The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Evaluation of the Left Atrial Appendage With Real-Time 3-Dimensional Transesophageal Echocardiography: Implications for Catheter-Based Left Atrial Appendage Closure
Abstract
Background—: Precise knowledge of left atrial appendage (LAA) orifice size is crucial for correct sizing of LAA closure devices. The aim of the present study was to determine the performance of real-time 3D transesophageal echocardiography (RT3DTEE) for LAA orifice size assessment, compared with 2D transesophageal echocardiography (2DTEE), and to investigate the impact of atrial fibrillation (AF) on LAA orifice size. Methods and Results—: One hundred thirty-seven patients (38 control subjects, 31 with paroxysmal AF, 38 with persistent AF and 30 with permanent AF) underwent 2DTEE and RT3DTEE. Both techniques were used to measure LAA orifice area. Clinically-indicated 64-slice computed tomography (CT) was used as reference technique in 46 patients. Two-dimensional TEE underestimated LAA orifice area, compared with RT3DTEE (1.99±0.94 cm 2 versus 3.05±1.27 cm 2 ; P <0.001). RT3DTEE showed higher correlation with CT for the assessment of LAA orifice area, compared with 2DTEE ( r =0.92; 95% confidence interval, 0.85 to 0.95, versus r =0.72; 95% confidence interval, 0.54 to 0.83, respectively). At Bland–Altman analysis, RT3DTEE and 2DTEE underestimated LAA orifice area, compared with CT. However, RT3DTEE showed smaller bias (0.07 cm 2 versus 0.72 cm 2 ) and narrower limits of agreement (−0.71 to 0.85 cm 2 versus −0.58 to 2.02 cm 2 ) with CT, compared with 2DTEE. Among AF patients, a progressive increase in RT3DTEE-derived LAA orifice area was observed with increasing frequency of AF ( P <0.001). At multivariate analysis, AF and left atrial volume index ( P <0.001 for both) were independently associated with RT3DTEE-derived LAA orifice area. Conclusions—: RT3DTEE is more accurate than 2DTEE for the assessment of LAA orifice size. A progressive increase in LAA orifice area is observed with increasing frequency of AF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lang, R. M., Bierig, M., Devereux, R. B., Flachskampf, F. A., Foster, E., Pellikka, P. A., Picard, M. H., Roman, M. J., Seward, J., Shanewise, J. S., et al. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.10.005 · Cited by 11,318
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Appendage obliteration to reduce stroke in cardiac surgical patients with atrial fibrillation
Blackshear, J. L., & Odell, J. A. (1996) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(95)00887-x · Cited by 1,686 · cited 1×
“Discussion The results of the present study can be summarized as follows: (1) RT3DTEE-derived measurements of LAA orifice area are closely related with CT measurements, which is the gold standard for LAA anatomic evaluation; (2) 2DTEE significantly underestimates LAA dimension and orifice size, as compared with RT3DTE…”
Result
Cited by
Hahn, R. T., Abraham, T., Adams, M. S., Bruce, C. J., Glas, K. E., Lang, R. M., Reeves, S. T., Shanewise, J. S., Siu, S. C., Stewart, W., et al. (2013) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.07.009 · Cited by 1,351
The Left Atrial Appendage: Anatomy, Function, and Noninvasive Evaluation
Beigel, R., Wunderlich, N. C., Ho, S. Y., Arsanjani, R., & Siegel, R. J. (2014) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2014.08.009 · Cited by 516
Donal, E., Lip, G. Y. H., Galderisi, M., Goette, A., Shah, D., Marwan, M., Lederlin, M., Mondillo, S., Edvardsen, T., Sitges, M., et al. (2016) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jev354 · Cited by 341
EHRA/EAPCI expert consensus statement on catheter-based left atrial appendage occlusion
Meier, B., Blaauw, Y., Khattab, A. A., Lewalter, T., Sievert, H., Tondo, C., Glikson, M., ESC Scientific Document Group, Lip, G. Y. H., Lopez-Minguez, J., et al. (2014) · EP Europace · doi:10.1093/europace/euu174 · Cited by 324
Metadata
- Authors
- Nucifora, G., Faletra, F. F., Regoli, F., Pasotti, E., Pedrazzini, G., Moccetti, T., & Auricchio, A.
- Venue
- Circulation: Cardiovascular Imaging
- Published
- 2011-09
- Volume
- 4
- Issue
- 5
- Pages
- 514-523
- ISSN
- 1941-9651 (ISSN-L)
- 1942-0080
- OpenAlex
- W2547316355
- Cited by
- 204
- References
- 3
- FWCI
- 8.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of the Left Atrial Appendage With Real-Time 3-Dimensional Transesophageal Echocardiography: Implications for Catheter-Based Left Atrial Appendage Closure. https://app.cochat.ai/papers/10.1161/circimaging.111.963892
- The paper
- Nucifora, G., Faletra, F. F., Regoli, F., Pasotti, E., Pedrazzini, G., Moccetti, T., & Auricchio, A. (2011). Evaluation of the Left Atrial Appendage With Real-Time 3-Dimensional Transesophageal Echocardiography: Implications for Catheter-Based Left Atrial Appendage Closure. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.111.963892
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.