The DOI matches its Crossref record, with a small difference in title or year; 14 of the 14 references it cites were found in a registry or an index.
Perception of Atrial Fibrillation Before and After Radiofrequency Catheter Ablation: Relevance of Asymptomatic Arrhythmia Recurrence
Abstract
Background— The objective of this study was to assess the incidence and impact of asymptomatic arrhythmia in patients with highly symptomatic atrial fibrillation (AF) who qualified for radiofrequency (RF) catheter ablation. Methods and Results— In this prospective study, 114 patients with at least 3 documented AF episodes together with corresponding symptoms and an ineffective trial of at least 1 antiarrhythmic drug were selected for RF ablation. With the use of CARTO, circumferential lesions around the pulmonary veins and linear lesions at the roof of the left atrium and along the left atrial isthmus were placed. A continuous, 7-day, Holter session was recorded before ablation, right after ablation, and after 3, 6, and 12 months of follow-up. During each 7-day Holter monitoring, the patients recorded quality and duration of any complaints by using a detailed symptom log. More than 70 000 hours of ECG recording were analyzed. In the 7-day Holter records before ablation, 92 of 114 patients (81%) had documented AF episodes. All episodes were symptomatic in 35 patients (38%). In 52 patients (57%), both symptomatic and asymptomatic episodes were recorded, whereas in 5 patients (5%), all documented AF episodes were asymptomatic. After ablation, the percentage of patients with only asymptomatic AF recurrences increased to 37% ( P <0.05) at the 6-month follow-up. An analysis of patient characteristics and arrhythmia patterns failed to identify a specific subset who were at high risk for the development of asymptomatic AF. Conclusions— Even in patients presenting with highly symptomatic AF, asymptomatic episodes may occur and significantly increase after catheter ablation. A symptom-only–based follow-up would substantially overestimate the success rate. Objective measures such as long-term Holter monitoring are needed to identify asymptomatic AF recurrences after ablation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Indeed, catheter ablation may increase the proportion of AF events that are asymptomatic, probably by alteration of cardiac neural element (Hindricks et al., 2005).”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Hindricks et al., 2005
Experimental — accuracy not yet measuredIn the citing paper
“Patient should also be aware that symptomatic and asymptomatic AF recurrences are frequent after catheter ablation.119,781,782”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [119]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins.
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Mouroux, A. L., Métayer, P. L., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 8,040
Pappone, C., Santinelli, V., Manguso, F., Vicedomini, G., Gugliotta, F., Augello, G., Mazzone, P., Tortoriello, V., Landoni, G., Zangrillo, A., et al. (2004) · Circulation · doi:10.1161/01.cir.0000112641.16340.c7 · Cited by 1,018
Catheter Ablation for Paroxysmal Atrial Fibrillation
Oral, H., Scharf, C., Chugh, A., HALL, B. W., Cheung, P. W., Good, E. D., Veerareddy, S., Pelosi, F., & Morady, F. (2003) · Circulation · doi:10.1161/01.cir.0000095796.45180.88 · Cited by 896
Pappone, C., Rosanio, S., Augello, G., Gallus, G., Vicedomini, G., Mazzone, P., Gulletta, S., Gugliotta, F., Pappone, A., Santinelli, V., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00577-1 · Cited by 779
Page, R. L., Wilkinson, W. E., Clair, W. K., McCarthy, E. A., & Pritchett, E. L. (1994) · Circulation · doi:10.1161/01.cir.89.1.224 · Cited by 627 · cited 1×
“For patients with documented AF, the median total arrhythmia duration during the 7-day ECG periods measured 38 (10, 133) hours before ablation and postinterventionally declined to 36 (22, 79) hours immediately after ablation (P 0.”
