CoChat

High-Resolution 3-Dimensional Reconstruction of the Infarct Border Zone: Impact of Structural Remodeling on Electrical Activation

Rutherford, Sally L., Trew, Mark L., Sands, Gregory B., LeGrice, Ian J., Smaill, Bruce H. · 2012 · Circulation Research
Cited by 114

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Rationale: Slow nonuniform electric propagation in the border zone (BZ) of a healed myocardial infarct (MI) can give rise to reentrant arrhythmia. The extent to which this is influenced by structural rather than cellular electric remodeling is unclear. Objective: To determine whether structural remodeling alone in the infarct BZ could provide a substrate for re-entry by (i) characterizing the 3-dimensional (3D) structure of the myocardium surrounding a healed MI at high spatial resolution and (ii) modeling electric activation on this structure. Methods and Results: Anterior left ventricular (LV) infarcts were induced in 2 rats by coronary artery ligation. Three-dimensional BZ volume (4.1 mm 3 and 5.6 mm 3 ) were imaged at 14 days using confocal microscopy. Viable myocytes were identified, and their connectivity and orientation were quantified. Preserved cell networks were observed in the subendocardium and subepicardium of the infarct. Myocyte tracts traversed the BZ, and there was heavy infiltration of collagen into the adjacent myocardium. Myocyte connectivity decreased by ≈65% over 250 μm across the BZ. This structure was incorporated into 3D network models on which activation was simulated using Luo–Rudy membrane dynamics assuming normal cellular electric properties. Repetitive stimulation was imposed at selected BZ sites. Stimulus site-specific unidirectional propagation occurred in the BZ with rate-dependent slowing and conduction block, and reentry was demonstrated in one substrate. Activation times were prolonged because of tract path length and local slowing. Conclusions: We have used a detailed image-based model of the infarct BZ to demonstrate that structural heterogeneity provides a dynamic substrate for electric reentry.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circresaha.111.260943

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 114

Metadata

Authors
Rutherford, S. L., Trew, M. L., Sands, G. B., LeGrice, I. J., & Smaill, B. H.
Venue
Circulation Research
Published
2012-07-20
Volume
111
Issue
3
Pages
301-311
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2138984876
Cited by
114
References
2
FWCI
5.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.