Morphological and Functional Adaptation of the Maternal Heart During Pregnancy

Savu, Oana, Jurcuţ, Ruxandra, Giuşcă, Sorin, van Mieghem, Tim, Gussi, Ilinca, Popescu, Bogdan A., Ginghină, Carmen, Rademakers, Frank, Deprest, Jan, Voigt, Jens-Uwe·2012·Circulation: Cardiovascular Imaging

Abstract

Background—: Pregnancy provides a unique model to study the adaptation of the heart in a physiological situation of transient load changes. The aim of this study was to assess the performance of the left ventricle (LV) in normal, uncomplicated pregnancies while considering the actual LV load and shape. Methods and Results—: Serial echocardiographic examinations were performed in 51 women in each pregnancy trimester and 3 to 6 months after delivery. Data from 10 nulliparous, age-matched women were used as the control. Conventional parameters of LV function (ejection fraction) as well as myocardial deformation (strain) were interpreted, taking into consideration maternal hemodynamics and LV shape. Cardiac output increased during pregnancy because of a higher stroke volume in early pregnancy and a late increase in heart rate, whereas total vascular resistance decreased. Progressive development of eccentric hypertrophy was observed, which subsequently recovered postpartum. Sphericity index decreased from the first to the third trimester (1.92±0.17 versus 1.71±0.17) and returned postpartum to values comparable to the control. Although higher LV stroke work was noted toward the third trimester (5.9±1.1 versus 5.3±1.0 Newton meter, P <0.001), ejection fraction showed no significant changes. LV strain decreased significantly in late pregnancy (−19.5±2% to −17.6±1.6%, P <0.001) and returned to baseline values after delivery (−19.5±2%). Conclusions—: Pregnancy is a physiological process associated with increased cardiac performance and progressive LV remodeling. These changes are not directly reflected by parameters traditionally considered to describe systolic function, such as ejection fraction and longitudinal deformation. While ejection fraction was insensitive to the functional changes, the transient decrease in longitudinal deformation becomes only plausible when considering the changes in LV geometry.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circimaging.111.970012

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 41 references

Cited by

See all 285

Metadata

Authors
Savu, O., Jurcuţ, R., Giuşcă, S., van Mieghem, T., Gussi, I., Popescu, B. A., Ginghină, C., Rademakers, F., Deprest, J., & Voigt, J.-U.
Venue
Circulation: Cardiovascular Imaging
Published
2012-05
Volume
5
Issue
3
Pages
289-297
ISSN
  • 1941-9651 (ISSN-L)
  • 1942-0080
OpenAlex
W2117457650
Cited by
285
References
41
FWCI
10.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Morphological and Functional Adaptation of the Maternal Heart During Pregnancy. https://app.cochat.ai/papers/10.1161/circimaging.111.970012
The paper
Savu, O., Jurcuţ, R., Giuşcă, S., van Mieghem, T., Gussi, I., Popescu, B. A., Ginghină, C., Rademakers, F., Deprest, J., & Voigt, J.-U. (2012). Morphological and Functional Adaptation of the Maternal Heart During Pregnancy. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.111.970012

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.