BackgroundLong-term risk of recurrent atrial fibrillation as documented by an implantable monitoring device
Israel, C. W., Grönefeld, G., Ehrlich, J. R., Li, Y., & Hohnloser, S. H. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.027 · Cited by 478
Savelieva, I., & Camm, A. J. (2000) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/a:1009823001707 · Cited by 339
Kottkamp, H., Tanner, H., Kobza, R., Schirdewahn, P., Dorszewski, A., Gerds‐Li, J., Carbucicchio, C., Piorkowski, C., & Hindricks, G. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.04.049 · Cited by 196
Self-citationClinical Outcome after Radiofrequency Catheter Ablation of Focal Atrial Fibrillation Triggers
Gerstenfeld, E. P., Guerra, P. G., SPARKS, P. B., Hattori, K., & Lesh, M. D. (2001) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2001.00900.x · Cited by 191
Asymptomatic or “Silent” Atrial Fibrillation
Page, R. L., Tilsch, T. W., Connolly, S. J., Schnell, D., Marcello, S. R., Wilkinson, W. E., & Pritchett, E. L. C. (2003) · Circulation · doi:10.1161/01.cir.0000051455.44919.73 · Cited by 165
Flagged first, then by citations
Research works printed but not linked: 1
- 10.1161/circ.89.1.8281651 · DOI
Cited by
Sorted by citations
Items 101–200 of 507
Pérez‐Castellano, N., Cavazos, R. F., Moreno, J., Cañadas, V., Conde, A., González‐Ferrer, J. J., Macaya, C., & Pérez‐Villacastín, J. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2013.10.014 · Cited by 84
Comparison of elective stenting of severe vs moderate intracranial atherosclerotic stenosis
Jiang, W., Xu, X., Du, B., Dong, K. H., Jin, M., Wang, Q. H., & Ma, N. (2007) · Neurology · doi:10.1212/01.wnl.0000252939.60764.8e · Cited by 84
Venice Chart International Consensus Document on Atrial Fibrillation Ablation: 2011 Update
Raviele, A., Natale, A., Calkins, H. G., Camm, A. J., Cappato, R., Chen, S. A., Connolly, S. J., Damiano, R. J., Ponti, R. D., EDGERTON, J. R., et al. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2012.02381.x · Cited by 79
Self-citationRodgers, M., McKenna, C., Palmer, S., Chambers, D., Hout, S. V., Golder, S., Pepper, C., TODD, D. M., & Woolacott, N. F. (2008) · Health Technology Assessment · doi:10.3310/hta12340 · Cited by 79
Naruse, Y., Tada, H., Sekiguchi, Y., Machino, T., Ozawa, M., Yamasaki, H., Igarashi, M., Kuroki, K., Ito, Y., Murakoshi, N., et al. (2010) · Heart Rhythm · doi:10.1016/j.hrthm.2010.10.047 · Cited by 79
Diederichsen, S. Z., Haugan, K., Køber, L., Højberg, S., Brandes, A., Kronborg, C., Graff, C., Holst, A. G., Nielsen, J. B., Krieger, D. W., et al. (2017) · American Heart Journal · doi:10.1016/j.ahj.2017.02.017 · Cited by 74
Okada, T., Yamada, T., Murakami, Y., Yoshida, N., Ninomiya, Y., Shimizu, T., Toyama, J., Yoshida, Y., Ito, T., Tsuboi, N., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.10.076 · Cited by 73
Continuous monitoring after atrial fibrillation ablation: the LINQ AF study
