The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
A Conductive Polymer Hydrogel Supports Cell Electrical Signaling and Improves Cardiac Function After Implantation into Myocardial Infarct
Open accessAbstract
Background—: Efficient cardiac function requires synchronous ventricular contraction. After myocardial infarction, the nonconductive nature of scar tissue contributes to ventricular dysfunction by electrically uncoupling viable cardiomyocytes in the infarct region. Injection of a conductive biomaterial polymer that restores impulse propagation could synchronize contraction and restore ventricular function by electrically connecting isolated cardiomyocytes to intact tissue, allowing them to contribute to global heart function. Methods and Results—: We created a conductive polymer by grafting pyrrole to the clinically tested biomaterial chitosan to create a polypyrrole (PPy)-chitosan hydrogel. Cyclic voltammetry showed that PPy-chitosan had semiconductive properties lacking in chitosan alone. PPy-chitosan did not reduce cell attachment, metabolism, or proliferation in vitro. Neonatal rat cardiomyocytes plated on PPy-chitosan showed enhanced Ca 2+ signal conduction in comparison with chitosan alone. PPy-chitosan plating also improved electric coupling between skeletal muscles placed 25 mm apart in comparison with chitosan alone, demonstrating that PPy-chitosan can electrically connect contracting cells at a distance. In rats, injection of PPy-chitosan 1 week after myocardial infarction decreased the QRS interval and increased the transverse activation velocity in comparison with saline or chitosan, suggesting improved electric conduction. Optical mapping showed increased activation in the border zone of PPy-chitosan–treated rats. Echocardiography and pressure–volume analysis showed improvement in load-dependent (ejection fraction, fractional shortening) and load-independent (preload recruitable stroke work) indices of heart function 8 weeks after injection. Conclusions—: We synthesized a biocompatible conductive biomaterial (PPy-chitosan) that enhances biological conduction in vitro and in vivo. Injection of PPy-chitosan better maintained heart function after myocardial infarction than a nonconductive polymer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synthesis of electrically conducting organic polymers: halogen derivatives of polyacetylene, (CH) x
Shirakawa, H., Louis, E. J., MacDiarmid, A. G., Chiang, C. K., & Heeger, A. J. (1977) · Journal of the Chemical Society, Chemical Communications · doi:10.1039/c39770000578 · Cited by 3,867
Chitosan-based hydrogels for controlled, localized drug delivery
Bhattarai, N., Gunn, J., & Zhang, M. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.07.019 · Cited by 2,451
Biomedical applications of biodegradable polymers
Ulery, B. D., Nair, L. S., & Laurencin, C. T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22259 · Cited by 2,206
Go, A. S., Mozaffarian, D., Roger, V. L., Benjamin, E. J., Berry, J. D., Blaha, M. J., Dai, S., Ford, E. S., Fox, C. S., Franco, S., et al. (2014) · Circulation · doi:10.1161/01.cir.0000442015.53336.12 · Cited by 1,408
Stimulation of neurite outgrowth using an electrically conducting polymer
Schmidt, C. E., Shastri, V. R., Vacanti, J. P., & Langer, R. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.17.8948 · Cited by 1,071
Engler, A. J., Carag-Krieger, C., Johnson, C. P., Raab, M., Tang, H.-Y., Speicher, D. W., Sanger, J. W., Sanger, J. M., & Discher, D. E. (2008) · Journal of Cell Science · doi:10.1242/jcs.029678 · Cited by 865
Cardiac-Resynchronization Therapy in Heart Failure with a Narrow QRS Complex
Ruschitzka, F., Abraham, W. T., Singh, J. P., Bax, J. J., Borer, J. S., Brugada, J., Dickstein, K., Ford, I., Gorcsan, J., Gras, D., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1306687 · Cited by 825
Kotwal, A. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00344-6 · Cited by 518
Evaluation of biocompatibility of polypyrrole in vitro and in vivo
Wang, X., Gu, X., Yuan, C., Chen, S., Zhang, P., Zhang, T., Yao, J., Chen, F., & Chen, G. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.20065 · Cited by 453
Synthesis of a Novel, Biodegradable Electrically Conducting Polymer for Biomedical Applications
Rivers, T. J., Hudson, T. W., & Schmidt, C. E. (2002) · Advanced Functional Materials · doi:10.1002/1616-3028(20020101)12:1<33::aid-adfm33>3.0.co;2-e · Cited by 423
Cited by
Functional and Biomimetic Materials for Engineering of the Three-Dimensional Cell Microenvironment
Huang, G., Li, F., Zhao, X., Ma, Y., Li, Y., Lin, M., Jin, G., Lu, T. J., Genin, G. M., & Xu, F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00094 · Cited by 825
Liu, Z., Wan, X., Wang, Z. L., & Li, L. (2021) · Advanced Materials · doi:10.1002/adma.202007429 · Cited by 478
Metadata
- Authors
- Mihic, A., Cui, Z., Wu, J., Vlacic, G., Miyagi, Y., Li, S.-H., Lu, S., Sung, H.-W., Weisel, R. D., & Li, R.-K.
- Venue
- Circulation
- Published
- 2015-08-25
- Volume
- 132
- Issue
- 8
- Pages
- 772-784
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1937519362
- Cited by
- 275
- References
- 36
- FWCI
- 13.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Conductive Polymer Hydrogel Supports Cell Electrical Signaling and Improves Cardiac Function After Implantation into Myocardial Infarct. https://app.cochat.ai/papers/10.1161/circulationaha.114.014937
- The paper
- Mihic, A., Cui, Z., Wu, J., Vlacic, G., Miyagi, Y., Li, S.-H., Lu, S., Sung, H.-W., Weisel, R. D., & Li, R.-K. (2015). A Conductive Polymer Hydrogel Supports Cell Electrical Signaling and Improves Cardiac Function After Implantation into Myocardial Infarct. Circulation. https://doi.org/10.1161/circulationaha.114.014937
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.