CoChat

Shock and Patient Preimplantation Type D Personality Are Associated With Poor Health Status in Patients With Implantable Cardioverter-Defibrillator

Open access
Pedersen, Susanne S., Tekle, Fetene B., Hoogwegt, Madelein T., Jordaens, Luc, Theuns, Dominic A.M.J. · 2012 · Circulation: Cardiovascular Quality and Outcomes
Cited by 28

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Background—: Implantable cardioverter-defibrillator (ICD) shock is a critical event to patients associated with well-being after implantation, although other factors may play an equally important role. We compared the association of shock and the patient's preimplantation personality with health status, using a prospective study design. Methods and Results—: Consecutively implanted ICD patients (n=383; 79% men) completed the Type D Scale at baseline and the Short-Form Health Survey 36 (SF-36) at baseline and 3, 6, and 12 months. Of all patients, 23.5% had a Type D personality and 13.8% received a shock during follow-up. Shocked patients reported significantly poorer health status, as did Type D patients. Health status patterns were poorest in patients with combined Type D personality and shock during follow-up. Shock during follow-up was a significant independent associate of poorer health status for 4 of 8 subscales of the SF-36 and the Mental Component Summary (all P <.05), with shocked patients scoring between 2.60 to 13.30 points lower than nonshocked patients. Type D personality was an independent associate of poor postimplantation health status for 6 of 8 of the SF-36 subscales and the Mental Component Summary, with Type D patients scoring between 2.12 to 8.02 points lower, adjusting for demographic and clinical characteristics. Conclusions—: ICD shock and the patient's preimplantation personality disposition were equally important associates of health status 12 months after implantation. Identification of the patient's personality profile before ICD implantation may help identify subsets of patients who may need additional care, for example, with a psychosocial component.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circoutcomes.111.964197

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 28

Metadata

Authors
Pedersen, S. S., Tekle, F. B., Hoogwegt, M. T., Jordaens, L., & Theuns, D. A. M. J.
Venue
Circulation: Cardiovascular Quality and Outcomes
Published
2012-05
Volume
5
Issue
3
Pages
373-380
ISSN
  • 1941-7705 (ISSN-L)
  • 1941-7713
OpenAlex
W2098606668
Cited by
28
References
8
FWCI
2.49
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Shock and Patient Preimplantation Type D Personality Are Associated With Poor Health Status in Patients With Implantable Cardioverter-Defibrillator. https://app.cochat.ai/papers/10.1161/circoutcomes.111.964197
The paper
Pedersen, S. S., Tekle, F. B., Hoogwegt, M. T., Jordaens, L., & Theuns, D. A. M. J. (2012). Shock and Patient Preimplantation Type D Personality Are Associated With Poor Health Status in Patients With Implantable Cardioverter-Defibrillator. Circulation: Cardiovascular Quality and Outcomes. https://doi.org/10.1161/circoutcomes.111.964197

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.