Wechselberger, S., Kronborg, M. B., Huo, Y., Piorkowski, J., Neudeck, S., Päßler, E., El‐Armouche, A., Richter, U., Mayer, J., Ulbrich, S., et al. (2018) · EP Europace · doi:10.1093/europace/euy038 · Cited by 73
Self-citationProtracted CRP Elevation after Atrial Fibrillation Ablation
McCabe, J. M., Smith, L. M., Tseng, Z. H., Badhwar, N., Lee, B. K., Lee, R. J., Scheinman, M. M., Olgin, J. E., & Marcus, G. M. (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.01155.x · Cited by 72
Eitel, C., Husser, D., Hindricks, G., Frühauf, M., Hilbert, S., Arya, A., Gaspar, T., Wetzel, U., Bollmann, A., & Piorkowski, C. (2011) · EP Europace · doi:10.1093/europace/euq511 · Cited by 71
Self-citationMartinek, M., Aichinger, J., Nesser, H., Ziegler, P., & Pürerfellner, H. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00883.x · Cited by 69
Deep Learning of Electrocardiograms in Sinus Rhythm From US Veterans to Predict Atrial Fibrillation
Yuan, N., Duffy, G., Dhruva, S. S., Oesterle, A., Pellegrini, C. N., Theurer, J., Vali, M., Heidenreich, P. A., Keyhani, S., & Ouyang, D. (2023) · JAMA Cardiology · doi:10.1001/jamacardio.2023.3701 · Cited by 72
Ha, A. C. T., BREITHARDT, G. E., Camm, A. J., Crijns, H. J. G. M., Fitzmaurice, G. M., Kowey, P. R., Heuzey, J. L., Naditch‐Brûlé, L., Prystowsky, E. N., Schwartz, P. J., et al. (2014) · Circulation Cardiovascular Quality and Outcomes · doi:10.1161/hcq.0000000000000011 · Cited by 67
Metabolic Syndrome and Risk of Recurrence of Atrial Fibrillation After Catheter Ablation
Tang, R., Dong, J.-Z., Liu, X.-P., LONG, D., Yu, R.-H., Kalifa, J., & Ma, C.-S. (2009) · Circulation Journal · doi:10.1253/circj.cj-08-0832 · Cited by 62
An ultra-high input impedance ECG amplifier for long-term monitoring of athletes
Gargiulo (2010) · Medical Devices Evidence and Research · doi:10.2147/mder.s9321 · Cited by 63
Consensus document on antithrombotic therapy in the setting of electrophysiological procedures
Blanc, J. J., Almendral, J. M., Brignole, M., Fatemi, M., Gjesdal, K., González‐Torrecilla, E., Kułakowski, P., Lip, G. Y. H., Shah, D. C., & Wolpert, C. (2008) · EP Europace · doi:10.1093/europace/eun104 · Cited by 63
Hunter, R. J., Berriman, T., Diab, I. G., Baker, V., Finlay, M., Richmond, L., Duncan, E. R., Kamdar, R., Thomas, G., Abrams, D. J., et al. (2010) · Heart · doi:10.1136/hrt.2009.188128 · Cited by 62
JCS/JHRS 2022 Guideline on Diagnosis and Risk Assessment of Arrhythmia
Takase, B., Ikeda, T., Shimizu, W., Abe, H., Aiba, T., Chinushi, M., Koba, S., KUSANO, K. F., Niwano, S., Takahashi, N., et al. (2023) · Circulation Journal · doi:10.1253/circj.cj-22-0827 · Cited by 68
Ad, N., Barnett, S. D., Lefrak, E. A., Korach, A., Pollak, A., Gilon, D., & Elami, A. (2006) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2005.12.047 · Cited by 61
Camm, A. J., Savelieva, I., Ho, S. Y., Lindsay, B. D., Nattel, S., & Shinagawa, K. (2009) · Elsevier eBooks · doi:10.1016/b978-1-4377-0285-9.00044-2 · Cited by 60
AF burden is important - fact or fiction?
