Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 204

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Evaluation of the Left Atrial Appendage With Real-Time 3-Dimensional Transesophageal Echocardiography: Implications for Catheter-Based Left Atrial Appendage Closure

Nucifora, Gaetano, Faletra, Francesco F., Regoli, François, Pasotti, Elena, Pedrazzini, Giovanni, Moccetti, Tiziano, Auricchio, Angelo·2011·Circulation: Cardiovascular Imaging

Abstract

Background—: Precise knowledge of left atrial appendage (LAA) orifice size is crucial for correct sizing of LAA closure devices. The aim of the present study was to determine the performance of real-time 3D transesophageal echocardiography (RT3DTEE) for LAA orifice size assessment, compared with 2D transesophageal echocardiography (2DTEE), and to investigate the impact of atrial fibrillation (AF) on LAA orifice size. Methods and Results—: One hundred thirty-seven patients (38 control subjects, 31 with paroxysmal AF, 38 with persistent AF and 30 with permanent AF) underwent 2DTEE and RT3DTEE. Both techniques were used to measure LAA orifice area. Clinically-indicated 64-slice computed tomography (CT) was used as reference technique in 46 patients. Two-dimensional TEE underestimated LAA orifice area, compared with RT3DTEE (1.99±0.94 cm 2 versus 3.05±1.27 cm 2 ; P <0.001). RT3DTEE showed higher correlation with CT for the assessment of LAA orifice area, compared with 2DTEE ( r =0.92; 95% confidence interval, 0.85 to 0.95, versus r =0.72; 95% confidence interval, 0.54 to 0.83, respectively). At Bland–Altman analysis, RT3DTEE and 2DTEE underestimated LAA orifice area, compared with CT. However, RT3DTEE showed smaller bias (0.07 cm 2 versus 0.72 cm 2 ) and narrower limits of agreement (−0.71 to 0.85 cm 2 versus −0.58 to 2.02 cm 2 ) with CT, compared with 2DTEE. Among AF patients, a progressive increase in RT3DTEE-derived LAA orifice area was observed with increasing frequency of AF ( P <0.001). At multivariate analysis, AF and left atrial volume index ( P <0.001 for both) were independently associated with RT3DTEE-derived LAA orifice area. Conclusions—: RT3DTEE is more accurate than 2DTEE for the assessment of LAA orifice size. A progressive increase in LAA orifice area is observed with increasing frequency of AF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circimaging.111.963892

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 204

Metadata

Authors
Nucifora, G., Faletra, F. F., Regoli, F., Pasotti, E., Pedrazzini, G., Moccetti, T., & Auricchio, A.
Venue
Circulation: Cardiovascular Imaging
Published
2011-09
Volume
4
Issue
5
Pages
514-523
ISSN
  • 1941-9651 (ISSN-L)
  • 1942-0080
OpenAlex
W2547316355
Cited by
204
References
3
FWCI
8.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of the Left Atrial Appendage With Real-Time 3-Dimensional Transesophageal Echocardiography: Implications for Catheter-Based Left Atrial Appendage Closure. https://app.cochat.ai/papers/10.1161/circimaging.111.963892
The paper
Nucifora, G., Faletra, F. F., Regoli, F., Pasotti, E., Pedrazzini, G., Moccetti, T., & Auricchio, A. (2011). Evaluation of the Left Atrial Appendage With Real-Time 3-Dimensional Transesophageal Echocardiography: Implications for Catheter-Based Left Atrial Appendage Closure. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.111.963892

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.