Anatomical and Procedural Features Associated With Aortic Root Rupture During Balloon-Expandable Transcatheter Aortic Valve Replacement

Open access
Barbanti, Marco, Yang, Tae-Hyun, Rodès Cabau, Josep, Tamburino, Corrado, Wood, David A., Jilaihawi, Hasan, Blanke, Phillip, Makkar, Raj R., Latib, Azeem, Colombo, Antonio, Tarantini, Giuseppe, Raju, Rekha, Binder, Ronald K., Nguyen, Giang, Freeman, Melanie, Ribeiro, Henrique B., Kapadia, Samir, Min, James, Feuchtner, Gudrun, Gurtvich, Ronen, Alqoofi, Faisal, Pelletier, Marc, Ussia, Gian Paolo, Napodano, Massimo, de Brito, Fabio Sandoli, Kodali, Susheel, Norgaard, Bjarne L., Hansson, Nicolaj C., Pache, Gregor, Canovas, Sergio J., Zhang, Hongbin, Leon, Martin B., Webb, John G., Leipsic, Jonathon·2013·Circulation

Abstract

Background—: Aortic root rupture is a major concern with balloon-expandable transcatheter aortic valve replacement (TAVR). We sought to identify predictors of aortic root rupture during balloon-expandable TAVR by using multidetector computed tomography. Methods and Results—: Thirty-one consecutive patients who experienced left ventricular outflow tract (LVOT)/annular/aortic contained/noncontained rupture during TAVR were collected from 16 centers. A caliper-matched sample of 31 consecutive patients without annular rupture, who underwent pre-TAVR multidetector computed tomography served as a control group. Multidetector computed tomography assessment included short- and long-axis diameters and cross-sectional area of the sinotubular junction, annulus, and LVOT, and the presence, location, and extent of calcification of the LVOT, as well. There were no significant differences between the 2 groups in any preoperative clinical and echocardiographic variables. Aortic root rupture was identified in 20 patients and periaortic hematoma in 11. Patients with root rupture had a higher degree of subannular/LVOT calcification quantified by the Agatston score (181.2±211.0 versus 22.5±37.6, P <0.001), and a higher frequency of ≥20% annular area oversizing (79.4% versus 29.0%, P <0.001) and balloon postdilatation (22.6% versus 0.0%, P =0.005). In conditional logistic regression analysis for the matched data, moderate/severe LVOT/subannular calcifications (odds ratio, 10.92; 95% confidence interval, 3.23–36.91; P <0.001) and prosthesis oversizing ≥20% (odds ratio, 8.38; 95% confidence interval, 2.67–26.33; P <0.001) were associated with aortic root contained/noncontained rupture. Conclusions—: This study demonstrates that LVOT calcification and aggressive annular area oversizing are associated with an increased risk of aortic root rupture during TAVR with balloon-expandable prostheses. Larger studies are warranted to confirm these findings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.113.002947

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 601

Metadata

Authors
Barbanti, M., Yang, T.-H., Rodès Cabau, J., Tamburino, C., Wood, D. A., Jilaihawi, H., Blanke, P., Makkar, R. R., Latib, A., Colombo, A., Tarantini, G., Raju, R., Binder, R. K., Nguyen, G., Freeman, M., Ribeiro, H. B., Kapadia, S., Min, J., Feuchtner, G., Gurtvich, R., Alqoofi, F., Pelletier, M., Ussia, G. P., Napodano, M., de Brito, F. S., Kodali, S., Norgaard, B. L., Hansson, N. C., Pache, G., Canovas, S. J., Zhang, H., Leon, M. B., Webb, J. G., & Leipsic, J.
Venue
Circulation
Published
2013-07-16
Volume
128
Issue
3
Pages
244-253
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2143427268
Cited by
601
References
14
FWCI
31.99
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Anatomical and Procedural Features Associated With Aortic Root Rupture During Balloon-Expandable Transcatheter Aortic Valve Replacement. https://app.cochat.ai/papers/10.1161/circulationaha.113.002947
The paper
Barbanti, M., Yang, T.-H., Rodès Cabau, J., Tamburino, C., Wood, D. A., Jilaihawi, H., Blanke, P., Makkar, R. R., Latib, A., Colombo, A., Tarantini, G., Raju, R., Binder, R. K., Nguyen, G., Freeman, M., Ribeiro, H. B., Kapadia, S., Min, J., Feuchtner, G., . . . Leipsic, J. (2013). Anatomical and Procedural Features Associated With Aortic Root Rupture During Balloon-Expandable Transcatheter Aortic Valve Replacement. Circulation. https://doi.org/10.1161/circulationaha.113.002947

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.