Boriani, G., Diemberger, I., Ziacchi, M., Valzania, C., Gardini, B., Cimaglia, P., Martignani, C., & Biffi, M. (2014) · International Journal of Clinical Practice · doi:10.1111/ijcp.12326 · Cited by 59
Challenges in the classification of atrial fibrillation
Lubitz, S. A., Benjamin, E. J., Ruskin, J. N., Fuster, V., & Ellinor, P. T. (2010) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2010.86 · Cited by 58
Pokushalov, E. A., Romanov, A. B., CORBUCCI, G., Байрамова, С. А., Losik, D., Туров, А. Н., Shirokova, N., Karaskov, A. M., Mittal, S., & Steinberg, J. S. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.03.047 · Cited by 57
Stulak, J. M., Dearani, J. A., Sundt, T. M., Daly, R. C., McGregor, C. G. A., Zehr, K. J., & Schaff, H. V. (2007) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2006.09.115 · Cited by 56
Winkle, R. A., Mead, R. H., Engel, G., Kong, M. H., & Patrawala, R. A. (2013) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-013-9835-1 · Cited by 55
Hunter, R. J., Ginks, M., Ang, R., Diab, I. G., Goromonzi, F., Page, S. P., Baker, V., Richmond, L., Tayebjee, M., Sporton, S. C., et al. (2010) · EP Europace · doi:10.1093/europace/euq322 · Cited by 53
Tayebjee, M. H., Creta, A., Moder, S., Hunter, R. J., Earley, M. J., Dhinoja, M., & Schilling, R. (2010) · EP Europace · doi:10.1093/europace/euq284 · Cited by 53
Pontoppidan, J., Nielsen, J. C., Poulsen, S. H., Jensen, H. K., Walfridsson, H., Pedersen, A. K., & HANSEN, P. S. (2009) · Heart · doi:10.1136/hrt.2008.153965 · Cited by 52
Härdén, M., Nyström, B., Kulich, K. R., Carlsson, J., Bengtson, A., & Edvardsson, N. G. (2009) · Health and Quality of Life Outcomes · doi:10.1186/1477-7525-7-65 · Cited by 52
Arimoto, T., Tada, H., Igarashi, M., Sekiguchi, Y., Sato, A., Koyama, T., Yamasaki, H., Machino, T., Kuroki, K., Kuga, K., et al. (2011) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02123.x · Cited by 52
Ambulatory ECG Monitoring in Atrial Fibrillation Management
Rosero, S. Z., Kutyifa, V., Olshansky, B., & Zaręba, W. (2013) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2013.10.001 · Cited by 51
Moreira, W., Timmermans, C. C., Wellens, H. J. J., Mizusawa, Y., Philippens, S., Perez, D., & Rodriguez, L. (2007) · Circulation · doi:10.1161/circulationaha.107.711622 · Cited by 51
Incidence of Late Thromboembolic Events After Catheter Ablation of Atrial Fibrillation
Yagishita, A., Takahashi, Y., Takahashi, A., Fujii, A., Kusa, S., Fujino, T., Nozato, T., Kuwahara, T., Hirao, K., & Isobe, M. (2011) · Circulation Journal · doi:10.1253/circj.cj-11-0065 · Cited by 50
A wearable device for recording of biopotentials and body movements
Bifulco, P., Cesarelli, M., Fratini, A., Ruffo, M., Pasquariello, G., & Gargiulo, G. D. (2011) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2011.5966735 · Cited by 49
Dhillon, G. S., Honarbakhsh, S., Monaco, A. D., Coling, A. E., Lenka, K., Pizzamiglio, F., Hunter, R. J., Horton, R., MANSOUR, M. C., Natale, A., et al. (2020) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14476 · Cited by 48
Dubner, S., Auricchio, A., Steinberg, J. S., Vardas, P., Stone, P., Brugada, J., Piotrowicz, R., Hayes, D. L., Kirchhof, P., Breithardt, G., et al. (2012) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2011.00484.x · Cited by 47
Early detection of occult atrial fibrillation and stroke prevention
Keach, J. W., Bradley, S. M., Turakhia, M. P., & Maddox, T. M. (2015) · Heart · doi:10.1136/heartjnl-2015-307588 · Cited by 45
Veenhuyzen, G. D., Knecht, S., O'Neill, M. D., Wright, M. J., Nault, I., Weerasooriya, R., Miyazaki, S., Sacher, F., Hocini, M., Jaı̈s, P., et al. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.02250.x · Cited by 45
Roten, L., Schilling, M., Haeberlin, A., Seiler, J., Schwick, N. G., Fuhrer, J., Delacrétaz, E., & Tanner, H. (2012) · Heart · doi:10.1136/heartjnl-2011-301455 · Cited by 45
Self-citationSteerable Sheath Catheter Navigation for Ablation of Atrial Fibrillation: A Case‐Control Study
