue
- Circulation: Heart Failure
- Published
- 2012-03
- Volume
- 5
- Issue
- 2
- Pages
- 241-248
- ISSN
- 1941-3289 (ISSN-L)
- 1941-3297
- OpenAlex
- W2115244114
- Cited by
- 341
- References
- 16
- FWCI
- 23.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.