CoChat

Interstitial Fibrosis, Functional Status, and Outcomes in Heart Failure With Preserved Ejection Fraction: Insights From a Prospective Cardiac Magnetic Resonance Imaging Study

Duca, Franz, Kammerlander, Andreas A., Zotter-Tufaro, Caroline, Aschauer, Stefan, Schwaiger, Marianne L., Marzluf, Beatrice A., Bonderman, Diana, Mascherbauer, Julia · 2016 · Circulation: Cardiovascular Imaging
Cited by 139

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Background—: Myocardial extracellular volume (ECV) accumulation is one of the key pathophysiologic features of heart failure with preserved ejection fraction (HFpEF). Our aims were to (1) measure ECV by cardiac magnetic resonance T1 mapping using the modified Look-Locker inversion recovery (MOLLI) sequence, (2) validate MOLLI-ECV against histology, and (3) investigate the relationship between MOLLI-ECV and prognosis in HFpEF. Methods and Results—: One-hundred seventeen consecutive HFpEF patients underwent cardiac magnetic resonance imaging, coronary angiography, and invasive hemodynamic assessments at baseline. Eighteen patients also underwent left ventricular biopsy for histological analysis (Histo-ECV). To assess the prognostic impact of MOLLI-ECV, its association with hospitalization for heart failure/cardiac death was tested by multivariable Cox regression analysis. Histo-ECV was 30.1±4.6% and was significantly correlated with MOLLI-ECV ( R =0.494, P =0.037). Patients were followed for 24.0 months (6.0–32.0 months), during which 34 had a cardiac event. By Kaplan–Meier analysis, patients with MOLLI-ECV ≥ the median (28.9%) had shorter event-free survival (log-rank, P =0.028). MOLLI-ECV significantly correlated with N-terminal prohormone of brain natriuretic peptide ( P <0.001), 6-minute walk distance ( P =0.004), New York Heart Association functional class ( P =0.009), right atrial pressure ( P =0.037), and stroke volume ( P =0.043). By multivariable Cox regression analysis, MOLLI-ECV was associated with outcome among imaging variables ( P =0.038) but not after adjustment for clinical and invasive hemodynamic parameters. Conclusions—: We demonstrate that MOLLI-ECV in HFpEF accurately reflects histological ECV, correlates with markers of disease severity, and is associated with outcome among cardiac magnetic resonance parameters but not after adjustment for important clinical and invasive hemodynamic parameters. Nevertheless, MOLLI-ECV has the potential of becoming an important biomarker in HFpEF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circimaging.116.005277

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Duca, F., Kammerlander, A. A., Zotter-Tufaro, C., Aschauer, S., Schwaiger, M. L., Marzluf, B. A., Bonderman, D., & Mascherbauer, J.
Venue
Circulation: Cardiovascular Imaging
Published
2016-12
Volume
9
Issue
12
ISSN
  • 1941-9651 (ISSN-L)
  • 1942-0080
OpenAlex
W3014645859
Cited by
139
References
6
FWCI
12.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.