Piorkowski, C., Kottkamp, H., Gerds‐Li, J., Arya, A., Sommer, P., Dagres, N., Esato, M., Riahi, S., WEISS, S., Kircher, S., et al. (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.01101.x · Cited by 44
Self-citationTscholl, V., Lsharaf, A. K., Lin, T., Bellmann, B., Biewener, S., Nagel, P., Suhail, S., Lenz, K., Landmesser, U., Roser, M., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.05.022 · Cited by 43
Tondo, C., Tritto, M. V., Landolina, M., GIROLAMO, P. D., Bencardino, G., Moltrasio, M., Russo, A. D., Bella, P. E. D., Bertaglia, E., Proclemer, A., et al. (2013) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12292 · Cited by 42
Wazni, O. M., Boersma, L. V. A., Healey, J. S., MANSOUR, M. C., Tondo, C., Phillips, K. P., Doshi, R. N., Jaber, W. A., Hynes, E., Allocco, D. J., et al. (2022) · American Heart Journal · doi:10.1016/j.ahj.2022.05.003 · Cited by 42
Quality of life in older people with atrial fibrillation
Lane, D. A., & Lip, G. Y. H. (2008) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-008-9318-y · Cited by 42
Aytemir, K., Oto, A., Canpolat, U., Sunman, H., Yorgun, H., ŞAHINER, L., & Kaya, E. B. (2013) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-013-9834-2 · Cited by 41
Björkenheim, A., Brandes, A., Magnuson, A., Chemnitz, A., Svedberg, L., Edvardsson, N. G., & Poçi, D. (2017) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2017.04.003 · Cited by 41
Pontoppidan, J., Nielsen, J. C., Poulsen, S. H., & HANSEN, P. S. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02357.x · Cited by 40
Ito, Y., Yamasaki, H., Naruse, Y., Yoshida, K., Kaneshiro, T., Murakoshi, N., Igarashi, M., Kuroki, K., Machino, T., Xu, D., et al. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2012.12.020 · Cited by 40
Aljuaid, M., Marashly, Q., Danaf, J. A., Tawhari, I. H., Barakat, M. M., Barakat, R., Zobell, B., Cho, W., Chelu, M. G., & Marrouche, N. F. (2020) · Clinical Medicine Insights Cardiology · doi:10.1177/1179546820901508 · Cited by 40
Verma, A., Minor, S., Kılıçaslan, F., Patel, D., Hao, S. C., Beheiry, S., Lakkireddy, D., Elayi, S. C., Cummings, J. E., Martin, D. O., et al. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00789.x · Cited by 40
Absence of Correlation Between Symptoms and Rhythm in “Symptomatic” Atrial Fibrillation
Mehall, J. R., Kohut, R. M., Schneeberger, E. W., Merrill, W. H., & Wolf, R. K. (2007) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2007.02.084 · Cited by 40
Modified Maze During Endoscopic Mitral Valve Surgery: The OLV Clinic Experience
Jeanmart, H., Casselman, F. P. A., Beelen, R., Wellens, F., Bakır, İ., Praet, F. V., Cammu, G., Degrieck, Y., Vermeulen, Y., & Vanermen, H. K. (2006) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2006.05.051 · Cited by 40
Should We Perform Catheter Ablation for Asymptomatic Atrial Fibrillation?
Kalman, J. M., Sanders, P., Rosso, R., & Calkins, H. G. (2017) · Circulation · doi:10.1161/circulationaha.116.024926 · Cited by 42
Peri-procedural anticoagulation in patients undergoing ablation for atrial fibrillation
Vazquez, S. R., Johnson, S. A., & Rondina, M. T. (2010) · Thrombosis Research · doi:10.1016/j.thromres.2009.11.031 · Cited by 40
Dong, J., Liu, X., Long, D., Yu, R., Tang, R., Lü, F., & Ma, C. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01324.x · Cited by 39
Asymptomatic recurrences of atrial fibrillation after pulmonary vein isolation
Neumann, T., Erdoğan, A., Dill, T., Greiß, H., Berkowitsch, A., Sperzel, J., Kuniss, M., Kurzidim, K. W., Hamm, C. W., & Pitschner, H.-F. (2006) · EP Europace · doi:10.1093/europace/eul056 · Cited by 38
Updated NICE guideline: management of atrial fibrillation (2014)
Senoo, K., Lau, Y. C., & Lip, G. Y. H. (2014) · Expert Review of Cardiovascular Therapy · doi:10.1586/14779072.2014.943189 · Cited by 40
Anticoagulation Management Pre- and Post Atrial Fibrillation Ablation: A Survey of Canadian Centres
