Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 158

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Prosthesis Oversizing in Balloon-Expandable Transcatheter Aortic Valve Implantation Is Associated With Contained Rupture of the Aortic Root

Open access
Blanke, Philipp, Reinöhl, Jochen, Schlensak, Christian, Siepe, Matthias, Pache, Gregor, Euringer, Wulf, Geibel-Zehender, Annette, Bode, Christopher, Langer, Mathias, Beyersdorf, Friedhelm, Zehender, Manfred·2012·Circulation: Cardiovascular Interventions

Abstract

Background—: To retrospectively investigate the potential cause of contained rupture of the aortic root in balloon-expandable transcatheter aortic valve implantation (TAVI) by means of pre- and postinterventional multislice computed tomography. Methods and Results—: Seventy-two patients (mean age 82±7 years, mean aortic valve area 0.69±0.19 cm 2 ) underwent balloon-expandable TAVI using the EdwardsSAPIEN Transcatheter Heart Valve (23 mm, n=19; 26 mm, n=50; 29 mm, n=3). Aortic annulus dimensions were quantified by multislice computed tomography–based cross-sectional area assessment and average diameter calculation (CAAD) before and after TAVI. Post-TAVI multislice computed tomography data sets were available in 65 patients; contained aortic root rupture was diagnosed in 3 patients. Pre-TAVI CAAD was 23.1±1.8 mm; post-TAVI CAAD was 22.9±1.3 mm. Median relative change in CAAD pre- and post-TAVI was −0.5% (interquartile range, 3.6%). Relative increase of 5% to 10% was observed in 4 patients (1 with contained rupture), relative increase >10% in 2 patients, both with contained rupture. Mean relative oversizing, calculated as the relative difference in diameter between pre-TAVI CAAD and nominal diameter of the selected prosthesis, was 9.8%±7.8%. Relative oversizing was significantly higher in patients with contained rupture compared with patients without contained rupture (24.6%±5.4% versus 9.1%±6.6%; P <0.001). Relative oversizing ≥20% occurred in 6 patients (3 with contained rupture). Conclusions—: Contained rupture of the aortic root in balloon-expandable TAVI is associated with severe prosthesis oversizing. Multislice computed tomography–based assessment of aortic annulus dimension in conjunction with adapted sizing guidelines may reduce the incidence of severe oversizing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circinterventions.111.967349

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 158

Metadata

Authors
Blanke, P., Reinöhl, J., Schlensak, C., Siepe, M., Pache, G., Euringer, W., Geibel-Zehender, A., Bode, C., Langer, M., Beyersdorf, F., & Zehender, M.
Venue
Circulation: Cardiovascular Interventions
Published
2012-08
Volume
5
Issue
4
Pages
540-548
ISSN
  • 1941-7632 (ISSN-L)
  • 1941-7640
OpenAlex
W2160308897
Cited by
158
References
4
FWCI
11.51
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prosthesis Oversizing in Balloon-Expandable Transcatheter Aortic Valve Implantation Is Associated With Contained Rupture of the Aortic Root. https://app.cochat.ai/papers/10.1161/circinterventions.111.967349
The paper
Blanke, P., Reinöhl, J., Schlensak, C., Siepe, M., Pache, G., Euringer, W., Geibel-Zehender, A., Bode, C., Langer, M., Beyersdorf, F., & Zehender, M. (2012). Prosthesis Oversizing in Balloon-Expandable Transcatheter Aortic Valve Implantation Is Associated With Contained Rupture of the Aortic Root. Circulation: Cardiovascular Interventions. https://doi.org/10.1161/circinterventions.111.967349

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.