Mardigyan, V., Verma, A., Birnie, D. H., Guerra, P. G., Redfearn, D., Becker, G., Champagne, J., Sapp, J. L., Gula, L. J., Parkash, R., et al. (2012) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2012.04.013 · Cited by 38
Garimella, R. S., Chung, E. H., Mounsey, J. P., Schwartz, J., Pursell, I. W., & Gehi, A. K. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.01.012 · Cited by 37
Disertori, M., Lombardi, F., Barlera, S., Maggioni, A. P., Favero, C., Franzosi, M. G., Lucci, D., Staszewsky, L. I., Fabbri, G., Quintarelli, S., et al. (2011) · American Heart Journal · doi:10.1016/j.ahj.2011.05.008 · Cited by 37
Ciconte, G., Saviano, M., Giannelli, L., Ćalović, Ž., Baldi, M., Ciaccio, C., Cuko, A., Vitale, R., Giacopelli, D., Conti, M. A., et al. (2016) · EP Europace · doi:10.1093/europace/euw181 · Cited by 36
Morphological Changes of the Left Atrial Appendage After Catheter Ablation of Atrial Fibrillation
Chang, S., TSAO, H., Wu, M., Tai, C., Chang, S., Wongcharoen, W., Lin, Y., LO, L., HSIEH, M., Sheu, M., et al. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00655.x · Cited by 37
The Role of Implantable Cardiac Monitors in Atrial Fibrillation Management
Ciconte, G., Giacopelli, D., & Pappone, C. (2017) · Journal of Atrial Fibrillation · doi:10.4022/jafib.1590 · Cited by 36
Okumura, Y., Nagashima, K., Arai, M., Watanabe, R., Yokoyama, K., Matsumoto, N., Otsuka, T., Suzuki, S. S., Hirata, A., Murakami, M., et al. (2019) · Circulation Journal · doi:10.1253/circj.cj-19-0602 · Cited by 35
Pharmacological and Electrical Conversion of Atrial Fibrillation to Sinus Rhythm Is Worth the Effort
Anter, E., & Callans, D. J. (2009) · Circulation · doi:10.1161/circulationaha.108.824847 · Cited by 34
Catheter ablation of atrial fibrillation as first-line therapy--a single-centre experience
Tanner, H., Makowski, K., Roten, L., Seiler, J., Schwick, N. G., Muller, C., Fuhrer, J., & Delacrétaz, E. (2011) · EP Europace · doi:10.1093/europace/eur065 · Cited by 34
Self-citationBiase, L. D., Lakkireddy, D. J., Marazzato, J., Velasco, A., Díaz, J. C., Navara, R., Chrispin, J., Rajagopalan, B., Natale, A., Mohanty, S., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.09.831 · Cited by 34
Pedrote, A. A., Arana‐Rueda, E., García‐Riesco, L., Sánchez-Brotons, J. A., DURÁN‐GUERRERO, M., Gómez‐Pulido, F., Arce‐León, Á., & Frutos‐López, M. (2013) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12190 · Cited by 32
SIMANTIRAKIS, E. N., Papakonstantinou, P. Ε., KANOUPAKIS, E. M., CHLOUVERAKIS, G. I., Tzeis, S. E., & Vardas, P. E. (2018) · Clinical Cardiology · doi:10.1002/clc.22904 · Cited by 32
Nedios, S., Romero, I., Gerds‐Li, J., FLECK, E., & Kriatselis, C. (2014) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2014.04.003 · Cited by 31
Self-citationCatheter and surgical ablation of atrial fibrillation
Earley, M. J., & SCHILLING, R. J. (2006) · Heart · doi:10.1136/hrt.2005.067389 · Cited by 32
Aydın, M., Gökkuşu, C., Özkök, E., Tülübaş, F., Ünlüçerçi, Y., Pamukçu, B., Ozbek, Z., & Umman, B. (2009) · Molecular and Cellular Biochemistry · doi:10.1007/s11010-009-0038-0 · Cited by 30
Verdoia, M., Nardin, M., Gioscia, R., Afifeh, A. M. S., Viglione, F., Negro, F., Marcolongo, M., Luca, G. D., & the Novara Atherosclerosis Study Group (NAS) (2021) · Journal of Thrombosis and Thrombolysis · doi:10.1007/s11239-021-02391-w · Cited by 30
Solheim, E., Off, M. K., Hoff, P. I., Bortoli, A. M. D., Schuster, P. M., Ohm, O., & Chen, J. (2011) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-011-9629-2 · Cited by 29
SIMANTIRAKIS, E. N., Papakonstantinou, P. Ε., CHLOUVERAKIS, G. I., Kanoupakis, E. M., Mavrakis, H. E., Kallergis, E. M., Arkolaki, E. G., & Vardas, P. E. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.12.025 · Cited by 29
Role of Atrial Fibrillation Burden in Assessing Thromboembolic Risk
ZIMETBAUM, P. J., Waks, J. W., Ellis, E. R., Glotzer, T. V., & PASSMAN, R. S. (2014) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.114.001356 · Cited by 28
Long-term monitoring after surgical ablation for atrial fibrillation: How much is enough?
Edgerton, J. R., Mahoney, C., Mack, M. J., Roper, K. L., & Herbert, M. A. (2011) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2011.01.050 · Cited by 28
Mulder, A. A. W., WIJFFELS, M. C. E. F., WEVER, E. F. D., & Boersma, L. V. A. (2012) · EP Europace · doi:10.1093/europace/eus010 · Cited by 28
Hermans, A. N. L., Gawalko, M. M., Slegers, D. P. J., Andelfinger, N., Pluymaekers, N. A. H. A., Verhaert, D. V. M., van der Velden, R. M. J., Betz, K., Evens, S., LUERMANS, J. G. L. M., et al. (2022) · International Journal of Cardiology · doi:10.1016/j.ijcard.2022.08.021 · Cited by 28
Viles-González, J. F., & Mehta, D. (2010) · Current Cardiology Reports · doi:10.1007/s11886-010-0153-2 · Cited by 28
Wasmer, K., BREITHARDT, G. E., & Eckardt, L. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu113 · Cited by 29
Silent Atrial Fibrillation: A Critical Review.
Barbarossa, A., Guerra, F., & Capucci, A. (2014) · Europe PMC (PubMed Central) · doi:10.4022/jafib.1138 · Cited by 27
Kurosaki, K., Tada, H., Hashimoto, T., Ito, S., Miyaji, K., Naito, S., Oshima, S., & Taniguchi, K. (2007) · Circulation Journal · doi:10.1253/circj.71.313 · Cited by 28
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström‐Lundqvist, C., Boriani, G., Castellà, M., Dan, G., Dilaveris, P., et al. (2021) · Revista Española de Cardiología · doi:10.1016/j.recesp.2020.10.022 · Cited by 33
Self-citationSilent Atrial Fibrillation as a Stroke Risk Factor and Anticoagulation Indication
Glotzer, T. V., & Ziegler, P. (2013) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2013.03.023 · Cited by 27
Moreira, W., Manusama, R., Timmermans, C. C., Ghaye, B., Philippens, S., Wellens, H. J. J., & Rodriguez, L. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.08.065 · Cited by 27
Pokushalov, E. A., Romanov, A. B., Chernyavskiy, A. М., CORBUCCI, G., Алексеевна, П. И., Карева, Ю. Е., & Karaskov, A. M. (2011) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2010.11.083 · Cited by 29
Yamada, T., Yoshida, N., Murakami, Y., Okada, T., Yoshida, Y., Muto, M., Inden, Y., & Murohara, T. (2009) · Circulation Journal · doi:10.1253/circj.cj-09-0158 · Cited by 27
Ajijola, O. A., Aksu, T., Arora, R., Biaggioni, I., Chen, P., Ferrari, G. M. D., Dusi, V., Fudim, M., Goldberger, J. J., Green, A. L., et al. (2025) · The Journal of Physiology · doi:10.1113/jp284741 · Cited by 31
Discontinuation of Oral Anticoagulation After Successful Atrial Fibrillation Ablation
Iwawaki, T., Yanagisawa, S., Inden, Y., Hiramatsu, K., Yamauchi, R., Miyamae, K., Miyazawa, H., Goto, T., Kondo, S., Tachi, M., et al. (2025) · JAMA Network Open · doi:10.1001/jamanetworkopen.2025.1320 · Cited by 26
Optical signatures of radiofrequency ablation in biological tissues
Lanka, P., Francis, K. J., Kruit, H., Farina, A., Cubeddu, R., Sekar, S. K. V., Manohar, S., & Pifferi, A. (2021) · Scientific Reports · doi:10.1038/s41598-021-85653-0 · Cited by 26
Anticoagulation in atrial fibrillation: A contemporary viewpoint
Wyse, D. G. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.12.001 · Cited by 26
Kasirajan, V., Spradlin, E. A., Mormando, T. E., Medina, A. E., Ovadia, P., SCHWARTZMAN, D. S., Gaines, T. E., Mumtaz, M. A., Downing, S. W., & Ellenbogen, K. A. (2012) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2012.01.110 · Cited by 25
Atrial fibrillation and stroke prevention
Kakar, P., & Lip, G. Y. H. (2006) · Expert Review of Neurotherapeutics · doi:10.1586/14737175.6.10.1523 · Cited by 25
Role of Extended External Auto-Triggered Loop Recorder Monitoring for Atrial Fibrillation
Takagi, T., Miyazaki, S., Kusa, S., Taniguchi, H., Ichihara, N., Iwasawa, J., Kuroi, A., Nakamura, H., Hachiya, H., Hirao, K., et al. (2014) · Circulation Journal · doi:10.1253/circj.cj-14-0610 · Cited by 25
Arrhythmia Detection after Atrial Fibrillation Ablation: Value of Incremental Monitoring Time
Mulder, A. A. W., WIJFFELS, M. C. E. F., WEVER, E. F. D., Kelder, J. C., & Boersma, L. V. A. (2011) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2011.03202.x · Cited by 25
Kochhäuser, S., Joza, J. E., Essebag, V., Proietti, R., Koehler, J. L., Tsang, B., Wulffhart, Z. A., Pantano, A. A., Khaykin, Y., Ziegler, P., et al. (2015) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12772 · Cited by 25
Wasmer, K., Dechering, D. G., Köbe, J., Mönnig, G., Pott, C., Frommeyer, G., Lange, P. S., Kochhäuser, S., & Eckardt, L. (2016) · Clinical Research in Cardiology · doi:10.1007/s00392-016-0980-2 · Cited by 23
Catheter Ablation of Atrial Fibrillation in the Elderly
Yamada, T., & Kay, G. N. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02442.x · Cited by 23
Rhythm control and cardioversion
Sulke, N., Sayers, F., & Lip, G. Y. H. (2006) · Heart · doi:10.1136/hrt.2006.099879 · Cited by 23
Metadata
- Authors
- Hindricks, G., Piorkowski, C., Tanner, H., Kobza, R., Gerds-Li, J.-H., Carbucicchio, C., & Kottkamp, H.
- Affiliations
- Leipzig University (DE)
- From the Heart Center, Department of Electrophysiology, University of Leipzig, Leipzig, Germany.
- ORCID
- Venue
- Circulation
- Published
- 2005-07-19
- Volume
- 112
- Issue
- 3
- Pages
- 307-313
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1988904908
- Cited by
- 506
- References
- 14
- Citations by year
- 2026: 9 · 2025: 11 · 2024: 9 · 2023: 11 · 2022: 14 · 2021: 14 · 2020: 15 · 2019: 20 · 2018: 15 · 2017: 18 · 2016: 19 · 2015: 17 · 2014: 34 · 2013: 28 · 2012: 37
- FWCI
- 27.35
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- atrial fibrillation, asymptomatic atrial fibrillation, radiofrequency catheter ablation, atrial fibrillation recurrence, Holter monitoring, pulmonary vein isolation, antiarrhythmic drug failure, long-term follow-up
- MeSH terms
- Adrenergic beta-Antagonists, Adult, Aged, Anti-Arrhythmia Agents, Atrial Fibrillation, Atrial Flutter, Electrocardiography, Female, Heart Rate, Humans, Male, Middle Aged, Prospective Studies, Recurrence, Catheter Ablation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review